12 January 2018 in Healthcare Technology Letters
Verified
Journal Article
Open access
PDF file
RAReza Abbasi‐Kesbi
Reza Abbasi‐Kesbi
AVAtefeh Valipour
Atefeh Valipour
KIKhadije Imani
Khadije Imani
This Letter proposes a wireless acoustic sensor for monitoring heartbeat and respiration rate based on phonocardiogram (PCG). The developed sensor comprises a processor, a transceiver which operates at industrial, scientific and medical band and the frequency of 2.54 GHz as well as two capacitor microphones which one for recording the heartbeat and another one for respiration rate. To evaluate the precision of the presented sensor in estimating heartbeat and respiration rate, the sensor is tested on the different volunteers and the obtained results are compared with a gold standard as a reference. The results reveal that root‐mean‐square error are determined <2.27 beats/min and 0.92 breaths/min for the heartbeat and respiration rate in turn. While the standard deviation of the error is obtained <1.26 and 0.63 for heartbeat and respiration rate, respectively. Also, the sensor estimate sounds of to obtained PCG signal with sensitivity and specificity 98.1% and 98.3% in turn that make 3% improvement than previous works. The results prove that the sensor can be appropriate candidate for recognising abnormal condition in the cardiorespiratory system.

19 June 2020 in Biomedical Engineering: Applications, Basis and Communications
Verified
Journal Article
Closed access
MFMohammad Fathi
Mohammad Fathi
MNMohammadreza Nemati
Mohammadreza Nemati
SMSeyed Mohsen Mohammadi
Seyed Mohsen Mohammadi
RAReza Abbasi-Kesbi
Reza Abbasi-Kesbi
The liver is an organ in the body that plays an important role in the production and secretion of the bile. Recently, the number of liver patients are increasing because of the inhalation of harmful gases, the consumption of contaminated foods, herbs, and narcotics. Today, classification algorithms are widely used in diverse medical applications. In this paper, the classification of the liver, and non-liver patients is performed based on a support vector machine (SVM) on two datasets. To this end, the dataset is normalized and then sorted based on a proposed algorithm. After that, the feature selection is performed in order to remove the outliers and missing data. Then, 10-fold cross-validation is used for the data partition. In the end, the classification models of Linear, Quadratic and Gaussian SVM are defined and performance evaluation of the proposed method is investigated by calculation of F1-score, accuracy, and sensitivity. The results show that ILPD data have maximum accuracy, sensitivity, and F1-score of 90.9%, 89.2%, and 94%, respectively, so that a minimum improvement of 17.9% is obtained in accuracy than previous works. Additionally, the highest accuracy, sensitivity, and F1-score of BUPA data is 92.2%, 89%, and 94.3%, separately.

23 January 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RAReza Abbasi-Kesbi
Reza Abbasi-Kesbi
ANAlireza Nikfarjam
Alireza Nikfarjam
This paper presents a sensor system to estimate wrist and elbow positions developing two wearable miniature motion sensors. The developed sensors consist of a processor, a motion sensor, which comprise a 3-D accelerometer, a 3-D gyroscope, a 3-D magnetometer, as well as a transceiver operating at industrial, scientific, and medical band frequency of 2.4 GHz. By proposing a modified complementary filter alongside employing hand kinematic problem, wrist and elbow positions for three different exercises are estimated. In order to determine the accuracy and precision of the developed system, the estimated positions are compared to an optical tracking system. The obtained results illustrate root-mean-square error (RMSE) of these two exercises for positions of x-, y-, and z-axes less than 0.4, 0.59, and 0.29 cm, respectively. Also, the RMSEs of joint angles are obtained less than 1.64° in these exercises. These results show a 11%-23% improvement for estimating these positions than Madgwick filter and prove that the proposed system can be used as an accurate position feedback for monitoring hand joint movement in rehabilitation exercises.

22 November 2019 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
RAReza Abbasi-Kesbi
Reza Abbasi-Kesbi
ZAZahra Asadi
Zahra Asadi
ANAlireza Nikfarjam
Alireza Nikfarjam

14 June 2021 in Healthcare Technology Letters
Verified
Journal Article
Open access
PDF file
AAArdalan Akhavanhezaveh
Ardalan Akhavanhezaveh
RAReza Abbasi‐Kesbi
Reza Abbasi‐Kesbi
Here, a sensory motion system is developed to diagnose gait disorders using the estimation of angular variations in the knee and ankle joints. The sensory system includes two transmitter sensors and a central node, where each transmitter comprises three sensors of accelerometer, gyroscopes, and magnetometer to estimate the angular movements in the ankle and knee joints. By using a proposed filter, the angular variation is estimated in a personal computer employing the raw data of the motion sensors that are sent by the central node. The obtained results of the presented filter in comparison to an actual reference illustrate that the root mean square error is less than 1.01, 1.34, and 1.61 degrees, respectively, for the angles of ϕ and θ and ψ that illustrate an improvement of 40% than the previous work. Moreover, a quantity value is defined based on the correlation between knee and ankle angles that show the amount of correctness in gating. Thus, the proposed system can be utilized for people who suffer problems in gait and help them to improve their movements.

13 June 2023 in Healthcare Technology Letters
Verified
Journal Article
Open access
RAReza Abbasi‐Kesbi
Reza Abbasi‐Kesbi
MFMohammad Fathi
Mohammad Fathi
MNMohammad Najafi
Mohammad Najafi
ANAlireza Nikfarjam
Alireza Nikfarjam
Today, the elderly population is increasing, and there are many drawbacks for them, especially defects in their knee joints which lead to improper gait. To solve this problem, their knee joint can be replaced with knee arthroplasty. In this letter, level of improvement in the human gait before and after total knee arthroplasty (TKA) surgery is investigated using the dynamic time warping (DTW) algorithm. For this purpose, several volunteers who have problems with their knees are incorporated in a test before and after TKA surgery. Then, the data of gait analysis is collected and the data is compared with a reference using the DTW algorithm. The outcome results illustrate an improvement of 89%–97% by the proposed algorithm after TKA surgery. Therefore, patients can see improvement with high accuracy and very fast that result in more use this technique in TKR surgery.