Quantitative ultrasound techniques for assessment of bone quality have been attracting significant research attention. The axial transmission technique, which involves analysis of ultrasonic guided waves propagating along cortical bone, has been proposed for assessment of cortical bone quality. Because the frequency-dependent wavenumbers reflect the elastic parameters of the medium, high-resolution estimation of the wavenumbers is required at each frequency with low computational cost. We use an adaptive array signal processing method and propose a technique that can be used to estimate the numbers of propagation modes that exist at each frequency without the need for time-consuming calculations. An experimental study of 4-mm-thick copper and bone-mimicking plates showed that the proposed method estimated the wavenumbers accurately with estimation errors of less than 4% and a calculation time of less than 0.5 s when using a laptop computer.
The feasibility of measuring heart rate using radar echoes from a human head is demonstrated. Non‐contact measurement of vital signs using radar has been attracting much attention because such technologies can breakthrough benefits for monitoring health conditions without electrodes or wearable devices. Most existing studies have measured echoes from the torso, particularly the chest wall. However, this is difficult because of multiple interfering reflections from the complex shape of the torso and other body parts, such as limbs. The current study is the first demonstration that non‐contact heart rate measurement can be easily achieved using echoes from the human head. There are two important advantages of measurement from the human head: (i) the simple shape of the head makes an ideal radar target with only a single reflection, and (ii) the other undesired echoes can be removed using time‐gating when an ultra‐wideband radar is used. Nonetheless, because the displacement of the human head due to heart rate is small, a millimetre‐wave ultra‐wideband array radar system is developed, which is installed on the ceiling and used in the proposed measurements with participants.
8 June 2017 in Japanese Journal of Applied Physics
The axial transmission technique, which is used to estimate the phase velocity of an ultrasonic guided wave propagating along cortical bone is a promising tool for bone quality assessment. Lamb waves are ultrasonic guided waves that consist of multiple modes. The number of existing modes and the signal-to-noise ratio required for phase velocity estimation depend on the frequency of the signal. Hence, we employ an adaptive beamforming technique with spatial averaging to control signal-to-noise ratio and resolution by situating subarrays within the full array. Because the determination of the optimal size for spatial averaging is difficult, we propose a new algorithm that does not require a specific size with a new false-phase-velocity rejection technique. Using a 2.0-mm-thick copper plate, the proposed method accurately estimates phase velocity with fitting errors of 0.26 and 1.3%, as shown by simulation and experimental results, respectively. The measurement frequency ranges are more than twice wider than those measured by the conventional method.
To measure vital signs using Doppler radar, a common approach involves the use of time‐varying echo phase. To acquire these measurements, clutter rejection is necessary because clutter power is often larger than echo power. To reject static clutter, several techniques have been proposed that assume relatively large phase rotation angles because many studies assume the measurement of the upper torso, where displacement is mainly caused by respiration. However, signals from other parts of the human body are known to have smaller displacements that exhibit small phase rotation angles, which make clutter rejection more difficult. Three clutter rejection techniques for measuring small displacements are compared and their performances are investigated. Using numerical analysis, one method is demonstrated to be the most effective, even for small displacements in noisy data. The best method successfully estimates the centre with an error of −13.4 and −24.0 dB, with a signal‐to‐noise ratio of 10 and 40 dB and the range of phase rotation angles of 90° and 15°.
14 June 2016 in Japanese Journal of Applied Physics
The beam-space (BS) Capon method is an adaptive beamforming technique that reduces computational complexity. However, the complexity is not low enough for real-time imaging. Reducing the number of time-delay and transformation processes from element-space to BS signal processing is required. We propose a technique that replaces the time-delay processes by the multiplication of steering vectors and covariance matrices. In addition, we propose a compensation technique for estimating the intensity accurately. In an experimental study using a 2.0 MHz transmission frequency on a 15 × 10.4 mm2 region of interest, the first side-lobe level, the −6 dB beam width, the intensity’s estimation error, and the calculation time of the conventional method were −15 dB, 0.70 mm, 3.2 dB, and 656 ms. Those of the proposed method were −17 dB, 0.36 mm, 1.6 dB, and 81 ms, respectively. Using our method on three CPUs achieves imaging of 37 frames/s.