Guillaume Haiat

Guillaume Haiat

Auto-generated profile, based on publicly available information

Guillaume Haiat

CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, Creteil, France

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2011 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
VMVincent Mathieu
Vincent Mathieu
KFKenji Fukui
Kenji Fukui
MMMami Matsukawa
Mami Matsukawa
MKMasahiko Kawabe
Masahiko Kawabe
RVRomain Vayron
Romain Vayron
GHGuillaume Haiat
Guillaume Haiat
The evolution of implant stability in bone tissue remains difficult to assess because remodeling phenomena at the bone-implant interface are still poorly understood. The characterization of the biomechanical properties of newly formed bone tissue in the vicinity of implants at the microscopic scale is of importance in order to better understand the osseointegration process. The objective of this study is to investigate the potentiality of micro-Brillouin scattering techniques to differentiate mature and newly formed bone elastic properties following a multimodality approach using histological analysis. Coin-shaped Ti–6Al–4V implants were placed in vivo at a distance of 200 μm from rabbit tibia leveled cortical bone surface, leading to an initially empty cavity of 200 μm×4.4 mm. After 7 weeks of implantation, the bone samples were removed, fixed, dehydrated, embedded in methyl methacrylate, and sliced into 190 μm thick sections. Ultrasonic velocity measurements were performed using a micro-Brillouin scattering device within regions of interest (ROIs) of 10 μm diameter. The ROIs were located in newly formed bone tissue (within the 200 μm gap) and in mature bone tissue (in the cortical layer of the bone sample). The same section was then stained for histological analysis of the mineral content of the bone sample. The mean values of the ultrasonic velocities were equal to 4.97×10−3 m/s in newly formed bone tissue and 5.31×10−3 m/s in mature bone. Analysis of variance (p=2.42×10−4) tests revealed significant differences between the two groups of measurements. The standard deviation of the velocities was significantly higher in newly formed bone than in mature bone. Histological observations allow to confirm the accurate locations of the velocity measurements and showed a lower degree of mineralization in newly formed bone than in the mature cortical bone. The higher ultrasonic velocity measured in newly formed bone tissue compared with mature bone might be explained by the higher mineral content in mature bone, which was confirmed by histology. The heterogeneity of biomechanical properties of newly formed bone at the micrometer scale may explain the higher standard deviation of velocity measurements in newly formed bone compared with mature bone. The results demonstrate the feasibility of micro-Brillouin scattering technique to investigate the elastic properties of newly formed bone tissue.

27 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
ATAntoine Tijou
Antoine Tijou
GRGiuseppe Rosi
Giuseppe Rosi
PHPhilippe Hernigou
Philippe Hernigou
CFCharles-Henri Flouzat-Lachaniette
Charles-Henri Flouzat-Lachaniette
GHGuillaume Haïat
Guillaume Haïat
The acetabular cup (AC) implant stability is determinant for the success of cementless hip arthroplasty. A method based on the analysis of the impact force applied during the press-fit insertion of the AC implant using a hammer instrumented with a force sensor was developed to assess the AC implant stability. The aim of the present study was to investigate the performance of a method using a hammer equipped with strain sensors to retrieve the AC implant stability. Different AC implants were inserted in five bovine samples with different stability conditions leading to 57 configurations. The AC implant was impacted 16 times by the two hammers consecutively. For each impact; an indicator IS (respectively IF) determined by analyzing the time variation of the signal corresponding to the averaged strain (respectively force) obtained with the stress (respectively strain) hammer was calculated. The pull-out force F was measured for each configuration. F was significantly correlated with IS (R2 = 0.79) and IF (R2 = 0.80). The present method has the advantage of not modifying the shape of the hammer that can be sterilized easily. This study opens new paths towards the development of a decision support system to assess the AC implant stability.

23 April 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SOShigeaki Okumura
Shigeaki Okumura
Vu-Hieu NguyenVu-Hieu Nguyen
Vu-Hieu Nguyen
HTHirofumi Taki
Hirofumi Taki
GHGuillaume Haïat
Guillaume Haïat
SNSalah Naili
Salah Naili
TSToru Sato
Toru Sato
Quantitative ultrasound techniques for assessment of bone quality have been attracting significant research attention. The axial transmission technique, which involves analysis of ultrasonic guided waves propagating along cortical bone, has been proposed for assessment of cortical bone quality. Because the frequency-dependent wavenumbers reflect the elastic parameters of the medium, high-resolution estimation of the wavenumbers is required at each frequency with low computational cost. We use an adaptive array signal processing method and propose a technique that can be used to estimate the numbers of propagation modes that exist at each frequency without the need for time-consuming calculations. An experimental study of 4-mm-thick copper and bone-mimicking plates showed that the proposed method estimated the wavenumbers accurately with estimation errors of less than 4% and a calculation time of less than 0.5 s when using a laptop computer.

1 April 2018 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
ISI. Scala
I. Scala
GRGiuseppe Rosi
Giuseppe Rosi
Vu-Hieu NguyenVu-Hieu Nguyen
Vu-Hieu Nguyen
RVR. Vayron
R. Vayron
GHG. Haiat
G. Haiat
SNS. Naili
S. Naili

1 February 2024 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
LCLucas Colabella
Lucas Colabella
SNSalah Naili
Salah Naili
SCSophie Le Cann
Sophie Le Cann
GHGuillaume Haiat
Guillaume Haiat

1 November 2006 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
MSMagali Sasso
Magali Sasso
GHGuillaume Haiat
Guillaume Haiat
YYYu Yamato
Yu Yamato
SNSalah Naili
Salah Naili
MMMami Matsukawa
Mami Matsukawa