An experimental study was conducted to evaluate the anti-icing performance of NS-DBD plasma actuator under the conditions of airflow speed U = 65 m/s, ambient temperature T = −10 °C, liquid water content LWC = 0.5 g/m3, mean-volume diameter MVD = 25 μm, mainly to clarify the effect of pulse frequency and voltage amplitude of actuation on anti-icing performance. A NACA0012 airfoil model with a chord length of c = 280 mm was used in the tests. The NS-DBD plasma actuator was mounted at the front part of the airfoil. A FLIR infrared (IR) imager and CCD camera were used to record the anti-icing process of the NS-DBD plasma actuator. Two typical discharge conditions were selected for the anti-icing experiments. The first was HV-LF discharge, corresponding to discharge under higher voltage amplitude with lower pulse frequency; the second was LV-HF discharge, corresponding to discharge under lower voltage amplitude with higher pulse frequency. Results reveal that NS-DBD is a very promising method for anti-icing. With the same power consumption, the LV-HF discharge shows a better anti-icing performance compared to HV-LF discharge under the same icing conditions. In view of pulse duration and duty circle, combined with heat dissipation, it is suggested that there is a threshold frequency, corresponding to the voltage amplitude of electric actuation signal and the incoming flow condition, to achieve effective anti-icing performance.
The symmetric flying wing has a simple structure and a high lift-to-drag ratio. Due to its complicated surface design, the flow field flowing through its surface is also complex and variable, and the three-dimensional effect is obvious. In order to verify the effect of microsecond pulse plasma flow control on the symmetric flying wing, two different sizes of scaling models were selected. The discharge energy was analyzed, and the force and moment characteristics of the two flying wings and the particle image velocimetry (PIV) results on their surface flow field were compared to obtain the following conclusions. The microsecond pulse surface dielectric barrier discharge energy density is independent of the actuator length but increases with the actuation voltage. After actuation, the stall angle of attack of the small flying wing is delayed by 4°, the maximum lift coefficient is increased by 30.9%, and the drag coefficient can be reduced by 17.3%. After the large flying wing is actuated, the stall angle of attack is delayed by 4°, the maximum lift coefficient is increased by 15.1%, but the drag coefficient is increased. The test results of PIV in the flow field of different sections indicate that the stall separation on the surface of the symmetric flying wing starts first from the outer side, and then the separation area begins to appear on the inner side as the angle of attack increases.
The issue of aircraft icing poses a substantial threat to flight safety. In order to investigate more efficient anti-icing and de-icing technologies, a comparative analysis was conducted on the de-icing characteristics of three types of actuator materials under varying conditions. Initially, experimental research was undertaken to analyze the temperature traits of three actuators under ice-free conditions. Three power densities were chosen for the experiment: 0.170 W/cm2, 0.727 W/cm2, and 1.427 W/cm2. The research findings revealed distinct characteristics: plasma actuators and resistance wire actuators exhibited a strip-like high-temperature region during operation, with well-defined boundaries between the high-temperature and low-temperature zones, whereas ceramic-based semiconductor actuators showcased a uniform high-temperature region. As energy consumption rose, the thermal equilibrium temperatures of all three types tended to converge, with resistance wire actuators operating at 1.427 W/cm2, showing the highest temperature rise rate at that power density. Subsequently, experimental research was carried out on the de-icing performance of three actuators under icing conditions at a specific power density. Following 120 s of de-icing, the ice layer covering the surface of the plasma actuator completely melted, forming a cavity. Conversely, the ice layer on the ceramic-based semiconductor actuator remained partially intact in a strip shape. Ice deposits were still visible on the surface of the resistance wire actuator. This observation highlights the remarkable de-icing speed of the plasma actuator. The propulsive force of plasma generated on the fluid inside the ice layer enhances heat transfer efficiency, thereby accelerating the de-icing process of the plasma actuator at the same power density. The analysis of the de-icing performance of these three novel types of actuators establishes a robust groundwork for exploring more effective aircraft de-icing methods. Furthermore, it furnishes theoretical underpinning for the advancement of composite anti-icing and de-icing strategies.
Surface icing poses a significant risk to unmanned aerial vehicles (UAVs) and compact aerospace platforms, where limited onboard power and space require efficient anti-/de-icing surfaces. In this study, micro/nanostructures were fabricated on TC4 titanium alloy (Ti–6Al–4V) surfaces by femtosecond laser processing at different scanning speeds. The effects of scanning speed on surface morphology, wettability, static freezing, dynamic droplet behavior, and electrothermal de-icing performance were systematically investigated. Increasing the scanning speed induced nonlinear changes in microstructure height and surface roughness, while variations in ablation intensity caused nonuniform material redistribution. The surface processed at 250 mm/s showed the best anti-icing performance, with a water contact angle of 157.5 ± 0.5° and a maximum freezing delay 21.5 times longer than untreated TC4. During electrothermal de-icing, melting initiated at discrete ice–substrate contact points, forming coalesced meltwater films, while interfacial stress concentration promoted crack propagation and rapid ice detachment. Compared with untreated surfaces, ice detachment time (250 mm/s) achieved complete ice detachment at approximately 152 s, whereas ice on the untreated surface remained adhered after 270 s of continuous heating, representing a de-icing time reduction of at least 44%. These results demonstrate that combining laser-fabricated microstructures with electrothermal heating effectively reduces real ice–substrate contact, providing an enhanced anti-/de-icing strategy for lightweight, long-endurance UAV applications under identical electrical input.