An experimental study was conducted to evaluate the anti-icing performance of NS-DBD plasma actuator under the conditions of airflow speed U = 65 m/s, ambient temperature T = −10 °C, liquid water content LWC = 0.5 g/m3, mean-volume diameter MVD = 25 μm, mainly to clarify the effect of pulse frequency and voltage amplitude of actuation on anti-icing performance. A NACA0012 airfoil model with a chord length of c = 280 mm was used in the tests. The NS-DBD plasma actuator was mounted at the front part of the airfoil. A FLIR infrared (IR) imager and CCD camera were used to record the anti-icing process of the NS-DBD plasma actuator. Two typical discharge conditions were selected for the anti-icing experiments. The first was HV-LF discharge, corresponding to discharge under higher voltage amplitude with lower pulse frequency; the second was LV-HF discharge, corresponding to discharge under lower voltage amplitude with higher pulse frequency. Results reveal that NS-DBD is a very promising method for anti-icing. With the same power consumption, the LV-HF discharge shows a better anti-icing performance compared to HV-LF discharge under the same icing conditions. In view of pulse duration and duty circle, combined with heat dissipation, it is suggested that there is a threshold frequency, corresponding to the voltage amplitude of electric actuation signal and the incoming flow condition, to achieve effective anti-icing performance.
Icing and stalling on the surfaces of aircraft wings endanger flight safety. The object of this research is a nanosecond pulsed dielectric-barrier-discharge plasma actuation unit with a distributed layout, and the aerodynamic performance of aircraft wing surfaces under icing and stalling conditions is improved by changing the plasma actuation electrical parameters. Actuated under low voltage and frequency, the unit acts as a sensor to judge icing according to the change in electrical parameters. Actuated under high voltage and frequency, the discharge is severe and generates a large amount of heat, giving rise to an anti-icing unit; anti-icing is carried out through distributed-layout plasma actuation, forming modulated ice with evenly spaced distribution, which acts as a vortex generator and lessens the deterioration of aircraft aerodynamic performance under icing conditions. Actuating under high voltage and low frequency enables flow control, delays stalling, and increases lift. The different plasma-actuation functions are realized by connecting multiple units, which offers improved aircraft survivability in complex weather conditions.
In this study, a microsecond pulsed dielectric barrier discharge (μs-DBD) plasma actuator is utilized to improve the aerodynamic performance of a flying wing. The wind tunnel experiments were conducted by the μs-DBD plasma actuator at a high Reynolds number (Re = 2.61 × 106). The effects of discharge position and pulse frequency on the flow control performance were studied by force measurements. The particle image velocimetry test was used to reveal the influence of plasma actuation on the detailed velocity field at the suction side of the flying wing. Results show that plasma actuation can significantly improve the aerodynamic performance of the flying wing under high Reynolds number. The best flow control effect is obtained when the plasma actuator is mounted near stagnation point (0.1% C). There is an optimal excitation frequency (100 Hz) at Re = 2.61 × 106 (corresponding to the wind speed of 70 m/s), at which the flow instability can be effectively excited. In the optimal situation, the relative improvement of the maximum lift coefficient reaches 20.51% and the stall angle is delayed by 6°. The flow control performance is mainly achieved at the outer part of the wing because the flow separation develops gradually from the wing tip to the root. These experimental results contribute to the free flight test in the wind tunnel and the flight test in real air conditions.
The symmetric flying wing has a simple structure and a high lift-to-drag ratio. Due to its complicated surface design, the flow field flowing through its surface is also complex and variable, and the three-dimensional effect is obvious. In order to verify the effect of microsecond pulse plasma flow control on the symmetric flying wing, two different sizes of scaling models were selected. The discharge energy was analyzed, and the force and moment characteristics of the two flying wings and the particle image velocimetry (PIV) results on their surface flow field were compared to obtain the following conclusions. The microsecond pulse surface dielectric barrier discharge energy density is independent of the actuator length but increases with the actuation voltage. After actuation, the stall angle of attack of the small flying wing is delayed by 4°, the maximum lift coefficient is increased by 30.9%, and the drag coefficient can be reduced by 17.3%. After the large flying wing is actuated, the stall angle of attack is delayed by 4°, the maximum lift coefficient is increased by 15.1%, but the drag coefficient is increased. The test results of PIV in the flow field of different sections indicate that the stall separation on the surface of the symmetric flying wing starts first from the outer side, and then the separation area begins to appear on the inner side as the angle of attack increases.