Erica L King

Ms. Erica L King

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ABAhmed Bashatah
Ahmed Bashatah
BMBiswarup Mukherjee
Biswarup Mukherjee
ARAfsana Rima
Afsana Rima
SPShriniwas Patwardhan
Shriniwas Patwardhan
POPaul Otto
Paul Otto
SSSiddhartha Sikdar
Siddhartha Sikdar
Objective: Wearable ultrasound is emerging as a new paradigm of real-time imaging in freely moving humans and has wide applications from cardiovascular health monitoring to human gesture recognition. However, current wearable ultrasound devices have typically employed pulse-echo imaging which requires high excitation voltages and sampling rates, posing safety risks, and requiring specialized hardware. Our objective was to develop and evaluate a wearable ultrasound system based on time delay spectrometry (TDS) that utilizes low-voltage excitation and significantly simplified instrumentation. Methods: We developed a TDS-based ultrasound system that utilizes continuous, frequency-modulated sweeps at low excitation voltages. By mixing the transmit and receive signals, the system digitizes the ultrasound signal at audio frequency (kHz) sampling rates. Wearable ultrasound transducers were developed, and the system was characterized in terms of imaging performance, acoustic output, thermal characteristics, and applications in musculoskeletal imaging. Results: The prototype TDS system is capable of imaging up to 6 cm of depth with signal-to-noise ratio of up to 42 dB at a spatial resolution of 0.33 mm. Acoustic and thermal radiation measurements were within clinically safe limits for continuous ultrasound imaging. We demonstrated the ability to use a 4-channel wearable system for dynamic imaging of muscle activity. Conclusion: We developed a wearable ultrasound imaging system using TDS to mitigate challenges with pulse echo-based wearable ultrasound imaging systems. Our device is capable of high-resolution, dynamic imaging of deep-seated tissue structures and is safe for long-term use. Significance: This work paves the way for low-voltage wearable ultrasound imaging devices with significantly reduced hardware complexity.

3 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
EKErica L King
Erica L King
SPShriniwas Patwardhan
Shriniwas Patwardhan
ABAhmed Bashatah
Ahmed Bashatah
MMMeghan Magee
Meghan Magee
Margaret JonesMargaret Jones
Margaret Jones
Parag V ChitnisParag V Chitnis
Parag V Chitnis
Rehabilitation from musculoskeletal injuries focuses on reestablishing and monitoring muscle activation patterns to accurately produce force. The aim of this study is to explore the use of a novel low-powered wearable distributed Simultaneous Musculoskeletal Assessment with Real-Time Ultrasound (SMART-US) device to predict force during an isometric squat task. Participants (N = 5) performed maximum isometric squats under two medical imaging techniques; clinical musculoskeletal motion mode (m-mode) ultrasound on the dominant vastus lateralis and SMART-US sensors placed on the rectus femoris, vastus lateralis, medial hamstring, and vastus medialis. Ultrasound features were extracted, and a linear ridge regression model was used to predict ground reaction force. The performance of ultrasound features to predict measured force was tested using either the Clinical M-mode, SMART-US sensors on the vastus lateralis (SMART-US: VL), rectus femoris (SMART-US: RF), medial hamstring (SMART-US: MH), and vastus medialis (SMART-US: VMO) or utilized all four SMART-US sensors (Distributed SMART-US). Model training showed that the Clinical M-mode and the Distributed SMART-US model were both significantly different from the SMART-US: VL, SMART-US: MH, SMART-US: RF, and SMART-US: VMO models (p < 0.05). Model validation showed that the Distributed SMART-US model had an R2 of 0.80 ± 0.04 and was significantly different from SMART-US: VL but not from the Clinical M-mode model. In conclusion, a novel wearable distributed SMART-US system can predict ground reaction force using machine learning, demonstrating the feasibility of wearable ultrasound imaging for ground reaction force estimation.

9 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
EKErica L King
Erica L King
SPShriniwas Patwardhan
Shriniwas Patwardhan
ABAhmed Bashatah
Ahmed Bashatah
MMMeghan Magee
Meghan Magee
Margaret JonesMargaret Jones
Margaret Jones
Parag V ChitnisParag V Chitnis
Parag V Chitnis
Rehabilitation from musculoskeletal injuries focuses on reestablishing and monitoring muscle activation patterns to accurately produce force. The aim of this study is to explore the use of a novel low-powered wearable distributed Simultaneous Musculoskeletal Assessment with Real-Time Ultrasound (SMART-US) device to predict force during an isometric squat task. Participants (N=5) performed maximum isometric squats under two medical imaging techniques; clinical musculoskeletal motion mode (m-mode) ultrasound on the dominant vastus lateralis and SMART-US sensors placed on the rectus femoris, vastus lateralis, medial hamstring, and vastus medialis. Ultrasound features were extracted, and a linear ridge regression model was used to predict ground reaction force. The performance of ultrasound features to predict measured force was tested using either the Clinical M-mode, SMART-US sensors on the vastus lateralis (SMART-US: VL), rectus femoris (SMART-US: RF), medial hamstring (SMART-US: MH), and vastus medialis (SMART-US: VMO) or utilized all four SMART-US sensors (Distributed SMART-US). Model training showed that the Clinical M-mode and the Distributed SMART-US model were both significantly different from the SMART-US: VL, SMART-US: MH, SMART-US:RF, and SMART-US:VMO models (p<0.05). Model validation showed that the Distributed SMART-US model had an R2 of 0.80 ±0.04 and was significantly different from SMART-US: VL but not from the Clinical M-mode model. In conclusion, a novel wearable distributed SMART-US system can predict ground reaction force using machine learning, demonstrating the feasibility of wearable ultrasound imaging for ground reaction force estimation.

6 December 2024 in Sports
Verified
Journal Article
Open access
PDF file
Faith BrownFaith Brown
Faith Brown
JFJennifer Fields
Jennifer Fields
AJAndrew - Jagim
Andrew - Jagim
EKErica L King
Erica L King
RBRobert E. Baker
Robert E. Baker
Margaret JonesMargaret Jones
Margaret Jones
External (EL) and internal (IL) load are commonly used methods used to quantify training load in team sports. Playing time and playing position may influence the training loads for specific athletes throughout a season. The purpose of the current study was to evaluate the effect of athlete playing status and individual in-season practices on EL and IL across a collegiate women’s basketball season. Female basketball athletes were classified as high-minute (HMA; ≥15 min/game) or low-minute (LMA; <15 min/game) and wore microsensors during 53 practices for a total of 583 data points. EL was obtained via an inertial measurement unit (IMU) device that contained a triaxial accelerometer to obtain three-dimensional positioning data. IL and strength training (ST) load were determined via session rating of perceived exertion (sRPE) to create a daily summated value. Descriptive statistics indicate that athletes experienced individual differences in EL, ST, and IL throughout the season. A growth model showed that HMAs experienced higher EL than LMAs at the start of the season for practices (90.21 AU). Across all athletes, IL increased across the season (40.11 AU) and for each 1 unit of change in EL, IL increased by 1.04 AU. Repeated measures correlations identified a large relationship between IL and EL (r = 0.51, p < 0.001). A location-scale model indicated that the within-person variability of IL across all athletes was 3.29 AU but was not due to athlete playing status. It is recommended to base in-season training on individual loads and game demands to promote athlete readiness and improved sport performance.

13 October 2026 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
ABAdam A. Burke
Adam A. Burke
NSNoelle Saine
Noelle Saine
EKErica L King
Erica L King
JFJennifer Fields
Jennifer Fields
AJAndrew - Jagim
Andrew - Jagim
Margaret JonesMargaret Jones
Margaret Jones
Burke, AA, Saine, ND, King, EL, Fields, JB, Jagim, AR, Miller, AD, Green, BC, and Jones, MT. Assessment of countermovement jump performance in collegiate baseball athletes: A longitudinal multilevel modeling approach. J Strength Cond Res XX(X): 000–000, 2026—Given the length and demands of the collegiate baseball season, monitoring body composition and neuromuscular performance can help optimize load management and athlete readiness. Relationships between body composition and countermovement jump (CMJ) performance were examined during a competitive baseball season. Pitchers and position athletes ( n = 32) completed pre- and post-season dual-energy x-ray absorptiometry scans and weekly CMJ testing. Countermovement jump variables included jump height (JH), reactive strength index modified, peak braking force (PBF), and peak propulsive force (PPF), all normalized to body mass (BM). Repeated-measures multivariate analyses of variance assessed time and group (pitcher vs. position player) effects. Pearson correlations evaluated associations between CMJ and body composition metrics, and hierarchical linear models (HLMs) quantified individual performance trajectories. Preseason-to-postseason reductions were observed in BM, fat free mass (FFM), JH, and PPF ( p < 0.05). Peak braking force declined in pitchers, while PPF declined across both groups. Body composition showed negligible correlations with CMJ metrics, except for a moderately negative correlation between JH and body fat percentage ( r = −0.52, p < 0.001). Hierarchical linear models revealed curvilinear CMJ performance trajectories ( p < 0.001), with position players exhibiting lower PBF throughout the season ( β = −1.47, p = 0.03) and preseason FFM positively predicting PBF ( β = 0.118, p = 0.010). Findings suggest that reductions in lean mass and force output occur across the competitive season and vary by position. It is recommended that practitioners implement routine longitudinal monitoring when using CMJ and body composition assessments, as they may assist in detecting neuromuscular fatigue and guide individualized training interventions.

2 August 2026 in medRxiv
Verified
Preprint
Open access
PDF file
EKErica L King
Erica L King
CDConnor Delaney
Connor Delaney
MLMorgan A. Lamarre
Morgan A. Lamarre
AQAmad Qureshi
Amad Qureshi
SSSiddhartha Sikdar
Siddhartha Sikdar
PCParag V. Chitnis
Parag V. Chitnis
Musculoskeletal ultrasound (MSK-US) enables real-time imaging of muscle structure and function, and wearable ultrasound (WUS) has extended this capability to dynamic movement tasks. Accurate tracking of muscle fascia displacement in M-mode WUS images is essential for quantifying muscle function, yet the relative performance of existing fascia-tracking algorithms remains uncharacterized. This study directly compares five fascia-tracking algorithms: Maximum Pixel Intensity (MPI), Muscle Boundary Tracking Algorithm (MBTA), Principal Component Analysis (PCA), Composite-Factorization PCA (CF-PCA), and U-Net segmentation, against expert-annotated ground truth to identify which approach best supports wearable muscle-monitoring applications. A total of 572 M-mode ultrasound images were collected during isometric quadricep activations (QA) and squats (SQ) using a multi-site WUS system with transducers positioned on the vastus lateralis (VL), rectus femoris (RF), and vastus medialis oblique (VMO). Fascia tracking using U-Net segmentation exhibited the lowest mean absolute error (median QA=0.57, median SQ=1.22; p<0.05), functional range not statistically different from expert traces (QA p=0.33; SQ p=1) and the most accurate estimates of functional error (median QA=-0.21; median SQ=-0.65; p<0.05). PCA-based methods demonstrated the highest correlation with the expert traces (PCA median QA=0.88; CF-PCA median QA=0.88; PCA median SQ=0.78; CF-PCA median SQ=0.75; p<0.005), reflecting superior tracking of relative contraction patterns. These results indicate U-Net segmentation is best suited for applications requiring precise fascia-depth estimation when labeled training data are available, while PCA-based methods are preferable for tracking relative contraction patterns without supervised training, informing algorithm selection for wearable neuromuscular monitoring in clinical and performance settings.