Paul J. Rullkoetter

Prof. Paul J. Rullkoetter


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2006 in Journal of Biomechanics
Verified
Journal Article
Closed access
LKLucy A. Knight
Lucy A. Knight
SPSaikat Pal
Saikat Pal
JCJohn C. Coleman
John C. Coleman
FBFred Bronson
Fred Bronson
HHHani Haider
Hani Haider
PRPaul J. Rullkoetter
Paul J. Rullkoetter

1 July 2010 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
JHJason P. Halloran
Jason P. Halloran
CCChadd W. Clary
Chadd W. Clary
LMLorin P. Maletsky
Lorin P. Maletsky
MTMark Taylor
Mark Taylor
APAnthony J. Petrella
Anthony J. Petrella
PRPaul J. Rullkoetter
Paul J. Rullkoetter
Evaluating total knee replacement kinematics and contact pressure distributions is an important element of preclinical assessment of implant designs. Although physical testing is essential in the evaluation process, validated computational models can augment these experiments and efficiently evaluate perturbations of the design or surgical variables. The objective of the present study was to perform an initial kinematic verification of a dynamic finite element model of the Kansas knee simulator by comparing predicted tibio- and patellofemoral kinematics with experimental measurements during force-controlled gait simulation. A current semiconstrained, cruciate-retaining, fixed-bearing implant mounted in aluminum fixtures was utilized. An explicit finite element model of the simulator was developed from measured physical properties of the machine, and loading conditions were created from the measured experimental feedback data. The explicit finite element model allows both rigid body and fully deformable solutions to be chosen based on the application of interest. Six degrees-of-freedom kinematics were compared for both tibio- and patellofemoral joints during gait loading, with an average root mean square (rms) translational error of 1.1 mm and rotational rms error of 1.3 deg. Model sensitivity to interface friction and damping present in the experimental joints was also evaluated and served as a secondary goal of this paper. Modifying the metal-polyethylene coefficient of friction from 0.1 to 0.01 varied the patellar flexion-extension and tibiofemoral anterior-posterior predictions by 7 deg and 2 mm, respectively, while other kinematic outputs were largely insensitive.

15 April 2009 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
MBMark A. Baldwin
Mark A. Baldwin
PLPeter J. Laz
Peter J. Laz
JSJoshua Q. Stowe
Joshua Q. Stowe
PRPaul J. Rullkoetter
Paul J. Rullkoetter
Verified and efficient representations of knee ligamentous constraints are essential to forward-dynamic models for prediction of knee mechanics. The objectives of this study were to develop an efficient probabilistic representation of knee ligamentous constraint using the advanced mean value (AMV) probabilistic approach, and to compare the AMV representation with the gold standard Monte Carlo (MC) approach. Specifically, the effects of inherent uncertainty in ligament stiffness, reference strain and attachment site locations on joint constraint were assessed. An explicit finite element model of the knee was evaluated under a series of anterior–posterior (AP) and internal–external (IE) loading at full extension and 90° flexion. Distributions of AP and IE laxity were predicted using experimentally-based levels of ligament parameter variability. Importance factors identified the critical properties affecting the predicted bounds, and agreed with reported ligament recruitment. The AMV method agreed closely with MC results with a four-fold reduction in computation time.

1 December 2010 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
CFClare K. Fitzpatrick
Clare K. Fitzpatrick
MBMark A. Baldwin
Mark A. Baldwin
PRPaul J. Rullkoetter
Paul J. Rullkoetter
Finite element methods have been applied to evaluate in vivo joint behavior, new devices, and surgical techniques but have typically been applied to a small or single subject cohort. Anatomic variability necessitates the use of many subject-specific models or probabilistic methods in order to adequately evaluate a device or procedure for a population. However, a fully deformable finite element model can be computationally expensive, prohibiting large multisubject or probabilistic analyses. The aim of this study was to develop a group of subject-specific models of the patellofemoral joint and evaluate trade-offs in analysis time and accuracy with fully deformable and rigid body articular cartilage representations. Finite element models of eight subjects were used to tune a pressure-overclosure relationship during a simulated deep flexion cycle. Patellofemoral kinematics and contact mechanics were evaluated and compared between a fully deformable and a rigid body analysis. Additional eight subjects were used to determine the validity of the rigid body pressure-overclosure relationship as a subject-independent parameter. There was good agreement in predicted kinematics and contact mechanics between deformable and rigid analyses for both the tuned and test groups. Root mean square differences in kinematics were less than 0.5 deg and 0.2 mm for both groups throughout flexion. Differences in contact area and peak and average contact pressures averaged 5.4%, 9.6%, and 3.8%, respectively, for the tuned group and 6.9%, 13.1%, and 6.4%, respectively, for the test group, with no significant differences between the two groups. There was a 95% reduction in computational time with the rigid body analysis as compared with the deformable analysis. The tuned pressure-overclosure relationship derived from the patellofemoral analysis was also applied to tibiofemoral (TF) articular cartilage in a group of eight subjects. Differences in contact area and peak and average contact pressures averaged 8.3%, 11.2%, and 5.7% between rigid and deformable analyses in the tibiofemoral joint. As statistical, probabilistic, and optimization techniques can require hundreds to thousands of analyses, a viable platform is crucial to component evaluation or clinical applications. The computationally efficient rigid body platform described in this study may be integrated with statistical and probabilistic methods and has potential clinical application in understanding in vivo joint mechanics on a subject-specific or population basis.

30 December 2005 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
JPJanaki R. Penmetsa
Janaki R. Penmetsa
PLPeter J. Laz
Peter J. Laz
APAnthony J. Petrella
Anthony J. Petrella
PRPaul J. Rullkoetter
Paul J. Rullkoetter
After total hip arthroplasty (THA), polyethylene acetabular liner creep occurs quickly and serves to increases head–liner contact area and decrease contact pressures. What effect these early changes in contact mechanics will have on the wear behavior of the articulation remains unclear, and hence, selection or modification of polyethylene materials for optimal creep and wear performance is impossible. The objective of this study was to determine the influence of polyethylene creep behavior on volumetric wear and linear creep and wear penetration during simulated gait loading conditions. A finite element model of THA articulation was developed, and simultaneous numerical creep and wear simulation was performed to 10 million gait cycles with three levels of polyethylene creep behavior. Long‐term volumetric wear and penetration were surprisingly unaffected by the polyethylene creep behavior due to the competing decrease in contact pressures coupled with increased contact area. In addition, variation in contact mechanics with the creep levels studied was only noteworthy in the initial postoperative period; after 1 million gait cycles, peak contact pressures and areas were within 13% regardless of the creep material behavior selected. Femoral head size had considerable impact on wear and penetration, while liner thickness primarily affected only early penetration. These results suggest that polyethylene creep behavior plays a major role in early penetration, but has little influence on the more important long‐term volumetric wear. © 2005 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 24:422–427, 2006

9 September 2010 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
CFClare K. Fitzpatrick
Clare K. Fitzpatrick
MBMark A. Baldwin
Mark A. Baldwin
AAAzhar A. Ali
Azhar A. Ali
PLPeter J. Laz
Peter J. Laz
PRPaul J. Rullkoetter
Paul J. Rullkoetter