Mark Taylor

Prof. Mark Taylor

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2002 in Journal of Biomechanics
Verified
Journal Article
Closed access
AGA.C. Godest
A.C. Godest
MBM. Beaugonin
M. Beaugonin
EHE. Haug
E. Haug
MTMark Taylor
Mark Taylor
PGP.J. Gregson
P.J. Gregson

1 March 1996 in Medical Engineering & Physics
Verified
Journal Article
Closed access
MTMark Taylor
Mark Taylor
KTK.E. Tanner
K.E. Tanner
MFM.A.R. Freeman
M.A.R. Freeman
AYA.L. Yettram
A.L. Yettram
The aim of this research was to test the hypothesis that the intact femur is loaded predominately in compression. The study was composed of two parts: a finite element analysis of the intact femur to assess if a compressive stress distribution could be achieved in the diaphyseal region of the femur using physiological muscle and joint contact forces; a simple radiological study to assess the in vivo deflections of the femur during one legged stance. The results of this investigation strongly support the hypothesis that the femur is loaded primarily in compression, and not bending as previously thought. The finite element analysis demonstrated that a compressive stress distribution in the diaphyseal femur can be achieved, producing a stress distribution which appears to be consistent with the femoral cross-sectional geometry. The finite element analysis also predicted that for a compressive load case there would be negligible deflections of the femoral head. The radiological study confirmed this, with no measurable in vivo deflection of the femur occurring during one legged stance.

1 March 2015 in Journal of Biomechanics
Verified
Journal Article
Open access
MTMark Taylor
Mark Taylor
PPPatrick J. Prendergast
Patrick J. Prendergast
Finite element has been used for more than four decades to study and evaluate the mechanical behaviour total joint replacements. In Huiskes seminal paper "Failed innovation in total hip replacement: diagnosis and proposals for a cure", finite element modelling was one of the potential cures to avoid poorly performing designs reaching the market place. The size and sophistication of models has increased significantly since that paper and a range of techniques are available from predicting the initial mechanical environment through to advanced adaptive simulations including bone adaptation, tissue differentiation, damage accumulation and wear. However, are we any closer to FE becoming an effective screening tool for new devices? This review contains a critical analysis of currently available finite element modelling techniques including (i) development of the basic model, the application of appropriate material properties, loading and boundary conditions, (ii) describing the initial mechanical environment of the bone-implant system, (iii) capturing the time dependent behaviour in adaptive simulations, (iv) the design and implementation of computer based experiments and (v) determining suitable performance metrics. The development of the underlying tools and techniques appears to have plateaued and further advances appear to be limited either by a lack of data to populate the models or the need to better understand the fundamentals of the mechanical and biological processes. There has been progress in the design of computer based experiments. Historically, FE has been used in a similar way to in vitro tests, by running only a limited set of analyses, typically of a single bone segment or joint under idealised conditions. The power of finite element is the ability to run multiple simulations and explore the performance of a device under a variety of conditions. There has been increasing usage of design of experiments, probabilistic techniques and more recently population based modelling to account for patient and surgical variability. In order to have effective screening methods, we need to continue to develop these approaches to examine the behaviour and performance of total joint replacements and benchmark them for devices with known clinical performance. Finite element will increasingly be used in the design, development and pre-clinical testing of total joint replacements. However, simulations must include holistic, closely corroborated, multi-domain analyses which account for real world variability.

1 July 2018 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
JBJ.S. Bahl
J.S. Bahl
MNM.J. Nelson
M.J. Nelson
MTMark Taylor
Mark Taylor
Lucian Bogdan SolomonLucian Bogdan Solomon
Lucian Bogdan Solomon
JAJohn Arnold
John Arnold
DTDominic Thewlis
Dominic Thewlis

1 April 2007 in Biomaterials
Verified
Journal Article
Closed access
BSBram G. Sengers
Bram G. Sengers
MTMark Taylor
Mark Taylor
CPColin P. Please
Colin P. Please
RORichard Oreffo
Richard Oreffo

3 November 2006 in Journal of Biomechanics
Verified
Journal Article
Closed access
LKLucy A. Knight
Lucy A. Knight
SPSaikat Pal
Saikat Pal
JCJohn C. Coleman
John C. Coleman
FBFred Bronson
Fred Bronson
HHHani Haider
Hani Haider
PRPaul J. Rullkoetter
Paul J. Rullkoetter