TianQin is a future space-based gravitational wave (GW) observatory targeting the frequency window of 10−4–1 Hz. A large variety of GW sources are expected in this frequency band, including the merger of massive black hole binaries, the inspiral of extreme/intermediate mass ratio systems, stellar-mass black hole binaries, Galactic compact binaries, and so on. TianQin will consist of three Earth orbiting satellites on nearly identical orbits with orbital radii of about 105 km. The satellites will form a normal triangle constellation whose plane is nearly perpendicular to the ecliptic plane. The TianQin project has been progressing smoothly following the ‘0123’ technology roadmap. In step ‘0’, the TianQin laser ranging station has been constructed and it has successfully ranged to all the five retro-reflectors on the Moon. In step ‘1’, the drag-free control technology has been tested and demonstrated using the TianQin-1 satellite. In step ‘2’, the inter-satellite laser interferometry technology will be tested using the pair of TianQin-2 satellites. The TianQin-2 mission has been officially approved and the satellites will be launched around 2026. In step ‘3’, i.e. the TianQin-3 mission, three identical satellites will be launched around 2035 to form the space-based GW detector, TianQin, and to start GW detection in space.
As an integral component of the laser interferometry measurement system, the tilt-to-length (TTL) coupling noise inside the telescope stands out as a critical noise factor that requires meticulous consideration. In the TianQin project, the non-geometric TTL-coupled noise inside the telescope should be less than 0.22 pm/Hz1/2. Additionally, the wavefront aberration RMS at the small pupil of the telescope needs to be better than 0.0065 λ. These requirements set for the telescope are exceptionally stringent. To address this challenge, this study aims to relax the wavefront aberration requirements by mitigating non-geometric TTL coupling noise, while ensuring the non-geometric TTL coupling noise remains below 0.22 pm/Hz1/2. By controlling the coupling aberration proportion, the wavefront aberration RMS at the small pupil of the telescope can be relaxed to 0.014 λ. Alternatively, optimizing the Gaussian beam waist radius can relax the wavefront aberration RMS to 0.016 λ. By simultaneously utilizing two optimization methods, the wavefront aberration at the small pupil of the telescope can be reduced to 0.033 λ, resulting in an impressive success rate of 91.15% in meeting the noise requirements.
Tilt-to-length (TTL) coupling noise is one of the main noise sources that affect space gravitational wave detection, and the Tianqin project requires that the internal TTL coupling noise of the telescope used be less than 0.4 pm/Hz1/2 within the frequency band from 0.1 mHz to 1 Hz. In order to design a telescope that meets the requirements of TTL coupling noise and carry out preliminary error allocation research, it is necessary to analyze and calculate the TTL coupling noise, and then guide the design and optimization of the telescope system. This paper establishes a computational analysis model for the non-geometric TTL coupling noise inside the telescope using the first 36-order edge Zernike polynomials. A method was proposed to reduce the internal TTL coupling noise of the telescope by reducing the proportion of sensitive aberrations caused by non-geometric TTL coupling noise. Simulation results show that, with the RMS value of wavefront aberration at the telescope exit pupil unchanged, reducing the proportion of sensitive aberrations at the telescope exit pupil can effectively reduce the internal TTL coupling noise of the telescope. By optimizing the telescope optical system to reduce the proportion of noise-sensitive aberrations, the non-geometric TTL coupling noise inside the telescope has been reduced from 0.34 pm/Hz1/2 @ 0.1 mHz ∼ 1 Hz to 0.25 pm/Hz1/2. This result can provide some guidance for the design of telescope optics based on the suppression of internal TTL coupling noise in the telescope.
The telescope is vital for accurate gravitational wave detection in the TianQin project. It must meet criteria like a geometric tilt-to-length (TTL) coupling noise coefficient≤0.02√2nm/µrad and wavefront RMS≤λ/30. Analyzing the pupil aberration’s impact on geometric TTL noise, we devised an optimization method using the chief ray spot diagram’s standard deviation. Implementing this in Zemax with a ZPL macro, we designed an optical system meeting TianQin’s requirements. The system has a maximum geometric TTL noise coefficient of 0.0250 nm/µrad over the science FOV and a wavefront RMS of 0.0111λ, confirming the method’s feasibility.
20 October 2023 in Measurement Science and Technology
The misalignment between the geometric center and rotation center in fast steering mirrors (FSMs) poses a challenge for space-borne gravitational wave detection, as it results in geometric tilt-to-length (TTL) coupling noise. To address this issue, we have proposed a FSM structure that exhibits ultra-low geometric TTL coupling noise. The geometric TTL coupling noise is analyzed and evaluated strictly considering the FSM non-ideal tilt of the plane and the center shift characteristic of cartwheel flexure hinges under a small rotational angle. Compared to traditional FSM designs, our new design offers superior noise suppression capabilities and is capable of meeting the stringent piston effect noise requirements of 0.2 in the frequency band of under ideal conditions.
Gravitational wave telescope place extremely high demands on structural thermal deformation, making material selection a critical issue. Carbon fiber reinforced polymer (CFRP) is an ideal choice for the support structure of telescope due to its low coefficient of thermal expansion (CTE) and designable properties. However, current research on the optimization of the CTE of CFRP is scarce, and conventional methods struggle to find layups that meet the requirements. In this paper, an unconventional layup optimization method is proposed to solve this problem. Initially defining the characteristics of the telescope structure and using different layup material for the main and side support rods to minimize thermal deformation. Subsequently, the NSGA-II algorithm is used to optimize the layups which are divided into conventional and unconventional layups. Specimens are then produced from these results and tested to assess the impact of processing errors on practical applications. The results demonstrate that the optimized CFRP meet the CTE requirements and, when applied to the structure, significantly reduces the thermal deformation in the eccentric direction compared to conventional designs. Additionally, a numerical analysis evaluates the effect of ply orientation errors on the performance of unconventional layups, discussing the method's limitations within these contexts.