19 March 2024 in Optics Express
As an integral component of the laser interferometry measurement system, the tilt-to-length (TTL) coupling noise inside the telescope stands out as a critical noise factor that requires meticulous consideration. In the TianQin project, the non-geometric TTL-coupled noise inside the telescope should be less than 0.22 pm/Hz1/2. Additionally, the wavefront aberration RMS at the small pupil of the telescope needs to be better than 0.0065 λ. These requirements set for the telescope are exceptionally stringent. To address this challenge, this study aims to relax the wavefront aberration requirements by mitigating non-geometric TTL coupling noise, while ensuring the non-geometric TTL coupling noise remains below 0.22 pm/Hz1/2. By controlling the coupling aberration proportion, the wavefront aberration RMS at the small pupil of the telescope can be relaxed to 0.014 λ. Alternatively, optimizing the Gaussian beam waist radius can relax the wavefront aberration RMS to 0.016 λ. By simultaneously utilizing two optimization methods, the wavefront aberration at the small pupil of the telescope can be reduced to 0.033 λ, resulting in an impressive success rate of 91.15% in meeting the noise requirements.
22 February 2024 in Applied Optics
The telescope is vital for accurate gravitational wave detection in the TianQin project. It must meet criteria like a geometric tilt-to-length (TTL) coupling noise coefficient≤0.02√2nm/µrad and wavefront RMS≤λ/30. Analyzing the pupil aberration’s impact on geometric TTL noise, we devised an optimization method using the chief ray spot diagram’s standard deviation. Implementing this in Zemax with a ZPL macro, we designed an optical system meeting TianQin’s requirements. The system has a maximum geometric TTL noise coefficient of 0.0250 nm/µrad over the science FOV and a wavefront RMS of 0.0111λ, confirming the method’s feasibility.
12 February 2024 in Applied Optics
The optical path length stability of the off-axis four-reflection telescope is one of the key technical indicators for the TianQin gravitational wave detection system. In the mHz observation band, the telescope must exhibit an optical path length stability of 0.4pm/Hz1/2. As a feasible solution, the optical path length stability measurement of the off-axis four-reflection telescope based on the Pound–Drever–Hall (PDH) technique imposes stringent requirements on the alignment of the off-axis resonant cavity (ORC). Taking the off-axis two-reflection prototype as the research object, we propose a Monte Carlo analysis-based method for ORC alignment precision analysis. By considering misalignment as an intermediate function, we establish a relationship between the coupling efficiency of the ORC and the wavefront aberration of the telescope. The research results show that by considering the combined effects of multiple misalignment couplings of the primary and secondary mirrors, when the detected telescope wavefront aberration is better than 0.068λ (λ=1064nm) with a probability of 98%, the ORC coupling efficiency can achieve greater than 40% with a probability of 97.13%, which can be used as the main reference indicator for system misalignment analysis. This method simplifies the alignment difficulty of the target under test and can provide alignment reference for subsequent resonant cavities with internal off-axis telescopes.
4 June 2024 in Applied Optics
As an important component of the gravitational wave detection interferometric measurement system, the telescope’s main function is to receive and emit laser signals. Under the influence of in-orbit environmental disturbances, the telescope will experience structural deformation. This can result in changes in the propagation path of the laser within the telescope, which in turn affects the ranging accuracy. Therefore, it is necessary to suppress the optical path variation caused by the deformation of the telescope during the design phase of the telescope structure. In this paper, a calculation and analysis model of the non-geometric optical path length variation within the telescope was established using the first 36 orders of the fringe Zernike polynomials. The derivation of the geometric optical path variation within the telescope was completed, and the optical system error analysis was performed based on the internal optical path variation of the telescope as an evaluation index. The primary mirror components that meet the detection requirements were designed. The results showed that for the off-axis four-mirror optical system, under the same disturbance, the geometric optical path variation caused by the rigid displacement of the primary mirror dominates. When the environmental temperature stability is 2.8×10−6K⋅Hz−1/2 @0.1 Hz, the system’s optical path stability is reduced from the original 8.5pm⋅Hz−1/2 @0.1 Hz to 0.45pm⋅Hz−1/2 @0.1 Hz.
9 April 2025 in Optics Express
The structural stability of the optical system in an off-axis four-mirror space telescope is critical to maintaining its optical performance and avoiding potential system failure. Structural deformation can cause variations of the optical path within the telescope, with different degrees of freedom (DOFs) of mirror displacement exerting varying degrees of influence on the optical path. This study develops a model to analyze the impact of multi-DOF rigid body displacements of mirrors on the optical path and predicts the sensitivity of each DOF. The findings are validated through simulations using Zemax, identifying the sensitive DOFs, which are further confirmed through experiments. The results reveal that the effects of displacements vary across different mirrors and DOFs. For instance, in the primary mirror, translation along the Z-axis, translation along the Y-axis, and rotation around the X-axis have the most significant impacts on the optical path and are identified as sensitive directions. In the rotation direction around the X axis, the optical path variation caused by the primary mirror’s displacement is significantly greater than that of the secondary mirror. These sensitive directions should receive special attention during the design and testing phases of the telescope. This research provides essential technical support and methodological references for ultra-high-precision multi-DOF structural stability measurements in gravitational wave telescopes. It also offers valuable guidance for the design of ultra-stable structures.
1 February 2025 in AIP Advances
The effects of the coupling coefficients on the reflected field and the error signal under various misalignments and near-axis conditions are analyzed, and some basic features of the error signal are investigated. According to the definition of traditional coupling efficiency, the relationship between the discriminator slope and the coupling efficiency under the condition of misalignment of waist radius and waist position is derived. The experimental results are in good agreement with the theoretical simulations, the error of the results measured by transmission is within 2%, and the error of the results measured by reflection is within 4%. It shows that the discriminator slope has different expressions under different approximation conditions. On this basis, a fast and simple method for measuring the discriminator slope is found.