Stuart  Cogan

Prof. Dr. Stuart Cogan

Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2016 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
SCStuart Cogan
Stuart Cogan
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
CWCristin G Welle
Cristin G Welle
PTPavel Takmakov
Pavel Takmakov
Objective . Recent initiatives in bioelectronic modulation of the nervous system by the NIH (SPARC), DARPA (ElectRx, SUBNETS) and the GlaxoSmithKline Bioelectronic Medicines effort are ushering in a new era of therapeutic electrical stimulation. These novel therapies are prompting a re-evaluation of established electrical thresholds for stimulation-induced tissue damage. Approach . In this review, we explore what is known and unknown in published literature regarding tissue damage from electrical stimulation. Main results . For macroelectrodes, the potential for tissue damage is often assessed by comparing the intensity of stimulation, characterized by the charge density and charge per phase of a stimulus pulse, with a damage threshold identified through histological evidence from in vivo experiments as described by the Shannon equation. While the Shannon equation has proved useful in assessing the likely occurrence of tissue damage, the analysis is limited by the experimental parameters of the original studies. Tissue damage is influenced by factors not explicitly incorporated into the Shannon equation, including pulse frequency, duty cycle, current density, and electrode size. Microelectrodes in particular do not follow the charge per phase and charge density co-dependence reflected in the Shannon equation. The relevance of these factors to tissue damage is framed in the context of available reports from modeling and in vivo studies. Significance . It is apparent that emerging applications, especially with microelectrodes, will require clinical charge densities that exceed traditional damage thresholds. Experimental data show that stimulation at higher charge densities can be achieved without causing tissue damage, suggesting that safety parameters for microelectrodes might be distinct from those defined for macroelectrodes. However, these increased charge densities may need to be justified by bench, non-clinical or clinical testing to provide evidence of device safety.

8 January 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
FDFelix Deku
Felix Deku
YCYarden Cohen
Yarden Cohen
Alexandra Joshi-ImreAlexandra Joshi-Imre
Alexandra Joshi-Imre
AKAswini Kanneganti
Aswini Kanneganti
TGTimothy J Gardner
Timothy J Gardner
SCStuart Cogan
Stuart Cogan
Objective . Foreign body response to indwelling cortical microelectrodes limits the reliability of neural stimulation and recording, particularly for extended chronic applications in behaving animals. The extent to which this response compromises the chronic stability of neural devices depends on many factors including the materials used in the electrode construction, the size, and geometry of the indwelling structure. Here, we report on the development of microelectrode arrays (MEAs) based on amorphous silicon carbide (a-SiC). Approach . This technology utilizes a-SiC for its chronic stability and employs semiconductor manufacturing processes to create MEAs with small shank dimensions. The a-SiC films were deposited by plasma enhanced chemical vapor deposition and patterned by thin-film photolithographic techniques. To improve stimulation and recording capabilities with small contact areas, we investigated low impedance coatings on the electrode sites. The assembled devices were characterized in phosphate buffered saline for their electrochemical properties. Main results . MEAs utilizing a-SiC as both the primary structural element and encapsulation were fabricated successfully. These a-SiC MEAs had 16 penetrating shanks. Each shank has a cross-sectional area less than 60 µ m 2 and electrode sites with a geometric surface area varying from 20 to 200 µ m 2 . Electrode coatings of TiN and SIROF reduced 1 kHz electrode impedance to less than 100 kΩ from ~2.8 MΩ for 100 µ m 2 Au electrode sites and increased the charge injection capacities to values greater than 3 mC cm −2 . Finally, we demonstrated functionality by recording neural activity from basal ganglia nucleus of Zebra Finches and motor cortex of rat. Significance . The a-SiC MEAs provide a significant advancement in the development of microelectrodes that over the years has relied on silicon platforms for device manufacture. These flexible a-SiC MEAs have the potential for decreased tissue damage and reduced foreign body response. The technique is promising and has potential for clinical translation and large scale manufacturing.

6 September 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
ASAllison Stiller
Allison Stiller
BBBryan James Black
Bryan James Black
CKChristopher Kung
Christopher Kung
AAAashika Ashok
Aashika Ashok
SCStuart Cogan
Stuart Cogan
Joseph  PancrazioJoseph Pancrazio
Joseph Pancrazio
Neural implants offer solutions for a variety of clinical issues. While commercially available devices can record neural signals for short time periods, they fail to do so chronically, partially due to the sustained tissue response around the device. Our objective was to assess the correlation between device stiffness, a function of both material modulus and cross-sectional area, and the severity of immune response. Meta-analysis data were derived from nine previously published studies which reported device material and geometric properties, as well as histological outcomes. Device bending stiffness was calculated by treating the device shank as a cantilevered beam. Immune response was quantified through analysis of immunohistological images from each study, specifically looking at fluorescent markers for neuronal nuclei and astrocytes, to assess neuronal dieback and gliosis. Results demonstrate that the severity of the immune response, within the first 50 µm of the device, is highly correlated with device stiffness, as opposed to device modulus or cross-sectional area independently. In general, commercially available devices are around two to three orders of magnitude higher in stiffness than devices which induced a minimal tissue response. These results have implications for future device designs aiming to decrease chronic tissue response and achieve increased long-term functionality.

28 July 2019 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
JMJimin Maeng
Jimin Maeng
BCBitan Chakraborty
Bitan Chakraborty
NGNegar Geramifard
Negar Geramifard
TKTong Kang
Tong Kang
RRRashed T. Rihani
Rashed T. Rihani
SCStuart Cogan
Stuart Cogan

1 January 2020 in Acta Biomaterialia
Verified
Journal Article
Closed access
RARahul Atmaramani
Rahul Atmaramani
BCBitan Chakraborty
Bitan Chakraborty
RRRashed T. Rihani
Rashed T. Rihani
JUJoshua Usoro
Joshua Usoro
AHAudrey Hammack
Audrey Hammack
SCStuart Cogan
Stuart Cogan

6 April 2021 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
CLCallum Lamont
Callum Lamont
TGTimea Grego
Timea Grego
KNKambiz Nanbakhsh
Kambiz Nanbakhsh
AIAhmad Shah Idil
Ahmad Shah Idil
VGVasiliki Giagka
Vasiliki Giagka
NDNick Donaldson
Nick Donaldson
Objective. Ensuring the longevity of implantable devices is critical for their clinical usefulness. This is commonly achieved by hermetically sealing the sensitive electronics in a water impermeable housing, however, this method limits miniaturisation. Alternatively, silicone encapsulation has demonstrated long-term protection of implanted thick-film electronic devices. However, much of the current conformal packaging research is focused on more rigid coatings, such as parylene, liquid crystal polymers and novel inorganic layers. Here, we consider the potential of silicone to protect implants using thin-film technology with features 33 times smaller than thick-film counterparts. Approach. Aluminium interdigitated comb structures under plasma-enhanced chemical vapour deposited passivation (SiO x , SiO x N y , SiO x N y + SiC) were encapsulated in medical grade silicones, with a total of six passivation/silicone combinations. Samples were aged in phosphate-buffered saline at 67 ∘C for up to 694 days under a continuous ±5 V biphasic waveform. Periodic electrochemical impedance spectroscopy measurements monitored for leakage currents and degradation of the metal traces. Fourier-transform infrared spectroscopy, x-ray photoelectron spectroscopy, focused-ion-beam and scanning-electron- microscopy were employed to determine any encapsulation material changes. Main results. No silicone delamination, passivation dissolution, or metal corrosion was observed during ageing. Impedances greater than 100 GΩ were maintained between the aluminium tracks for silicone encapsulation over SiO x N y and SiC passivations. For these samples the only observed failure mode was open-circuit wire bonds. In contrast, progressive hydration of the SiO x caused its resistance to decrease by an order of magnitude. Significance. These results demonstrate silicone encapsulation offers excellent protection to thin-film conducting tracks when combined with appropriate inorganic thin films. This conclusion corresponds to previous reliability studies of silicone encapsulation in aqueous environments, but with a larger sample size. Therefore, we believe silicone encapsulation to be a realistic means of providing long-term protection for the circuits of implanted electronic medical devices.