Felix Deku

Dr. Felix Deku

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
FDFelix Deku
Felix Deku
YCYarden Cohen
Yarden Cohen
Alexandra Joshi-ImreAlexandra Joshi-Imre
Alexandra Joshi-Imre
AKAswini Kanneganti
Aswini Kanneganti
TGTimothy J Gardner
Timothy J Gardner
SCStuart Cogan
Stuart Cogan
Objective . Foreign body response to indwelling cortical microelectrodes limits the reliability of neural stimulation and recording, particularly for extended chronic applications in behaving animals. The extent to which this response compromises the chronic stability of neural devices depends on many factors including the materials used in the electrode construction, the size, and geometry of the indwelling structure. Here, we report on the development of microelectrode arrays (MEAs) based on amorphous silicon carbide (a-SiC). Approach . This technology utilizes a-SiC for its chronic stability and employs semiconductor manufacturing processes to create MEAs with small shank dimensions. The a-SiC films were deposited by plasma enhanced chemical vapor deposition and patterned by thin-film photolithographic techniques. To improve stimulation and recording capabilities with small contact areas, we investigated low impedance coatings on the electrode sites. The assembled devices were characterized in phosphate buffered saline for their electrochemical properties. Main results . MEAs utilizing a-SiC as both the primary structural element and encapsulation were fabricated successfully. These a-SiC MEAs had 16 penetrating shanks. Each shank has a cross-sectional area less than 60 µ m 2 and electrode sites with a geometric surface area varying from 20 to 200 µ m 2 . Electrode coatings of TiN and SIROF reduced 1 kHz electrode impedance to less than 100 kΩ from ~2.8 MΩ for 100 µ m 2 Au electrode sites and increased the charge injection capacities to values greater than 3 mC cm −2 . Finally, we demonstrated functionality by recording neural activity from basal ganglia nucleus of Zebra Finches and motor cortex of rat. Significance . The a-SiC MEAs provide a significant advancement in the development of microelectrodes that over the years has relied on silicon platforms for device manufacture. These flexible a-SiC MEAs have the potential for decreased tissue damage and reduced foreign body response. The technique is promising and has potential for clinical translation and large scale manufacturing.

27 October 2017 in Neuromodulation: Technology at the Neural Interface
Verified
Journal Article
Closed access
PDF file
Joseph  PancrazioJoseph Pancrazio
Joseph Pancrazio
FDFelix Deku
Felix Deku
AGAtefeh Ghazavi
Atefeh Ghazavi
ASAllison Stiller
Allison Stiller
RRRashed Rihani
Rashed Rihani
SCStuart F. Cogan
Stuart F. Cogan

8 January 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
WGWinthrop F Gillis
Winthrop F Gillis
CLCharles A Lissandrello
Charles A Lissandrello
JSJun Shen
Jun Shen
BPBenjamin Pearre
Benjamin Pearre
AMAlket Mertiri
Alket Mertiri
TGTimothy J Gardner
Timothy J Gardner
Objective . Most preparations for making neural recordings degrade over time and eventually fail due to insertion trauma and reactive tissue response. The magnitudes of these responses are thought to be related to the electrode size (specifically, the cross-sectional area), the relative stiffness of the electrode, and the degree of tissue tolerance for the material. Flexible carbon fiber ultra-microelectrodes have a much smaller cross-section than traditional electrodes and low tissue reactivity, and thus may enable improved longevity of neural recordings in the central and peripheral nervous systems. Only two carbon fiber array designs have been described previously, each with limited channel densities due to limitations of the fabrication processes or interconnect strategies. Here, we describe a method for assembling carbon fiber electrodes on a flexible polyimide substrate that is expected to facilitate the construction of high-density recording and stimulating arrays. Approach . Individual carbon fibers were aligned using an alignment tool that was 3D-printed with sub-micron resolution using direct laser writing. Indium deposition on the carbon fibers, followed by low-temperature microsoldering, provided a robust and reliable method of electrical connection to the polyimide interconnect. Main results . Spontaneous multiunit activity and stimulation-evoked compound responses with SNR >10 and >120, respectively, were recorded from a small (125 µ m) peripheral nerve. We also improved the typically poor charge injection capacity of small diameter carbon fibers by electrodepositing 100 nm-thick iridium oxide films, making the carbon fiber arrays usable for electrical stimulation as well as recording. Significance . Our innovations in fabrication technique pave the way for further miniaturization of carbon fiber ultra-microelectrode arrays. We believe these advances to be key steps to enable a shift from labor intensive, manual assembly to a more automated manufacturing process.

2 June 2018 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
FDFelix Deku
Felix Deku
Alexandra Joshi-ImreAlexandra Joshi-Imre
Alexandra Joshi-Imre
AMAlket Mertiri
Alket Mertiri
TGTimothy J. Gardner
Timothy J. Gardner
SCStuart F. Cogan
Stuart F. Cogan
Host encapsulation decreases the ability of chronically implanted microelectrodes to record or stimulate neural activity. The degree of foreign body response is thought to depend strongly on the cross-sectional dimensions of the electrode shaft penetrating neural tissue. Microelectrodes with cellular or sub-cellular scale shaft cross-sectional dimensions, such as carbon fiber ultramicroelectrodes have been previously demonstrated to elicit minimal tissue response, but their small geometric surface area results in high electrode impedances for neural recording, and reduced charge injection capacity during current pulsing for neural stimulation. We investigated electrodeposited iridium oxide films (EIROF) on carbon fiber ultramicroelectrodes as a means of enhancing the charge injection capacity and reducing electrode impedance. EIROF coatings reduced the electrode impedance measured at 1 kHz by a factor of 10 and improved charge storage and charge injection capacities. The maximum charge injection capacity was also strongly dependent on the interpulse bias and pulse width, and reflected a potential-dependent EIROF impedance. The charge injection capacity of the EIROF-coated carbon fiber ultramicroelectrodes measured in an inorganic buffered saline model of interstitial fluid exceeded 17 mC/cm2 with appropriate biasing, allowing charge-injection at levels well above reported charge/phase thresholds for intraneural microstimulation.

20 September 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
FDFelix Deku
Felix Deku
CFChristopher L. Frewin
Christopher L. Frewin
ASAllison Stiller
Allison Stiller
YCYarden Cohen
Yarden Cohen
SASaher Aqeel
Saher Aqeel
SCStuart Cogan
Stuart Cogan
Microelectrode arrays that consistently and reliably record and stimulate neural activity under conditions of chronic implantation have so far eluded the neural interface community due to failures attributed to both biotic and abiotic mechanisms. Arrays with transverse dimensions of 10 µm or below are thought to minimize the inflammatory response; however, the reduction of implant thickness also decreases buckling thresholds for materials with low Young’s modulus. While these issues have been overcome using stiffer, thicker materials as transport shuttles during implantation, the acute damage from the use of shuttles may generate many other biotic complications. Amorphous silicon carbide (a-SiC) provides excellent electrical insulation and a large Young’s modulus, allowing the fabrication of ultrasmall arrays with increased resistance to buckling. Prototype a-SiC intracortical implants were fabricated containing 8 - 16 single shanks which had critical thicknesses of either 4 µm or 6 µm. The 6 µm thick a-SiC shanks could penetrate rat cortex without an insertion aid. Single unit recordings from SIROF-coated arrays implanted without any structural support are presented. This work demonstrates that a-SiC can provide an excellent mechanical platform for devices that penetrate cortical tissue while maintaining a critical thickness less than 10 µm.

15 October 2018 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
FDFelix Deku
Felix Deku
SMShakil Mohammed
Shakil Mohammed
Alexandra Joshi-ImreAlexandra Joshi-Imre
Alexandra Joshi-Imre
JMJimin Maeng
Jimin Maeng
VDVindhya Danda
Vindhya Danda
SCStuart F. Cogan
Stuart F. Cogan