Delphine Magnin

Dr. Delphine Magnin

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2022 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Open access
FBFilippo Brienza
Filippo Brienza
KAKorneel Van Aelst
Korneel Van Aelst
FDFrançois Devred
François Devred
DMDelphine Magnin
Delphine Magnin
BSBert F. Sels
Bert F. Sels
Damien DebeckerDamien Debecker
Damien Debecker

1 October 2019 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MNMelanie Namour
Melanie Namour
Marwan El MobadderMarwan El Mobadder
Marwan El Mobadder
DMDelphine Magnin
Delphine Magnin
APAndre Peremans
Andre Peremans
TVTim Verspecht
Tim Verspecht
EREric Rompen
Eric Rompen
Peri-implantitis (PI) is an inflammatory disease of peri-implant tissues, it represents the most frequent complication of dental implants. Evidence revealed that microorganisms play the chief role in causing PI. The purpose of our study is to evaluate the cleaning of contaminated dental implant surfaces by means of the Q-switch Nd:YAG (Neodymium-doped Yttrium Aluminum Garnet) laser and an increase in temperature at lased implant surfaces during the cleaning process. Seventy-eight implants (titanium grade 4) were used (Euroteknika, Sallanches, France). Thirty-six sterile implants and forty-two contaminated implants were collected from failed clinical implants for different reasons, independent from the study. Thirty-six contaminated implants were partially irradiated by Q-switch Nd:YAG laser (1064 nm). Six other contaminated implants were used for temperature rise evaluation. All laser irradiations were calibrated by means of a powermetter in order to evaluate the effective delivered energy. The irradiation conditions delivered per pulse on the target were effectively: energy density per pulse of 0.597 J/cm2, pick powers density of 56 mW/cm2, 270 mW per pulse with a spot diameter of 2.4 mm, and with repetition rate of 10 Hz for pulse duration of 6 ns. Irradiation was performed during a total time of 2 s in a non-contact mode at a distance of 0.5 mm from implant surfaces. The parameters were chosen according to the results of a theoretical modeling calculation of the Nd:YAG laser fluency on implant surface. Evaluation of contaminants removal showed that the cleaning of the irradiated implant surfaces was statistically similar to those of sterile implants (p-value ≤ 0.05). SEM analysis confirmed that our parameters did not alter the lased surfaces. The increase in temperature generated at lased implant surfaces during cleaning was below 1 °C. According to our findings, Q-switch Nd:YAG laser with short pulse duration in nanoseconds is able to significantly clean contaminated implant surfaces. Irradiation parameters used in our study can be considered safe for periodontal tissue.

21 January 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
JMJulie Manon
Julie Manon
RERobin Evrard
Robin Evrard
LFLies Fievé
Lies Fievé
Caroline BouzinCaroline Bouzin
Caroline Bouzin
DMDelphine Magnin
Delphine Magnin
OCOlivier Cornu
Olivier Cornu
The lack of viability of massive bone allografts for critical-size bone defect treatment remains a challenge in orthopedic surgery. The literature has reviewed the advantages of a multi-combined treatment with the synergy of an osteoconductive extracellular matrix (ECM), osteogenic stem cells, and growth factors (GFs). Questions are still open about the need for ECM components, the influence of the decellularization process on the latter, the related potential loss of function, and the necessity of using pre-differentiated cells. In order to fill in this gap, a bone allograft surrounded by an osteogenic membrane made of a decellularized collagen matrix from human fascia lata and seeded with periosteal mesenchymal stem cells (PMSCs) was analyzed in terms of de-/recellularization, osteogenic properties, PMSC self-differentiation, and angiogenic potential. While the decellularization processes altered the ECM content differently, the main GF content was decreased in soft tissues but relatively increased in hard bone tissues. The spontaneous osteogenic differentiation was necessarily obtained through contact with a mineralized bone matrix. Trying to deepen the knowledge on the complex matrix–cell interplay could further propel these tissue engineering concepts and lead us to provide the biological elements that allow bone integration in vivo.

7 May 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
ANAmaury Namour
Amaury Namour
Marwan El MobadderMarwan El Mobadder
Marwan El Mobadder
PMPatrick Amano Matamba
Patrick Amano Matamba
LMLucia Misoaga
Lucia Misoaga
DMDelphine Magnin
Delphine Magnin
Samir NammourSamir Nammour
Samir Nammour
The fracture of nickel–titanium (Ni-Ti) instruments during root canal instrumentation leads to compromised outcomes in endodontic treatments. Despite the significant impact of instrument facture during a root canal treatment, there is still no universally accepted method to address this complication. Several previous studies have shown the ability of a Neodymium: Yttrium–Aluminum–Perovskite (Nd: YAP) laser to cut endodontic files. This study aims to determine safe irradiation conditions for a clinical procedure involving the use of a Neodymium: Yttrium–Aluminum–Perovskite (Nd: YAP) laser for removing fractured nickel–titanium files in root canals. A total of 54 extracted permanent human teeth (n = 54) were used. This study involved nine distinct groups, each employing different irradiation conditions. Groups 1 s, 3 s, 5 s, 10 s, and 15 s simply consist of irradiation for 1, 3, 5, 10, and 15 s, respectively. After identifying the longest and safest duration time, four additional groups were proposed (labeled A, B, C, and D). Group A was composed of three series of irradiations of 5 s each separated by a rest time of 30 s (L5s + 30 s RT). Group B consisted of three series of irradiations of 5 s each separated by a rest time of 60 s (L5s + 60 s RT). Group C consisted of two series of irradiations of 5 s each separated by a rest time of 30 s (L5s + 30 s RT), and group D consisted of two series of irradiations of 5 s each separated by a rest time of 5 s (L5s + 5 s RT). In all groups, during the rest time, continuous irrigation with 2.5 mL of sodium hypochlorite (3% NaOCl) was carried out. The variation in temperature during irradiation was registered with a thermocouple during irradiation with different protocols. The mean and standard deviation of the temperature increase was noted. The calculation of the temperature was made as the Δ of the highest recorded temperature at the root surface minus (−) that recorded at baseline (37°). Additionally, scanning electron microscopy (SEM) was used after irradiation in all groups in order to assess the morphological changes in the root dentinal walls. The Nd: YAP laser irradiation parameters were a power of 3W, an energy of 300 mJ per pulse, a fiber diameter of 200 µm, a pulsed mode of irradiation with a frequency of 10 Hz, a pulse duration of 150 µs, and an energy density of 955.41 J/cm2. Our results show that the safest protocol for bypassing and/or removing broken instruments involves three series of irradiation of 5 s each with a rest time of 30 s between each series. Furthermore, our results suggest that continuous irradiation for 10 s or more may be harmful for periodontal tissue.

17 January 2023 in ChemRxiv
Verified
Preprint
Open access
PDF file
FBFilippo Brienza
Filippo Brienza
KAKorneel Van Aelst
Korneel Van Aelst
FDFrançois Devred
François Devred
DMDelphine Magnin
Delphine Magnin
BSBert Sels
Bert Sels
Damien DebeckerDamien Debecker
Damien Debecker
The reductive catalytic fractionation (RCF) is an attractive method for the conversion of lignin toward valuable low-molecular weight aromatics during the pretreatment of lignocellulosic biomass. A prominent limitation to the upscaling of such technology is represented by the use of pressurized hydrogen gas. In this contribution, the role of hydrogen gas within the RCF of wheat straw biomass is investigated. The use of H2 was shown to enhance lignin depolymerization, by virtue of an improved hydrogenolysis and hydrogenation of lignin fragments, with a yield of phenolic monomers that increased from ~12 wt% of acid-insoluble lignin in the initial biomass under inert atmosphere, up to ~25 wt% under H2, for a reaction in methanol, at 250 °C, with Ru/C. The adoption of methanol, ethanol and isopropanol as hydrogen-donor solvents was also investigated in the absence of H2, and the use of ethanol was found to give the highest yield of monophenolics (up to ~20 wt%) owing to a better balance between solvolysis, hydrogenolysis, and hydrogenation of lignin. Nevertheless, a substantial loss of the carbohydrate fraction was observed for reactions performed at 250 °C, irrespective of hydrogen pressure and of the solvent employed. The use of a lower temperature of 200 °C in combination with H3PO4 resulted in an improved recovery of cellulose in the pulp and in the solubilization of hemicellulose and lignin, with the formation of monosaccharides (~14 wt% of polysaccharides in the initial biomass) and phenolic monomers (up to 18 wt%, in the absence of H2). Overall, the obtained results show that a tradeoff exists between the removal of H2 from the process and the production of low-MW phenolics during RCF, which can be improved by accurately tuning the process conditions.