Tissue engineering is a growing field. In the near future, it will probably be possible to generate a complete vital tooth from a single stem cell. Pulp revascularization is dependent on the ability of residual pulp and apical and periodontal stem cells to differentiate. These cells have the ability to generate a highly vascularized and a conjunctive rich living tissue. This one is able to colonize the available pulp space. Revascularization is a new treatment method for immature necrotic permanent teeth. Up to now, apexification procedures were applied for these teeth, using calcium dihydroxide or MTA to produce an artificial apical barrier. However, the pulp revascularization allows the stimulation of the apical development and the root maturation of immature teeth. Two pulp revascularization techniques are used in the literature, one using calcium dihydroxide and the second using a triple antibiotic paste. Based on these two different pulp revascularization protocols, which obtain the desired therapeutic success, the literature will be reviewed and analyzed according to the relevance of their choice of materials. Based on the literature, we propose a new relevant protocol and a new mixture of antibiotics.
Different approaches with different clinical outcomes have been found in treating capillary hemangioma (CH), venous lake (VL), or venous malformations (VM) of the lips. This retrospective study aims to assess scar quality, recurrence rate, and patient satisfaction after different surgeries with different laser wavelengths. A total of 143 patients with CH or VM were included. Nd:YAG laser was used for 47 patients, diode 980 nm laser was used for 32 patients (treatments by transmucosal photo-thermo-coagulation), Er,Cr:YSSG laser was used for 12 patients (treatments by excision), and CO2 laser was used for 52 patients (treatments by photo-vaporization). The Manchester scar scale was used by practitioners to assess the scar quality. The recurrence rate and patients’ satisfaction were noted at different follow-ups during 12 months. Our retrospective study showed that laser-assisted aesthetic treatment of vascular lesions (CH, VL, and VM) of the lips can be considered effective regardless of the wavelength used (Er,Cr:YSGG, CO2, Nd:YAG, and diode 980 nm) or the treatment procedure (transmucosal photo-thermo-coagulation, photo-vaporization, and surgical excision). There was no significant difference in patient and practitioner satisfaction with aesthetic outcome at 6 months follow-up. Furthermore, the treatments of lip vascular lesions performed using Er,Cr:YSGG and CO2 lasers did not show any recurrence during the 12 months of follow-up, while recurrence rates of 11% ± 1.4% and 8% ± 0.9% were seen in the diode and Nd:YAG groups, respectively.
Oral rehabilitation with dental implants has revolutionized the field of dentistry and has been proven to be an effective procedure. However, the incidence of peri-implantitis has become an emerging concern. The efficacy of the decontamination of the implant surface, by means of lasers, is still controversial. Previous studies have revealed a reduction in osteoblast adhesion to carbon-contaminated implant surfaces. This in-vitro study aimed to evaluate the decontamination of failed implants by assessing the carbon proportion, after irradiation by low-energy erbium yttrium-aluminum-garnet laser (Er:YAG) (Fotona; 2940 nm, Ljubljana, Slovenia) for a single and for multiple passages, until getting a surface, free of organic matters; to find the appropriate procedure for dental-implant surface-decontamination. Ninety implants were used. Thirty sterile implants were kept as a negative control. Thirty failed implants were irradiated by the Er:YAG laser, for a single passage, and the other thirty, for multiple passages. The parameters used in our experiments were an irradiation energy of 50 mJ, frequency of 30 Hz, and an energy density of 3.76 J/cm2. A sapphire tip, with a length of 8 mm, was used with concomitant water spray irrigation, under air 6 and water spray 4. Super short pulse mode (SSP) was of 50 μs; irradiation speed being 2 mm/s. We used energy-dispersive X-ray spectroscopy (EDX) to evaluate the carbon proportion on the surfaces of the sterile implants, the contaminated, and the lased implants, with one (LX1) and with three passages (LX3). Statistical analysis was performed by ANOVA. Results showed mean difference between the three groups (contaminated, LX1, and LX3) with p < 0.0001, as between LX1 and Group A (p < 0.0001), while the difference between LX3 and the control group was not statistically significant. The decontamination of the implant surfaces with a low-energy Er:YAG laser with three passages, appeared to be an encouraging approach.
A successful treatment of periodontitis depends largely on the successful elimination of the periodontopathogens during non-surgical and surgical mechanical debridement. In this retrospective study, data collection was conducted from 2017 to 2021. The retrospective study included 128 patients with 128 sites of localized periodontitis with pocket depths > 5 mm. The included data were based on sites that received conventional mechanical debridement followed by different adjunctive approaches. In total, 30 patients did not receive any additional treatment (SRP group), 30 patients received SRP + 980 nm diode laser irradiation only (SRP + laser), 30 patients received SRP + 3% hydrogen peroxide irrigation (SRP + H2O2) only and 30 patients received a combined treatment of 3% hydrogen peroxide and 980 nm diode laser irradiation (SRP + H2O2 + laser). Total bacterial counts (TBC) in the periodontal pocket collected for all participants before treatment, immediately after treatment, 6 weeks after treatment, 12 weeks after treatment and 6 months after treatment were statistically analyzed and compared. When the laser was used, irradiation parameters were 10 μsec/pulse duration, 10 kHz, pick power of 10 W, average power of 1 W, irradiation time of one minute with inward and outward movements, and fiber diameter of 320 μm. The irradiation was repeated 3 times/pocket. When hydrogen peroxide was used, the irrigation was conducted for one minute and repeated 3 times. The maximum reduction in TBC was obtained when SRP was coupled with 3% H2O2 irrigation followed by 980 nm diode laser irradiation. After six months of follow-up, a significant reduction in TBC was obtained for the group of SRP + H2O2 + laser when compared to all the other groups, from 7.27 × 107 before intervention to 3.21 × 107 after six months. All three approaches to SRP showed a significant reduction in TBC immediately after treatment. Values were 3.52 × 107, 4.01 × 106, 9.58 × 106, 1.98 × 106 for SRP alone, SRP + diode, SRP + H2O2 and SRP + H2O2 + diode laser, respectively. At 6 months, we saw no significant difference between SRP + laser and SRP + H2O2 with 4.01 × 107 and 4.32 × 107, respectively. This retrospective study reveals that after SRP, irrigation with 3% hydrogen peroxide and irradiation with a 980 nm diode laser within specific treatment protocol can be used as an additional approach to conventional SRP to increase the disinfection of the periodontal pockets > 5 mm.
The discomfort of patients due to dentinal hypersensitivity (DH) is one of the main challenges that dentists face in daily practice. Difficulties in DH treatment gave rise to many protocols which are currently used. The aim of this clinical study is to evaluate the effectiveness of a new protocol on the reduction of dentinal hypersensitivity with diode laser 980 nm and the application of a graphite paste. 184 patients enrolled in the study, the degree of pain was evaluated by visual analog scale (VAS), graphite paste was applied on the exposed dentine before irradiation, the application of diode laser 980 nm with continuous mode, backward motion, tangential incidence of the beam in non-contact mode and a delivery output of 1 W. Fiber’s diameter was 320 μm and total exposure time depended on the time necessary to remove the graphite paste from the teeth. Statistical analyses were performed with Prism 5® software. Pain in post-operative significantly decreased immediately after the treatment. Mean values stayed stable until a 6-month follow-up. The application is considered to be safe with long-term effectiveness.
Peri-implantitis (PI) is an inflammatory disease of peri-implant tissues, it represents the most frequent complication of dental implants. Evidence revealed that microorganisms play the chief role in causing PI. The purpose of our study is to evaluate the cleaning of contaminated dental implant surfaces by means of the Q-switch Nd:YAG (Neodymium-doped Yttrium Aluminum Garnet) laser and an increase in temperature at lased implant surfaces during the cleaning process. Seventy-eight implants (titanium grade 4) were used (Euroteknika, Sallanches, France). Thirty-six sterile implants and forty-two contaminated implants were collected from failed clinical implants for different reasons, independent from the study. Thirty-six contaminated implants were partially irradiated by Q-switch Nd:YAG laser (1064 nm). Six other contaminated implants were used for temperature rise evaluation. All laser irradiations were calibrated by means of a powermetter in order to evaluate the effective delivered energy. The irradiation conditions delivered per pulse on the target were effectively: energy density per pulse of 0.597 J/cm2, pick powers density of 56 mW/cm2, 270 mW per pulse with a spot diameter of 2.4 mm, and with repetition rate of 10 Hz for pulse duration of 6 ns. Irradiation was performed during a total time of 2 s in a non-contact mode at a distance of 0.5 mm from implant surfaces. The parameters were chosen according to the results of a theoretical modeling calculation of the Nd:YAG laser fluency on implant surface. Evaluation of contaminants removal showed that the cleaning of the irradiated implant surfaces was statistically similar to those of sterile implants (p-value ≤ 0.05). SEM analysis confirmed that our parameters did not alter the lased surfaces. The increase in temperature generated at lased implant surfaces during cleaning was below 1 °C. According to our findings, Q-switch Nd:YAG laser with short pulse duration in nanoseconds is able to significantly clean contaminated implant surfaces. Irradiation parameters used in our study can be considered safe for periodontal tissue.