Evert-jan Vonken

Dr. Evert-jan Vonken

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Open access
JHJoost A. van Herwaarden van Herwaarden
Joost A. van Herwaarden van Herwaarden
MJMarloes M. Jansen
Marloes M. Jansen
EVEvert-jan Vonken
Evert-jan Vonken
TBTrijntje Bloemert-Tuin
Trijntje Bloemert-Tuin
RBRoland W.M. Bullens
Roland W.M. Bullens
CHConstantijn E.V.B. Hazenberg
Constantijn E.V.B. Hazenberg
Endovascular procedures are conventionally conducted using two dimensional fluoroscopy. A new technology platform, Fiber Optic RealShape (FORS), has recently been introduced allowing real time, three dimensional visualisation of endovascular devices using fiberoptic technology. It functions as an add on to conventional fluoroscopy and may facilitate endovascular procedures. This first in human study assessed the feasibility of FORS in clinical practice. A prospective cohort feasibility study was performed between July and December 2018. Patients undergoing (regular or complex) endovascular aortic repair (EVAR) or endovascular peripheral lesion repair (EVPLR) were recruited. FORS guidance was used exclusively during navigational tasks such as target vessel catheterisation or crossing of stenotic lesions. Three types of FORS enabled devices were available: a flexible guidewire, a Cobra-2 catheter, and a Berenstein catheter. Devices were chosen at the physician's discretion and could comprise any combination of FORS and non-FORS devices. The primary study endpoint was technical success of the navigational tasks using FORS enabled devices. Secondary study endpoints were user experience and fluoroscopy time. The study enrolled 22 patients: 14 EVAR and eight EVPLR patients. Owing to a technical issue during start up, the FORS system could not be used in one EVAR. The remaining 21 procedures proceeded without device or technology related complications and involved 66 navigational tasks. In 60 tasks (90.9%), technical success was achieved using at least one FORS enabled device. Users rated FORS based image guidance "better than standard guidance" in 16 of 21 and "equal to standard guidance" in five of 21 procedures. Fluoroscopy time ranged from 0.0 to 52.2 min. Several tasks were completed without or with only minimal X-ray use. Real time navigation using FORS technology is safe and feasible in abdominal and peripheral endovascular procedures. FORS has the potential to improve intra-operative image guidance. Comparative studies are needed to assess these benefits and potential radiation reduction.

4 August 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JWJoep Wijnand
Joep Wijnand
DZDevin Zarkowsky
Devin Zarkowsky
BWBian Wu
Bian Wu
SHSteven T. W. van Haelst
Steven T. W. van Haelst
EVEvert-jan Vonken
Evert-jan Vonken
MCMichael S. Conte
Michael S. Conte
Objective: The 2020 Global Vascular Guidelines aim at improving decision making in Chronic Limb-Threatening Ischemia (CLTI) by providing a framework for evidence-based revascularization. Herein, the Global Limb Anatomic Staging System (GLASS) serves to estimate the chance of success and patency of arterial pathway revascularization based on the extent and distribution of the atherosclerotic lesions. We report the preliminary feasibility results and observer variability of the GLASS. GLASS is a part of the new global guideline and posed as a promising additional tool for EBR strategies to predict the success of lower extremity arterial revascularization. This study reports on the consistency of GLASS scoring to maximize inter-observer agreement and facilitate its application. Methods: GLASS separately scores the femoropopliteal (FP) and infrapopliteal (IP) segment based on stenosis severity, lesion length and the extent of calcification within the target artery pathway (TAP). In our stepwise approach, we used two angiographic datasets. Each following step was based on the lessons learned from the previous step. The primary outcome was inter-observer agreement measured as Cohen’s Kappa, scored by two (step 1 + 2) and four (step 3) blinded and experienced observers, respectively. Steps 1 (n = 139) and 2 (n = 50) were executed within a dataset of a Dutch interventional RCT in CLTI. Step 3 (n = 100) was performed in randomly selected all-comer CLTI patients from two vascular centers in the United States. Results: In step 1, kappa values were 0.346 (FP) and 0.180 (IP). In step 2, applied in the same dataset, the use of other experienced observers and a provided TAP, resulted in similar low kappa values 0.406 (FP) and 0.089 (IP). Subsequently, in step 3, the formation of an altered stepwise approach using component scoring, such as separate scoring of calcification and adding a ruler to the images resulted in kappa values increasing to 0.796 (FP) and 0.730 (IP). Conclusion: This retrospective GLASS validation study revealed low inter-observer agreement for unconditioned scoring. A stepwise component scoring provides acceptable agreement and a solid base for further prospective validation studies to investigate how GLASS relates to treatment outcomes.

1 July 2020 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
MJMarloes Jansen
Marloes Jansen
AKAnuradha Khandige
Anuradha Khandige
HKHicham Kobeiter
Hicham Kobeiter
EVEvert-jan Vonken
Evert-jan Vonken
CHConstantijn Hazenberg
Constantijn Hazenberg
JHJoost van Herwaarden
Joost van Herwaarden

13 September 2022 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
JKJordi P. D. Kleinloog
Jordi P. D. Kleinloog
SMStefano Mandija
Stefano Mandija
Federico D'AgataFederico D'Agata
Federico D'Agata
HLHongyan Liu
Hongyan Liu
OHOscar van der Heide
Oscar van der Heide
ASAlessandro Sbrizzi
Alessandro Sbrizzi
Background: Magnetic Resonance Spin TomogrAphy in Time‐domain (MR‐STAT) can reconstruct whole‐brain multi‐parametric quantitative maps (eg, T1, T2) from a 5‐minute MR acquisition. These quantitative maps can be leveraged for synthetization of clinical image contrasts.Purpose: The objective was to assess image quality and overall diagnostic accuracy of synthetic MR‐STAT contrasts compared to conventional contrast‐weighted images.Study Type: Prospective cross‐sectional clinical trial.Population: Fifty participants with a median age of 45 years (range: 21–79 years) consisting of 10 healthy participants and 40 patients with neurological diseases (brain tumor, epilepsy, multiple sclerosis or stroke).Field Strength/Sequence: 3T/Conventional contrast‐weighted imaging (T1/T2 weighted, proton density [PD] weighted, and fluid‐attenuated inversion recovery [FLAIR]) and a MR‐STAT acquisition (2D Cartesian spoiled gradient echo with varying flip angle preceded by a non‐selective inversion pulse).Assessment: Quantitative T1, T2, and PD maps were computed from the MR‐STAT acquisition, from which synthetic contrasts were generated. Three neuroradiologists blinded for image type and disease randomly and independently evaluated synthetic and conventional datasets for image quality and diagnostic accuracy, which was assessed by comparison with the clinically confirmed diagnosis.Statistical Tests: Image quality and consequent acceptability for diagnostic use was assessed with a McNemar's test (one‐sided α = 0.025). Wilcoxon signed rank test with a one‐sided α = 0.025 and a margin of Δ = 0.5 on the 5‐level Likert scale was used to assess non‐inferiority.Results: All data sets were similar in acceptability for diagnostic use (≥3 Likert‐scale) between techniques (T1w:P = 0.105, PDw:P = 1.000, FLAIR:P = 0.564). However, only the synthetic MR‐STAT T2 weighted images were significantly non‐inferior to their conventional counterpart; all other synthetic datasets were inferior (T1w:P = 0.260, PDw:P = 1.000, FLAIR:P = 1.000). Moreover, true positive/negative rates were similar between techniques (conventional: 88%, MR‐STAT: 84%).Data Conclusion: MR‐STAT is a quantitative technique that may provide radiologists with clinically useful synthetic contrast images within substantially reduced scan time.Evidence Level: 1Technical Efficacy: Stage 2

30 December 2015 in Journal of Therapeutic Ultrasound
Verified
Journal Article
Open access
PDF file
JBJohanna M. M. van Breugel
Johanna M. M. van Breugel
RNRobbert J. Nijenhuis
Robbert J. Nijenhuis
MRMario G. Ries
Mario G. Ries
RTRaechel J. Toorop
Raechel J. Toorop
EVEvert-jan Vonken
Evert-jan Vonken
MBMaurice A. A. J. van Den Bosch
Maurice A. A. J. van Den Bosch
Therapy of choice for symptomatic vascular malformations consists of surgery, sclerotherapy, or embolization. However, these techniques are invasive with possible complications and require hospitalization. We present a novel non-invasive technique, i.e., magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation, for the treatment of a vascular malformation in a patient. This technique applies high-intensity sound waves transcutaneously to the body and is fully non-invasive. MRI guidance is the novel aspect of HIFU treatments and is used for exquisite delineation and localization of the lesion and accurate real-time temperature monitoring during tissue ablation. MR-HIFU is a well-established treatment option for uterine fibroids and is currently being investigated for, e.g., bone tumors, breast cancer, prostate cancer, and liver cancer. MR-HIFU of vascular malformations has not been a topic of research yet. Volumetric MR-HIFU ablation of a vascular malformation in the lower extremity of an 18-year-old male patient was performed. Temperatures of 62–80 °C were reached in the target lesion with sonications of 4 × 4 × 8 mm using powers of 200 W for 30 % of the tumor volume. After 13 months, pain score was reduced to <2 after extreme exertion for several hours and to 0 for daily activities. Radiofrequency ablation and cryoablation are minimally invasive techniques that have been tried on low-flow vascular malformations with inconsistent results. Furthermore, both techniques require probe insertion, which is associated with risks of wound infection and hospitalization. Since MR-HIFU is truly non-invasive, these risks are negligible. In conclusion, we reported a successful non-invasive treatment of a vascular malformation with MR-HIFU in a clinical patient including long-term follow-up data for the first time. The patient reported qualitatively sustained pain reduction up to 13 months post treatment.

14 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PDPieter Thomas Deckers
Pieter Thomas Deckers
AKAnnick Kronenburg
Annick Kronenburg
EBEsther van Den Berg
Esther van Den Berg
MSMonique M. van Schooneveld
Monique M. van Schooneveld
EVEvert-jan Vonken
Evert-jan Vonken
KBKees P. J. Braun
Kees P. J. Braun
Background: It remains unclear whether revascularization of moyamoya vasculopathy (MMV) has a positive effect on cognitive function. In this prospective, single-center study, we investigated the effect of revascularization on cognitive function in patients with MMV. We report clinical and radiological outcome parameters and the associations between clinical determinants and change in neurocognitive functioning. Methods: We consecutively included all MMV patients at a Dutch tertiary referral hospital who underwent pre- and postoperative standardized neuropsychological evaluation, [15O]H2O-PET (including cerebrovascular reactivity (CVR)), MRI, cerebral angiography, and completed standardized questionnaires on clinical outcome and quality of life (QOL). To explore the association between patient characteristics, imaging findings, and change in the z-scores of the cognitive domains, we used multivariable linear- and Bayesian regression analysis. Results: We included 40 patients of whom 35 (27 females, 21 children) were treated surgically. One patient died after surgery, and two withdrew from the study. TIA- and headache frequency and modified Rankin scale (mRS) improved (resp. p = 0.001, 0.019, 0.039). Eleven patients (seven children) developed a new infarct during follow-up (31%), five of which were symptomatic. CVR-scores improved significantly (p < 0.0005). The language domain improved (p = 0.029); other domains remained stable. In adults, there was an improvement in QOL. We could not find an association between change in imaging and cognitive scores. Conclusion: In this cohort of Western MMV patients, TIA frequency, headache, CVR, and mRS improved significantly after revascularization. The language domain significantly improved, while others remained stable. We could not find an association between changes in CVR and cognitive scores.