1 February 2018 in Magnetic Resonance Imaging
29 November 2011 in Magnetic Resonance in Medicine
Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limits. Computing the SAR over a three‐dimensional domain can require several minutes and implementing this computation in a radiofrequency pulse design algorithm could slow down prohibitively the numerical process. In this article, a fast optimization algorithm is designed acting on a limited number of control points, which are strategically selected locations from the entire domain. The selection is performed by comparing the largest eigenvalues and the corresponding eigenvectors of the matrices which locally describe the tissue's amount of heating. The computation complexity is dramatically reduced. An additional critical step to accelerate the computations is to apply a multi shift conjugate gradient algorithm. Two transmit array setups are studied: a two channel 3 T birdcage body coil and a 12‐channel 7 T transverse electromagnetic (TEM) head coil. In comparison with minimum power radiofrequency pulses, it is shown that a reduction of 36.5% and 35%, respectively, in the local NgSAR can be achieved within short, clinically feasible, computation times. Magn Reson Med, 2012.
14 September 2021 in IEEE Transactions on Medical Imaging
The MR-Linac is a combination of an MR-scanner and radiotherapy linear accelerator (Linac) which holds the promise to increase the precision of radiotherapy treatments with MR-guided radiotherapy by monitoring motion during radiotherapy with MRI, and adjusting the radiotherapy plan accordingly. Optimal MR-guidance for respiratory motion during radiotherapy requires MR-based 3D motion estimation with a latency of 200–500 ms. Currently this is still challenging since typical methods rely on MR-images, and are therefore limited by the 3D MR-imaging latency. In this work, we present a method to perform non-rigid 3D respiratory motion estimation with 170 ms latency, including both acquisition and reconstruction. The proposed method called real-time low-rank MR-MOTUS reconstructs motion-fields directly from ${k}$ -space data, and leverages an explicit low-rank decomposition of motion-fields to split the large scale 3D+t motion-field reconstruction problem posed in our previous work into two parts: (I) a medium-scale offline preparation phase and (II) a small-scale online inference phase which exploits the results of the offline phase for real-time computations. The method was validated on free-breathing data of five volunteers, acquired with a 1.5T Elekta Unity MR-Linac. Results show that the reconstructed 3D motion-field are anatomically plausible, highly correlated with a self-navigation motion surrogate ( ${R}={0.975} \pm {0.0110}$ ), and can be reconstructed with a total latency of 170 ms that is sufficient for real-time MR-guided abdominal radiotherapy.
10 November 2020 in Magnetic Resonance in Medicine
Purpose: With the recent introduction of the MR‐LINAC, an MR‐scanner combined with a radiotherapy LINAC, MR‐based motion estimation has become of increasing interest to (retrospectively) characterize tumor and organs‐at‐risk motion during radiotherapy. To this extent, we introduce low‐rank MR‐MOTUS, a framework to retrospectively reconstruct time‐resolved nonrigid 3D+t motion fields from a single low‐resolution reference image and prospectively undersampled k‐space data acquired during motion.Theory: Low‐rank MR‐MOTUS exploits spatiotemporal correlations in internal body motion with a low‐rank motion model, and inverts a signal model that relates motion fields directly to a reference image and k‐space data. The low‐rank model reduces the degrees‐of‐freedom, memory consumption, and reconstruction times by assuming a factorization of space‐time motion fields in spatial and temporal components.Methods: Low‐rank MR‐MOTUS was employed to estimate motion in 2D/3D abdominothoracic scans and 3D head scans. Data were acquired using golden‐ratio radial readouts. Reconstructed 2D and 3D respiratory motion fields were, respectively, validated against time‐resolved and respiratory‐resolved image reconstructions, and the head motion against static image reconstructions from fully sampled data acquired right before and right after the motion.Results: Results show that 2D+t respiratory motion can be estimated retrospectively at 40.8 motion fields per second, 3D+t respiratory motion at 7.6 motion fields per second and 3D+t head‐neck motion at 9.3 motion fields per second. The validations show good consistency with image reconstructions.Conclusions: The proposed framework can estimate time‐resolved nonrigid 3D motion fields, which allows to characterize drifts and intra and inter‐cycle patterns in breathing motion during radiotherapy, and could form the basis for real‐time MR‐guided radiotherapy.
22 January 2016 in Magnetic Resonance in Medicine
Purpose: The design of turbo spin‐echo sequences is modeled as a dynamic optimization problem which includes the case of inhomogeneous transmit radiofrequency fields. This problem is efficiently solved by optimal control techniques making it possible to design patient‐specific sequences online.Theory and Methods: The extended phase graph formalism is employed to model the signal evolution. The design problem is cast as an optimal control problem and an efficient numerical procedure for its solution is given. The numerical and experimental tests address standard multiecho sequences and pTx configurations.Results: Standard, analytically derived flip angle trains are recovered by the numerical optimal control approach. New sequences are designed where constraints on radiofrequency total and peak power are included. In the case of parallel transmit application, the method is able to calculate the optimal echo train for two‐dimensional and three‐dimensional turbo spin echo sequences in the order of 10 s with a single central processing unit (CPU) implementation. The image contrast is maintained through the whole field of view despite inhomogeneities of the radiofrequency fields.Conclusion: The optimal control design sheds new light on the sequence design process and makes it possible to design sequences in an online, patient‐specific fashion. Magn Reson Med 77:361–373, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine
5 May 2011 in Magnetic Resonance in Medicine
Designing multi dimensional ratio frequency excitation pulses in the small flip angle regime commonly reduces to the solution of a least squares problem, which requires regularization to be solved numerically. Usually, regularization is carried out by the introduction of a penalty, λ, on the solution norm. In most cases, the optimal regularization parameter is not known a priori and the problem needs to be solved for several values of λ. The optimal value can be selected, typically by plotting the L‐curve. In this article, a conjugate gradients‐based algorithm is applied to design ratio frequency pulses in a time‐efficient way without a priori knowledge of the optimal regularization parameter. The computation time is reduced considerably (by a factor 10 in a typical set up) with respect to the standard conjugate gradients for least square since just one run of the algorithm is required. Simulations are shown and the performance is compared to that of conjugate gradients for least square. Magn Reson Med, 2011.