Hugo W. A. M. De Jong

Dr. Hugo W. A. M. De Jong


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2007 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
HJHugo W. A. M. De Jong
Hugo W. A. M. De Jong
FVFloris H P van Velden
Floris H P van Velden
RKReina W Kloet
Reina W Kloet
FBFred L Buijs
Fred L Buijs
RBRonald Boellaard
Ronald Boellaard
Adriaan Anthonius LammertsmaAdriaan Anthonius Lammertsma
Adriaan Anthonius Lammertsma
The ECAT high resolution research tomograph (HRRT) is a dedicated brain and small animal PET scanner, with design features that enable high image spatial resolution combined with high sensitivity. The HRRT is the first commercially available scanner that utilizes a double layer of LSO/LYSO crystals to achieve photon detection with depth-of-interaction information. In this study, the performance of the commercial LSO/LYSO HRRT was characterized, using the NEMA protocol as a guideline. Besides measurement of spatial resolution, energy resolution, sensitivity, scatter fraction, count rate performance, correction for attenuation and scatter, hot spot recovery and image quality, a clinical evaluation was performed by means of a HR+/HRRT human brain comparison study. Point source resolution varied across the field of view from approximately 2.3 to 3.2 mm (FWHM) in the transaxial direction and from 2.5 to 3.4 mm in the axial direction. Absolute line-source sensitivity ranged from 2.5 to 3.3% and the NEMA-2001 scatter fraction equalled 45%. Maximum NECR was 45 kcps and 148 kcps according to the NEMA-2001 and 1994 protocols, respectively. Attenuation and scatter correction led to a volume uniformity of 6.3% and a system uniformity of 3.1%. Reconstructed values deviated up to 15 and 8% in regions with high and low densities, respectively, which can possibly be assigned to inaccuracies in scatter estimation. Hot spot recovery ranged from 60 to 94% for spheres with diameters of 1 to 2.2 cm. A high quantitative agreement was met between HR+ and HRRT clinical data. In conclusion, the ECAT HRRT has excellent resolution and sensitivity properties, which is a crucial advantage in many research studies.

13 May 2014 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
MEMattijs Elschot
Mattijs Elschot
JNJohannes F. W. Nijsen
Johannes F. W. Nijsen
MLMarnix G. E. H. Lam
Marnix G. E. H. Lam
MSMaarten L. J. Smits
Maarten L. J. Smits
JPJip F. Prince
Jip F. Prince
HJHugo W. A. M. De Jong
Hugo W. A. M. De Jong

2 November 2018 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
RBRemco Bastiaannet
Remco Bastiaannet
SKS. Cheenu Kappadath
S. Cheenu Kappadath
BKBritt Kunnen
Britt Kunnen
ABArthur Johannes Anthonius Theodorus Braat
Arthur Johannes Anthonius Theodorus Braat
MLMarnix G.E.H. Lam Lam
Marnix G.E.H. Lam Lam
HJHugo W. A. M. De Jong
Hugo W. A. M. De Jong
Radioembolization is an established treatment for chemoresistant and unresectable liver cancers. Currently, treatment planning is often based on semi-empirical methods, which yield acceptable toxicity profiles and have enabled the large-scale application in a palliative setting. However, recently, five large randomized controlled trials using resin microspheres failed to demonstrate a significant improvement in either progression-free survival or overall survival in both hepatocellular carcinoma and metastatic colorectal cancer. One reason for this might be that the activity prescription methods used in these studies are suboptimal for many patients. In this review, the current dosimetric methods and their caveats are evaluated. Furthermore, the current state-of-the-art of image-guided dosimetry and advanced radiobiological modeling is reviewed from a physics’ perspective. The current literature is explored for the observation of robust dose-response relationships followed by an overview of recent advancements in quantitative image reconstruction in relation to image-guided dosimetry. This review is concluded with a discussion on areas where further research is necessary in order to arrive at a personalized treatment method that provides optimal tumor control and is clinically feasible.

15 June 2010 in Journal of Experimental & Clinical Cancer Research
Verified
Journal Article
Open access
PDF file
MSMaarten L.J. Smits
Maarten L.J. Smits
JNJohannes Fw Nijsen
Johannes Fw Nijsen
MBMaurice Aaj van Den Bosch
Maurice Aaj van Den Bosch
MLMarnix G.E.H. Lam Lam
Marnix G.E.H. Lam Lam
MVMaarten Ad Vente
Maarten Ad Vente
BZBernard A Zonnenberg
Bernard A Zonnenberg
Background: Intra-arterial radioembolization with yttrium-90 microspheres ( 90Y-RE) is an increasingly used therapy for patients with unresectable liver malignancies. Over the last decade, radioactive holmium-166 poly(L-lactic acid) microspheres ( 166Ho-PLLA-MS) have been developed as a possible alternative to 90Y-RE. Next to high-energy beta-radiation, 166Ho also emits gamma-radiation, which allows for imaging by gamma scintigraphy. In addition, Ho is a highly paramagnetic element and can therefore be visualized by MRI. These imaging modalities are useful for assessment of the biodistribution, and allow dosimetry through quantitative analysis of the scintigraphic and MR images. Previous studies have demonstrated the safety of 166Ho-PLLA-MS radioembolization ( 166Ho-RE) in animals. The aim of this phase I trial is to assess the safety and toxicity profile of 166Ho-RE in patients with liver metastases. Methods: The HEPAR study (Holmium Embolization Particles for Arterial Radiotherapy) is a non-randomized, open label, safety study. We aim to include 15 to 24 patients with liver metastases of any origin, who have chemotherapy-refractory disease and who are not amenable to surgical resection. Prior to treatment, in addition to the standard technetium-99m labelled macroaggregated albumin ( 99mTc-MAA) dose, a low radioactive safety dose of 60-mg 166Ho-PLLA-MS will be administered. Patients are treated in 4 cohorts of 3-6 patients, according to a standard dose escalation protocol (20 Gy, 40 Gy, 60 Gy, and 80 Gy, respectively). The primary objective will be to establish the maximum tolerated radiation dose of 166Ho-PLLA-MS. Secondary objectives are to assess tumour response, biodistribution, performance status, quality of life, and to compare the 166Ho-PLLA-MS safety dose and the 99mTc-MAA dose distributions with respect to the ability to accurately predict microsphere distribution. Discussion: This will be the first clinical study on 166Ho-RE. Based on preclinical studies, it is expected that 166Ho-RE has a safety and toxicity profile comparable to that of 90Y-RE. The biochemical and radionuclide characteristics of 166Ho-PLLA-MS that enable accurate dosimetry calculations and biodistribution assessment may however improve the overall safety of the procedure. Trial registration: ClinicalTrials.gov NCT01031784

21 June 2022 in CardioVascular and Interventional Radiology
Verified
Journal Article
Open access
PDF file
MSMartina Stella
Martina Stella
ABArthur Johannes Anthonius Theodorus Braat
Arthur Johannes Anthonius Theodorus Braat
RRRob van Rooij
Rob van Rooij
HJHugo W. A. M. De Jong
Hugo W. A. M. De Jong
MLMarnix G.E.H. Lam Lam
Marnix G.E.H. Lam Lam
Since its first suggestion as possible option for liver radioembolization treatment, the therapeutic isotope holmium-166 (166Ho) caught the experts’ attention due to its imaging possibilities. Being not only a beta, but also a gamma emitter and a lanthanide, 166Ho can be imaged using single-photon emission computed tomography and magnetic resonance imaging, respectively. Another advantage of 166Ho is the possibility to perform the scout and treatment procedure with the same particle. This prospect paves the way to an individualized treatment procedure, gaining more control over dosimetry-based patient selection and treatment planning. In this review, an overview on 166Ho liver radioembolization will be presented. The current clinical workflow, together with the most relevant clinical findings and the future prospective will be provided.

22 June 2018 in Cerebrovascular Diseases
Verified
Journal Article
Open access
PDF file
FKFrans Kauw
Frans Kauw
RTRichard A.P. Takx
Richard A.P. Takx
HJHugo W. A. M. De Jong
Hugo W. A. M. De Jong
BVBirgitta K. Velthuis
Birgitta K. Velthuis
LKL. Jaap Kappelle
L. Jaap Kappelle
JDJan Willem Dankbaar
Jan Willem Dankbaar
Background: Predictors of recurrent ischemic stroke are less well known in patients with a recent ischemic stroke than in patients with transient ischemic attack (TIA). We identified clinical and radiological factors for predicting recurrent ischemic stroke in patients with recent ischemic stroke. Methods: A systematic search in PubMed, Embase, Cochrane Library, and CINAHL was performed with the terms “ischemic stroke,” “predictors/determinants,” and “recurrence.” Quality assessment of the articles was performed and the level of evidence was graded for the articles included for the meta-analysis. Pooled risk ratios (RR) and heterogeneity (I2) were calculated using inverse variance random effects models. Results: Ten articles with high-quality results were identified for meta-analysis. Past medical history of stroke or TIA was a predictor of recurrent ischemic stroke (pooled RR 2.5, 95% CI 2.1–3.1). Small vessel strokes were associated with a lower risk of recurrence than large vessel strokes (pooled RR 0.3, 95% CI 0.1–0.7). Patients with stroke of an undetermined cause had a lower risk of recurrence than patients with large artery atherosclerosis (pooled RR 0.5, 95% CI 0.2–1.1). We found no studies using CT or ultrasound for the prediction of recurrent ischemic stroke. The following MRI findings were predictors of recurrent ischemic stroke: multiple lesions (pooled RR 1.7, 95% CI 1.5–2.0), multiple stage lesions (pooled RR 4.1, 95% CI 3.1–5.5), multiple territory lesions (pooled RR 2.9, 95% CI 2.0–4.2), chronic infarcts (pooled RR 1.5, 95% CI 1.2–1.9), and isolated cortical lesions (pooled RR 2.2, 95% CI 1.5–3.2). Conclusions: In patients with a recent ischemic stroke, a history of stroke or TIA and the subtype large artery atherosclerosis are associated with an increased risk of recurrent ischemic stroke. Predictors evaluated with MRI include multiple ischemic changes and isolated cortical lesions. Predictors of recurrent ischemic stroke concerning CT or ultrasound have not been published.