Rob van Rooij

Dr. Rob van Rooij

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2011 in Science
Verified
Journal Article
Closed access
PDF file
RRRob van Rooij
Rob van Rooij
JBJ. S. Borbely
J. S. Borbely
JSJ. Simonet
J. Simonet
MHM. D. Hoogerland
M. D. Hoogerland
KEK. S. E. Eikema
K. S. E. Eikema
WVW. Vassen
W. Vassen
Precision spectroscopy of simple atomic systems has refined our understanding of the fundamental laws of quantum physics. In particular, helium spectroscopy has played a crucial role in describing two-electron interactions, determining the fine-structure constant and extracting the size of the helium nucleus. Here we present a measurement of the doubly forbidden 1557-nanometer transition connecting the two metastable states of helium (the lowest energy triplet state 2 3S1 and first excited singlet state 2 1S0), for which quantum electrodynamic and nuclear size effects are very strong. This transition is weaker by 14 orders of magnitude than the most predominantly measured transition in helium. Ultracold, submicrokelvin, fermionic 3He and bosonic 4He atoms are used to obtain a precision of 8 × 10−12, providing a stringent test of two-electron quantum electrodynamic theory and of nuclear few-body theory.

21 June 2022 in CardioVascular and Interventional Radiology
Verified
Journal Article
Open access
PDF file
MSMartina Stella
Martina Stella
ABArthur Johannes Anthonius Theodorus Braat
Arthur Johannes Anthonius Theodorus Braat
RRRob van Rooij
Rob van Rooij
HJHugo W. A. M. De Jong
Hugo W. A. M. De Jong
MLMarnix G.E.H. Lam Lam
Marnix G.E.H. Lam Lam
Since its first suggestion as possible option for liver radioembolization treatment, the therapeutic isotope holmium-166 (166Ho) caught the experts’ attention due to its imaging possibilities. Being not only a beta, but also a gamma emitter and a lanthanide, 166Ho can be imaged using single-photon emission computed tomography and magnetic resonance imaging, respectively. Another advantage of 166Ho is the possibility to perform the scout and treatment procedure with the same particle. This prospect paves the way to an individualized treatment procedure, gaining more control over dosimetry-based patient selection and treatment planning. In this review, an overview on 166Ho liver radioembolization will be presented. The current clinical workflow, together with the most relevant clinical findings and the future prospective will be provided.

25 August 2020 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
ITInne J. Den Toom
Inne J. Den Toom
RMRutger Mahieu
Rutger Mahieu
RRRob van Rooij
Rob van Rooij
RERobert J. J. van Es
Robert J. J. van Es
MHMonique G. G. Hobbelink
Monique G. G. Hobbelink
Remco De BreeRemco De Bree
Remco De Bree
Purpose: Sentinel lymph node (SLN) biopsy has proven to reliably stage the clinically negative neck in early-stage oral squamous cell carcinoma (OSCC). [99mTc]Tc-tilmanocept may be of benefit in OSCC with complex lymphatic drainage patterns and close spatial relation to SLNs. Methods: A prospective within-patient evaluation study was designed to compare [99mTc]Tc-tilmanocept with [99mTc]Tc-nanocolloid for SLN detection. A total of 20 patients with early-stage OSCC were included, who underwent lymphoscintigraphy with both tracers. Both lymphoscintigraphic images of each patient were evaluated for SLN detection and radiotracer distribution at 2–4 h post-injection. Results: The injection site’s remaining radioactivity was significantly lower for [99mTc]Tc-tilmanocept (29.9%), compared with [99mTc]Tc-nanocolloid (60.9%; p < 0.001). Radioactive uptake in SLNs was significantly lower for [99mTc]Tc-tilmanocept (1.95%) compared with [99mTc]Tc-nanocolloid (3.16%; p = 0.010). No significant difference was seen in SLN to injection site ratio in radioactivity between [99mTc]Tc-tilmanocept (0.066) and [99mTc]Tc-nanocolloid (0.054; p = 0.232). A median of 3.0 and 2.5 SLNs were identified with [99mTc]Tc-tilmanocept and [99mTc]Tc-nanocolloid, respectively (p = 0.297). Radioactive uptake in higher echelon nodes was not significantly different between [99mTc]Tc-tilmanocept (0.57%) and [99mTc]Tc-nanocolloid (0.86%) (p = 0.052). A median of 2.0 and 2.5 higher echelon nodes was identified with [99mTc]Tc-tilmanocept and [99mTc]Tc-nanocolloid, respectively (p = 0.083). Conclusion: [99mTc]Tc-tilmanocept had a higher injection site clearance, but at the same time a lower uptake in the SLN, resulting in an SLN to injection site ratio, which was not significantly different from [99mTc]Tc-nanocolloid. The relatively low-radioactive uptake in SLNs of [99mTc]Tc-tilmanocept may limit intraoperative detection of SLNs, but can be overcome by a higher injection dose.

30 April 2015 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
JPJip F. Prince
Jip F. Prince
RRRob van Rooij
Rob van Rooij
GBGijsbert H. Bol
Gijsbert H. Bol
HJHugo W.A.M. de Jong
Hugo W.A.M. de Jong
MBMaurice A.A.J. van Den Bosch
Maurice A.A.J. van Den Bosch
MLMarnix G.E.H. Lam
Marnix G.E.H. Lam
Before 166Ho radioembolization, a small batch of the same type of microspheres is administered as a scout dose instead of the conventional 99mTc-macroaggregated albumin (99mTc-MAA). The 166Ho scout dose provides a more accurate and precise lung shunt assessment. However, in contrast to 99mTc-MAA, an unintended extrahepatic deposition of this β-emitting scout dose could inflict radiation damage, the extent of which we aimed to quantify in this study. Methods: All patients eligible for radioembolization in our institute between January 2011 and March 2014 were reviewed. Of the extrahepatic depositions of 99mTc-MAA on SPECT, the amount and volume were measured. These were used to calculate the theoretic absorbed dose in the case a 166Ho scout dose had been used. The extrahepatic activity was measured as the sum of all voxels of the deposition. Volumes were measured using a threshold technique including all voxels from the maximum voxel intensity up to a certain percentage. The threshold needed to obtain the true volume was studied in a phantom study. Results: In the phantom study, a threshold of 40% was found to overestimate the volume, with the consequence of underestimating the absorbed dose. Of 160 patients, 32 patients (34 cases) of extrahepatic deposition were identified. The depositions contained a median of 1.3% (range, 0.1%–19.5%) of the administered activity in a median volume of 6.8 mL (range, 1.1–42 mL). The use of a scout dose of 250 MBq of 166Ho microspheres in these cases would theoretically have resulted in a median absorbed dose of 6.0 Gy (range, 0.9–374 Gy). The dose exceeded a limit of 49 Gy (reported in 2013) in 2 of 34 cases (5.9%; 95% confidence interval, 0.7%–20.1%) or 2 of 160 (1.3%; 95% confidence interval, 0.1%–4.7%) of all patients. In these 2 patients with a large absorbed dose (112 and 374 Gy), the culprit vessel was identified in 1 case. Conclusion: Extrahepatic deposition of a 166Ho scout dose seems to be theoretically safe in most patients. Its safety in clinical practice is being evaluated in ongoing clinical trials.

12 November 2021 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
MSMartina Stella
Martina Stella
RRRob van Rooij
Rob van Rooij
MLMarnix G.E.H. Lam Lam
Marnix G.E.H. Lam Lam
HJHugo W. A. M. De Jong
Hugo W. A. M. De Jong
ABArthur Johannes Anthonius Theodorus Braat
Arthur Johannes Anthonius Theodorus Braat
Radiation pneumonitis is a rare but possibly fatal side effect of Yttrium-90 (90Y) radioembolization. It may occur 1 to 6 months after therapy, in case a significant part of the 90Y microspheres shunt to the lungs. In current clinical practice, a predicted value of lung dose greater than 30Gy is considered a criterion to exclude patients from treatment. However, contrasting findings regarding the occurrence of radiation pneumonitis and lung dose were previously reported in literature. In this study, the relationship between the lung dose value and the eventual occurrence of radiation pneumonitis after 90Y radioembolization was investigated. Methods: A total of 317 90Y liver radioembolization procedures performed during an 8-years period (Feb.2012–Sep.2020) were retrospectively analyzed. Predicted lung mean dose using 99mTc-MAA planar scintigraphy (LMDMAA) acquired during the planning phase and left lung mean dose (LMDY-90) using the 90Y PET/CT acquired after the treatment were calculated. For the lung dose computation, it was chosen to use the left lung as representative lung volume, to compensate for the scatter from the liver moving in the cranial-caudal direction due to breathing and mainly affecting the right lung. Results: Two hundred and seventy-two patients underwent 90Y procedures, of which 63% performed with glass microspheres and 37% with resin microspheres. Median injected activity was 1974MBq (range: 242-9538MBq). Median LMDMAA was 3.5Gy (range: 0.2–89.0Gy). For 14 procedures LMDMAA was >30Gy. Median LMDY-90 was 1Gy (range: 0.0–22.1Gy). No patients had a LMDY-90 >30Gy. Of the three patients with a LMDY-90 >12Gy, two patients (LMDY-90 = 22.1Gy, LMDMAA = 89Gy and LMDY-90 = 17.7Gy, LMDMAA = 34.1Gy, respectively) developed radiation pneumonitis and consequently died. A third patient with a LMDY-90 equal to 18.4Gy (LMDMAA = 29.1Gy) died 2 months after treatment, before imaging evaluation, due to progressive disease. Conclusion: The occurrence of radiation pneumonitis as a consequence of lung shunt following 90Y radioembolization is rare (<1 %). No radiation pneumonitis developed in cases with a measured LMDY-90 lower than 12Gy.

2 March 2021 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
MSMartina Stella
Martina Stella
ABArthur Johannes Anthonius Theodorus Braat
Arthur Johannes Anthonius Theodorus Braat
MLMarnix G.E.H. Lam Lam
Marnix G.E.H. Lam Lam
HJHugo W. A. M. De Jong
Hugo W. A. M. De Jong
RRRob van Rooij
Rob van Rooij
Background: High activities of holmium-166 (166Ho)–labeled microspheres are used for therapeutic radioembolization, ideally directly followed by SPECT imaging for dosimetry purposes. The resulting high-count rate potentially impacts dead time, affecting the image quality and dosimetric accuracy. This study assesses gamma camera performance and SPECT image quality at high 166Ho activities of several GBq. To this purpose, the liver compartment, including two tumors, of an anthropomorphic phantom was filled with 166Ho-chloride, with a tumor to non-tumorous liver activity concentration ratio of 10:1. Multiple SPECT/CT scans were acquired over a range of activities up to 2.7 GBq. Images were reconstructed using a commercially available protocol incorporating attenuation and scatter correction. Dead time effects were assessed from the observed count rate in the photopeak (81 keV, 15% width) and upper scatter (118 keV, 12% width) window. Post reconstruction, each image was scaled with an individual conversion factor to match the known total activity in the phantom at scanning time. The resulting activity concentration was measured in the tumors and non-tumorous liver. The image quality as a function of activity was assessed by a visual check of the absence of artifacts by a nuclear medicine physician. The apparent lung shunt fraction (nonzero due to scatter) was estimated on planar and SPECT images. Results: A 20% count loss due to dead time was observed around 0.7 GBq in the photopeak window. Independent of the count losses, the measured activity concentration was up to 100% of the real value for non-tumorous liver, when reconstructions were normalized to the known activity at scanning time. However, for tumor spheres, activity concentration recovery was ~80% at the lowest activity, decreasing with increasing activity in the phantom. Measured lung shunt fractions were relatively constant over the considered activity range. Conclusions: At high 166Ho count rate, all images, visually assessed, presented no artifacts, even at considerable dead time losses. A quantitative evaluation revealed the possibility of reliable dosimetry within the healthy liver, as long as a post-reconstruction scaling to scanning activity is applied. Reliable tumor dosimetry, instead, remained hampered by the dead time.