Ali Dahaghin

Dr. Ali Dahaghin

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
ADAli Dahaghin
Ali Dahaghin
MSMilad Salimibani
Milad Salimibani
ABAgnieszka Boszczyk
Agnieszka Boszczyk
AJAgnieszka Jóźwik
Agnieszka Jóźwik
MSMarta Skrok
Marta Skrok
DSDamian Siedlecki
Damian Siedlecki
Introduction: Crystalline lens overshooting refers to a situation in which the lens momentarily shifts too much from its typical location immediately after stopping the rotational movement of the eye globe. This movement can be observed using an optical technique called Purkinje imaging.Methods: In this work, an experimental setup was designed to reproduce this effect ex vivo using a fresh porcine eye. The sample was rotated 90° around its centroid using a high-velocity rotation stage, and the Purkinje image sequences were recorded, allowing us to quantify the overshooting effect. The numerical part of the study consisted of developing a computational model of the eye, based on the finite element method, that allowed us to understand the biomechanical behavior of the different tissues in this dynamic scenario. A 2D fluid–structure interaction model of the porcine eye globe, considering both the solid parts and humors, was created to reproduce the experimental outcomes.Results: Outputs of the simulation were analyzed using an optical simulation software package to assess whether the mechanical model behaves optically like the real ex vivo eye. The simulation predicted the experimental results by carefully adjusting the mechanical properties of the zonular fibers and the damping factor.Conclusion: This study effectively demonstrates the importance of characterizing the dynamic mechanical properties of the eye tissues to properly comprehend and predict the overshooting effect.

25 March 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ADAli Dahaghin
Ali Dahaghin
MSMilad Salimi
Milad Salimi
ABAgnieszka Boszczyk
Agnieszka Boszczyk
JGJorge Grasa
Jorge Grasa
DSDamian Siedlecki
Damian Siedlecki
This study addresses a crucial knowledge gap by investigating the impact of intraocular pressure (IOP) on the wobbling characteristics of the crystalline lens in an ex vivo setting. It utilizes previous validated computational porcine eye models, which offer anatomical and physiological similarities to the human eye. These models incorporate fluid-structure interaction (FSI) to simulate the mechanical interaction between the fluids of the eye and the solid structures. Simulations were conducted under constant mechanical properties and boundary conditions, allowing for precise quantification of lens wobbling behavior with varying IOP levels. Various trends in lens displacement were observed at various IOP levels, revealing significant variations in both magnitude and duration. The results demonstrate the central role of intraocular pressure in influencing lens overshooting during rotational motion, with potential clinical implications. The observed lens displacement patterns, particularly in conditions like glaucoma, underscore the importance of considering IOP as a critical factor in understanding ocular biomechanics. Beyond immediate biomechanical relevance, the study’s findings suggest the potential use of the Purkinje imaging system as a non-invasive method for IOP estimation based on lens overshoot as an “inverse solution” strategy. This non-invasive imaging technique offers a promising alternative to traditional methods, minimizing patient discomfort and potentially enhancing measurement precision.

6 November 2026 in Experimental Eye Research
Verified
Journal Article
Open access
ADAli Dahaghin
Ali Dahaghin
FMFatemeh Mousavi
Fatemeh Mousavi
DDDariusz Danel
Dariusz Danel