The fabrication process of pretensioned prestressed concrete (PC) girders involves temperature changes, which affect the effective prestress and mechanical properties of the girders. Currently, there is a lack of a holistic understanding and accurate calculation methods for the prestress variation due to temperature change (PVTC), leading to technical challenges in calculating effective prestress in pretensioned PC girders. This study investigates the PVTC in three stages considering the time-varying interaction between concrete and tendons, proposes a new method to consider the effect of a deviator on the PVTC of a bent tendon, conducts an experimental study to validate the theoretical analysis, and develops measures for reducing the PVTC. The results show that the presented method provides reasonable predictions of PVTC, and the PVTC of the girder with steam curing is up to 80.3 MPa. Based on the presented method, measures for reducing the PVTC are proposed. This study provides new insights into computing the PVTC and improves the design and fabrication of pretensioned PC girders.
This paper investigates the interfacial bonding behavior between high toughness resin concrete with steel wire mesh (HTRCS) and concrete. A total of five sets of fifteen double shear specimens were tested for parameters including concrete strength and material properties of HTRCS composites. The test results showed that the failure mode of DS1 specimens was partial debonding and fracture, and the rest of the specimens were the fracture of HTRCS. The concrete strength and reinforcement ratios of HTRCS composites were positively correlated with interfacial adhesion properties. When the concrete strength was increased from C30 to C40 and C50, the ultimate load increased by 43.4% and 43.2%, respectively. The ultimate load capacity increased by 32.1%, with the reinforcement ratio of HTRCS composites increasing from 1.05% to 1.83%. Moreover, the bonding slip model and the bearing capacity formula for the interface between HTRCS composites and concrete were proposed, and the calculation values were in good agreement with the test values, with an average value of 0.978.
23 January 2024 in Case Studies in Construction Materials
In this paper, an experimental and theoretical study on the uniaxial tensile behavior of a fiber-reinforced polymer (FRP) grid-engineered cementitious composite (ECC) composite layer is described. Based on the test parameters, including the ECC material properties, the ECC cross-sectional area and the FRP grid cross-sectional area, three groups of ECC specimens and six groups of composite layer specimens were tested to reveal their joint action mechanism and tensile behavior. The experimental results showed two failure modes: fibers were pulled off or pulled out in the ECC specimens, and in the composite layer specimens, part of the fiber bars in the FRP grid was pulled off. The stress–strain curves show three stages: the elastic stage, softening stage and hardening stage. Due to the reinforcement of the FRP grid, the ultimate stress of the composite layer increased significantly compared with that of the ECC specimens. The composite layer softening strain was primarily related to the ECC softening strain, and the ultimate strain was primarily related to the FRP grid fracture strain. Moreover, a three-stage model was proposed to predict the stressstrain relationship, exhibiting a higher prediction accuracy and smaller dispersion compared with the three existing models.