Mechanical properties play a key role in the failure of dental implants. Dental implants require fatigue life testing before clinical application, but this process takes a lot of time. This study investigated the effect of various loading angles and implant lengths on the static fracture and fatigue life of dental implants. Implants with lengths of 9 mm and 11 mm were prepared. Static fracture tests and dynamic fatigue life tests were performed under three loading angles (30°, 40°, and 50°), and the level arm and bending moment were measured. After that, the fracture morphology and fracture mode of the implant were observed. The results showed that 9 mm length implants have a higher static failure load and can withstand greater bending moments, while 11 mm length implants have a longer fatigue life. In addition, as the loading angle increases, the static strength and bending moment decrease linearly, and the fatigue life shows an exponential decrease at a rate of three times. Increasing the loading angle reduces the time of the implant fatigue test, which may be an effective method to improve the efficiency of the experiment.
24 February 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Cathode spot motion influences the physical characteristics of arc plasma and the related macroparticles (MPs) in resultant films; these MPs limit the application of arc ion plating (AIP). In this paper, a scanning radial magnetic field (SRMF) was applied to the cathode surface to control the cathode spot motion and reduce the MP contamination in the deposited films. It was shown that film surface morphologies prepared using SRMF were better than those using a static radial magnetic field (RMF). The improvement was greater with increased scanning range and frequency. Using SRMF, cathode spot motion was confined to a spiral trajectory on the cathode surface and the spots moved over a large area and at a fast-moving velocity. Both the large moving area and the fast velocity decreased the temperature on the cathode surface and thus reduced the emission of the MPs.
In recent years, studies on the surface of titanium implants have shown that hydrophilic properties have a positive effect on bone binding, warranting further investigation into the maintenance and restoration of hydrophilic properties. In this work, a hydrophilic surface was obtained by plasma oxidation on the surface of sandblasted and acid-etched (SLA) titanium discs. We aimed to determine the effect of sodium hydroxide (NaOH) treatment on the maintenance and restoration of the surface hydrophilicity of titanium discs, as well as the relationship between the changes in hydrophilic properties on titanium surfaces and their biological properties. The results show that the treatment of hydrophilic surfaces with SLA, plasma oxidation, and NaOH treatments tend to enhance the early stages of cell adhesion, proliferation, and differentiation. Those results provide important guidance that SLA, plasma oxidation, and NaOH treatments can be used to restore the hydrophilic property of Ti that has been stored under room temperature and atmospheric pressure conditions.
Screw loosening is one of the most common clinical problems of dental implants. Research on the influencing factors of screw loosening is very important to prevent screw loosening. The purpose of this in vitro study was to evaluate the influence of liquid contamination on the screw loosening. According to the contamination condition, forty-five abutment screws were divided into three groups (n = 15): no contamination, artificial saliva contamination, and mouthwash contamination. The preload and friction coefficient of the abutment screws were recorded. Then, the reverse torque values (RTVs) and settlement were measured after 3.0 × 105 and 6.0 × 105 cycles. The surface wear of the screws was analyzed. Finally, the stress distribution of the abutment screws was calculated by finite element analysis (FEA). The results showed that fluid contamination reduced the friction coefficient, increased the preload, decrease the settlement, improved resistance to screw loosening, and reduced wear on the thread surface. Appropriate antimicrobial lubrication may improve the anti-loosening performance of abutment screws and prevent excessive wear on the threaded surface.
CrAlN and CrAlBN coatings were prepared on the surface of high-speed steel and shaper cutter by physical vapor deposition (PVD) technique using arc ion source. In the process of coating preparation, the adhesive layers were deposited by low bias voltage (−40 V) and the working layers are deposited by high bias voltage (−130 V). The effects of the addition of B element on the microstructure, hardness, elastic modulus and wear resistance of CrAlBN coating were studied. The results show that B element and its compounds exist in amorphous form in the coating, resulting in lattice distortion of the coating, increase of coating hardness to 37.1 GPa, and decrease of elastic modulus to 406.2 GPa. The addition of B element increases the uniformity of the columnar structure distribution and decreases the width of the columnar structure and grain size. The resistance to elastic deformation and plastic deformation of CrAlBN coating is improved, the wear resistance is improved. The performance of CrAlN and CrAlBN coatings on shaper cutter was studied. It was found that the main failure mode of shaper cutters is boundary wear and the wear mechanism of coatings had changed obviously. CrAlBN coating is mainly due to fatigue induced failure, accompanied by some diffusion wear. The addition of B element makes the CrAlBN coating have excellent resistance to oxidative wear, abrasive wear and diffusion wear during cutting. The results show that the addition of B element can improve the microstructure and mechanical properties of CrAlN coating, and the preparation of CrAlBN coating on the surface of the shaper cutter can significantly improve the service life of the coated shaper cutter, which has significance for the development of the shaper cutter industry.