Mechanical properties play a key role in the failure of dental implants. Dental implants require fatigue life testing before clinical application, but this process takes a lot of time. This study investigated the effect of various loading angles and implant lengths on the static fracture and fatigue life of dental implants. Implants with lengths of 9 mm and 11 mm were prepared. Static fracture tests and dynamic fatigue life tests were performed under three loading angles (30°, 40°, and 50°), and the level arm and bending moment were measured. After that, the fracture morphology and fracture mode of the implant were observed. The results showed that 9 mm length implants have a higher static failure load and can withstand greater bending moments, while 11 mm length implants have a longer fatigue life. In addition, as the loading angle increases, the static strength and bending moment decrease linearly, and the fatigue life shows an exponential decrease at a rate of three times. Increasing the loading angle reduces the time of the implant fatigue test, which may be an effective method to improve the efficiency of the experiment.
24 February 2022 in Journal of the Mechanical Behavior of Biomedical Materials
The traditional predictive model for remaining useful life predictions cannot achieve adaptiveness, which is one of the main problems of said predictions. This paper proposes a LightGBM-based Remaining useful life (RUL) prediction method which considers the process and machining state. Firstly, a multi-information fusion strategy that can effectively reduce the model error and improve the generalization ability of the model is proposed. Secondly, a preprocessing method for improving the time precision and small-time granularity of feature extraction while avoiding dimensional explosion is proposed. Thirdly, an importance coefficient and a custom loss function related to the process and machining state are proposed. Finally, using the processing data of actual tool life cycle, through five evaluation indexes and 25 sets of contrast experiments, the superiority and effectiveness of the proposed method are verified.
Plasma oxidation could produce an oxidized surface, resulting in a graded TiO2−x film layer and significantly improving dental implant hydrophilicity and biocompatibility. Unfortunately, these features are gradually lost by the influence of the environment. In this study, alkali storage was used to improve these characteristics at room temperature. Titanium samples were divided into sandblasting acid-etching (SLA), oxidation (SLA samples that were oxidized), and storage (SLA samples that were oxidized and stored in 0.1 mol/L NaOH solution) groups. We measured the surface properties of each group, including the roughness, chemical composition, and hydrophilicity of these materials. We investigated the effects of titanium storage on cell responses, including cell attachment, proliferation, differentiation. We also investigated the osseointegration of the stored titanium implants. The results showed that the storage process maintains the superhydrophilic properties of oxidation treatment. Oxidized samples promoted cell responses. The descending order of biocompatibility was storage > oxidation > SLA. Furthermore, oxidation and alkali storage had significant effects on bone growth at the early stage of the implant. These results suggested that alkali storage can suitably maintain the surface characteristics of plasma oxidation, and the combination of oxidation and storage treatment can improve the primary implant stability.