Matthew Mckay Niichel

Mr. Matthew Mckay Niichel

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MNMatthew Mckay Niichel
Matthew Mckay Niichel
SCStylianos Chatzidakis
Stylianos Chatzidakis
Modeling the response of gamma detectors has long been a challenge within the nuclear community. Significant research has been conducted to digitally replicate instruments that can cost over USD 100,000 and are difficult to operate outside of a laboratory setting. The large cost and availability prevent some from making use of such equipment. Subsequently, there have been multiple attempts to create cost-effective codes that replicate the response of sodium-iodide and high-purity germanium detectors for data derivation related to gamma-ray interaction with matter. While robust programs do exist, they are often subject to export controls and/or they are not intuitive to use. Through the use of hybrid Monte Carlo methods, MATLAB can be used to produce a fast first-order response of various gamma-ray detectors. The combination of a graphical user interface with a numerical-based script allows for open-source and intuitive code. When benchmarked with experimental data from Co-60, Cs-137, and Na-22, the code can numerically calculate a response comparable to experimental and industry-standard response codes. Evidence supports both savings in computational requirements and the inclusion of an intuitive user experience that does not heavily compromise data when compared to other standard codes, such as MCNP and GADRAS, or experimental results. When the application is installed on a Dell Intel i7 computer with 16 cores, the average time to simulate the benchmarked isotopes is 0.26 s. Installation on an HP Intel i7 four-core machine runs the same isotopes in 1.63 s. The results indicate that simple gamma detectors can be modeled in an open-source format. The anticipation for the MATLAB application is to be a tool that can be easily accessible and provide datasets for use in an academic setting requiring gamma-ray detectors. Ultimately, this article provides evidence that hybrid Monte Carlo codes in an open-source format can benefit the nuclear community in both computational time and up-front cost for access.

6 June 2025 in Instruments
Verified
Journal Article
Open access
PDF file
MNMatthew Mckay Niichel
Matthew Mckay Niichel
VTVasileios Theos
Vasileios Theos
RMRiley Madden
Riley Madden
HPHannah Kay Pike
Hannah Kay Pike
TMTrue Miller
True Miller
SCStylianos Chatzidakis
Stylianos Chatzidakis
First demonstrated in 1942, subcritical and zero-power critical assemblies, also known as piles, are a fundamental tool for research and education at universities. Traditionally, their role has been primarily instructional and for measuring the fundamental properties of neutron diffusion and transport. However, these assemblies could hold potential for modern applications and nuclear research. The Purdue University subcritical pile previously lacked a substantial testing volume, limiting its utility to simple neutron activation experiments for the purpose of undergraduate education. Following the design and addition of a mechanical and electrical testbed, this paper aims to provide an overview of the testbed design and characterize the neutron flux of the rearranged Purdue subcritical pile, justifying its use as a modern scientific instrument. The newly installed 1.5 × 105 cubic-centimeter volume testbed enables a systematic investigation of neutron and gamma effects on materials and the generation of a comprehensive data set with the potential for machine learning applications. The neutron flux throughout the pile is measured using gold-197 and indium-115 foil activation alongside cadmium-covered foils for two-group neutron energy classification. The neutron flux measurements are then used to benchmark a detailed geometrically and materialistically accurate Monte Carlo model using OpenMC 0.15.0 and MCNP 6.3. The experimental measurements reveal that the testbed has a neutron environment with a total neutron flux approaching 9.5 × 103 n/cm2 × s and a thermal flux of 6.5 × 103 n/cm2 × s. This work establishes that the modified Purdue subcritical pile can provide fair neutron and gamma fluxes within a large volume to enable the radiation testing of integral electronic components and can be a versatile research instrument with the potential to support material testing and limited isotope activation, while generating valuable training data sets for machine learning algorithms in nuclear applications.

22 December 2025 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MNMatthew Mckay Niichel
Matthew Mckay Niichel
TMTrue Miller
True Miller
BJBrian Jowers
Brian Jowers
RCR. Cooper
R. Cooper
SCStylianos Chatzidakis
Stylianos Chatzidakis
Radiation testing of microelectronics remains essential for ensuring reliability in environments such as space and nuclear power systems. One critical component found in many systems is the metal oxide semiconductor field-effect transistor (MOSFET). While work has been conducted on early MOSFET designs, there remains a gap in three key areas: testing modern power MOSFETs, collecting live test data, and evaluating components in combined radiation environments. Using modern components ensures that systems currently in use, both public and private, are better protected against radiation damage. Live monitoring allows observation of single-event effects and transient behavior not detectable through post-irradiation analysis. Additionally, conducting experiments in fission-spectrum neutron and gamma environments better replicates real-world conditions. While the literature addresses each of these topics separately, this work combines them by live-testing a boost converter circuit composed of a MAX1932 gate driver and a BSS119N N-type MOSFET under both neutron and gamma radiation. Testing was performed at the Purdue University Reactor Number One (PUR-1) and the Hopewell cobalt-60 irradiator, evaluating the circuit’s response to gamma total ionizing dose (TID) and thermal neutron-induced transients. Live monitoring displayed real-time transients, degradation, and recovery behavior. Results indicate gamma radiation plays a dominant role in circuit degradation. However, when considering the dose-dependent degradation, the combined radiation environment of PUR-1 induces failure with 34.8% less dose when compared to the Co-60. Suggesting neutron activation is contributing to secondary gamma dose or boron-10 (n,α) reaction damage. While Co-60 testing remains critical, thermal neutron facilities may offer a useful, cost-effective screening method for identifying gamma-sensitive components.

9 January 2024 in Nuclear Science and Technology Open Research
Verified
Journal Article
Open access
MNMatthew Mckay Niichel
Matthew Mckay Niichel
MBMary Brackett
Mary Brackett
BPBrant Purcell
Brant Purcell
DGDouglas Gologorsky
Douglas Gologorsky
BWBen Werve
Ben Werve
Background In the past two decades, the potential threat of a radiological dispersal device (RDD) or “dirty bomb,” which combines conventional explosives with radioactive material, has been a concern for counterterrorism efforts. The accessibility of radioactive materials used in various applications, such as medicine, industry, and research, makes RDDs a viable weapon of choice for terrorists. While the radiation released from an RDD is generally not lethal beyond a short range, the long-term health, environmental, and psychological effects of radiation release will have an impact on the future of a society. Providing proactive security measures will aid in the deterrence of potential radiological terrorist threats. Methods The use of commercial off-the-shelf detectors and GPS modules can be integrated with software to provide the approximate location of a radioactive anomaly. With the strategic placement of a circular array of 4-inch × 4-inch Thallium dopped Sodium-Iodide (NaI) in a façade of a full trashcan, it is possible to determine if, when, and the general direction of a hand- carried threat entering a venue. A supplemental detector containing a Cesium-Iodide (CsI) crystal and a GPS module fitted to a plate carrier vest can further refine the location of a threat. In tandem, these two designs are capable of providing the RDD screening that is currently lacking in public. Conclusions While a true threat may contain a radiation source well in the hundreds of Curies, the designs selected are tested and calibrated to 1-microcurie button sources. Which provides scaled results that indicate the possibility for the deployment of such a detection scheme in a venue. Although the devices tested are limited by commercial GPS resolution, the ability for both designs to determine the presence and approximate location of a button source within 10 feet is promising for further larger scale tests.

11 March 2025 in arXiv
Verified
Preprint
Open access
PDF file
MNMatthew Mckay Niichel
Matthew Mckay Niichel
SCStylianos Chatzidakis
Stylianos Chatzidakis
One of the persisting challenges associated with the peaceful use of the atom is monitoring the subsequent radiation. For example, nuclear power plants need environmental monitoring to ensure public trust. While this may be conducted by the frequent monitoring of low-cost thermoluminescent dosimeters placed in concentric rings around the plant, there have been several solutions for a modernized real-time digital alternative to the TLD. The Scatterable Radiation Monitoring device is an STM32 microprocessor-based design aiming at the wireless transmission of environmental radiation data.

6 June 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
MNMatthew Mckay Niichel
Matthew Mckay Niichel
RMRiley Madden
Riley Madden
HPHannah Kay Pike
Hannah Kay Pike
TMTrue Miller
True Miller
BJBrian Jowers
Brian Jowers
VTVasileios Theos
Vasileios Theos
First demonstrated in 1942, subcritical and zero-power critical assemblies, also known as piles, are a fundamental tool for research and education at universities [1]. Traditionally, their role has been primarily instructional and for measuring fundamental properties of neutron diffusion and transport. However, these assemblies could hold potential for modern applications and nuclear research. The Purdue University subcritical pile previously lacked a substantial testing volume, limiting its utility to simple neutron activation experiments for the purpose of undergraduate education. Following the design and addition of a mechanical and electrical testbed, this paper aims to provide an overview of the testbed design and characterize the neutron flux of the rearranged Purdue subcritical pile, justifying its use as a modern scientific instrument. The newly installed 1.5E+05 cubic-centimeter volume testbed enables a systematic investigation of neutron and gamma effects on materials and the generation of a comprehensive dataset with the potential for machine learning applications. The neutron flux throughout the pile is measured using gold-197 and indium115 foil activation alongside cadmium-covered foils for two-group neutron energy classification. The neutron flux measurements are then used to benchmark a detailed geometric and materialistic accurate Monte Carlo model using OpenMC and MCNP6.3. The experimental measurements reveal the testbed has a neutron environment with a total neutron flux approaching 9.5E+03 n/cm^2*s and a thermal flux of 6.5E+03 n/cm^2*s. This work establishes that the modified Purdue subcritical pile can provide fair neutron and gamma fluxes within a large volume to enable radiation testing of integral electronic components and as a versatile research instrument with the potential to support material testing and limited isotope activation, while generating valuable training datasets for machine learning algorithms in nuclear applications.