Ileana Pirovano

Ms. Ileana Pirovano

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CBCristina Brambilla
Cristina Brambilla
IPIleana Pirovano
Ileana Pirovano
RMRobert Mihai Mira
Robert Mihai Mira
GRGiovanna Rizzo
Giovanna Rizzo
Alessandro ScanoAlessandro Scano
Alessandro Scano
Alfonso MastropietroAlfonso Mastropietro
Alfonso Mastropietro
Electroencephalography (EEG) and electromyography (EMG) are widespread and well-known quantitative techniques used for gathering biological signals at cortical and muscular levels, respectively. Indeed, they provide relevant insights for increasing knowledge in different domains, such as physical and cognitive, and research fields, including neuromotor rehabilitation. So far, EEG and EMG techniques have been independently exploited to guide or assess the outcome of the rehabilitation, preferring one technique over the other according to the aim of the investigation. More recently, the combination of EEG and EMG started to be considered as a potential breakthrough approach to improve rehabilitation effectiveness. However, since it is a relatively recent research field, we observed that no comprehensive reviews available nor standard procedures and setups for simultaneous acquisitions and processing have been identified. Consequently, this paper presents a systematic review of EEG and EMG applications specifically aimed at evaluating and assessing neuromotor performance, focusing on cortico-muscular interactions in the rehabilitation field. A total of 213 articles were identified from scientific databases, and, following rigorous scrutiny, 55 were analyzed in detail in this review. Most of the applications are focused on the study of stroke patients, and the rehabilitation target is usually on the upper or lower limbs. Regarding the methodological approaches used to acquire and process data, our results show that a simultaneous EEG and EMG acquisition is quite common in the field, but it is mostly performed with EMG as a support technique for more specific EEG approaches. Non-specific processing methods such as EEG-EMG coherence are used to provide combined EEG/EMG signal analysis, but rarely both signals are analyzed using state-of-the-art techniques that are gold-standard in each of the two domains. Future directions may be oriented toward multi-domain approaches able to exploit the full potential of combined EEG and EMG, for example targeting a wider range of pathologies and implementing more structured clinical trials to confirm the results of the current pilot studies.

19 September 2023 in International Journal of Human–Computer Interaction
Verified
Journal Article
Open access
MMMarta Mondellini
Marta Mondellini
IPIleana Pirovano
Ileana Pirovano
VCVera Colombo
Vera Colombo
SASara Arlati
Sara Arlati
MSMarco Sacco
Marco Sacco
Alfonso MastropietroAlfonso Mastropietro
Alfonso Mastropietro

17 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Rebecca ReRebecca Re
Rebecca Re
IPIleana Pirovano
Ileana Pirovano
DCDavide Contini
Davide Contini
Lorenzo SpinelliLorenzo Spinelli
Lorenzo Spinelli
Alessandro TorricelliAlessandro Torricelli
Alessandro Torricelli
Measurement of muscle oxidative metabolism is of interest for monitoring the training status in athletes and the rehabilitation process in patients. Time domain near infrared spectroscopy (TD NIRS) is an optical technique that allows the non-invasive measurement of the hemodynamic parameters in muscular tissue: concentrations of oxy- and deoxy-hemoglobin, total hemoglobin content, and tissue oxygen saturation. In this paper, we present a novel TD NIRS medical device for muscle oxidative metabolism. A custom-printed 3D probe, able to host optical elements for signal acquisition from muscle, was develop for TD NIRS in vivo measurements. The system was widely characterized on solid phantoms and during in vivo protocols on healthy subjects. In particular, we tested the in vivo repeatability of the measurements to quantify the error that we can have by repositioning the probe. Furthermore, we considered a series of acquisitions on different muscles that were not yet previously performed with this custom probe: a venous-arterial cuff occlusion of the arm muscle, a cycling exercise, and an isometric contraction of the vastus lateralis.

22 December 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
IPIleana Pirovano
Ileana Pirovano
SPSimone Porcelli
Simone Porcelli
RRRebecca Re
Rebecca Re
LSLorenzo Spinelli
Lorenzo Spinelli
DCDavide Contini
Davide Contini
ATAlessandro Torricelli
Alessandro Torricelli
We propose a quantitative and systematic investigation of the differential pathlength factor (DPF) behavior for skeletal muscles and its dependence on different factors, such as the subcutaneous adipose tissue thickness (ATT), the variations of the tissue absorption (µa) and reduced scattering (µ′s) coefficients, and the source-detector distance. A time domain (TD) NIRS simulation study is performed in a two-layer geometry mimicking a human skeletal muscle with an overlying adipose tissue layer. The DPF decreases when µa increases, while it increases when µ′s increases. Moreover, a positive correlation between DPF and ATT is found. These results are supported by an in-vivo TD NIRS study on vastus lateralis and biceps brachii muscles of eleven subjects at rest, showing a high inter-subject and inter-muscle variability.

1 December 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
ASAlessandro Scano
Alessandro Scano
IPIleana Pirovano
Ileana Pirovano
MMM. E. Manunza
M. E. Manunza
LSLorenzo Spinelli
Lorenzo Spinelli
DCDavide Contini
Davide Contini
Rebecca ReRebecca Re
Rebecca Re
The effect of sustained fatigue during an upper limb isometric exercise is presented to investigate a group of healthy subjects with simultaneous time-domain (TD) NIRS and surface electromyography (sEMG) recordings on the deltoid lateralis muscle. The aim of the work was to understand which TD-NIRS parameters can be used as descriptors for sustained muscular fatigue, focusing on the slow phase of this process and using median frequency (MF) computed from sEMG as gold standard measure. It was found that oxygen saturation and deoxy-hemoglobin are slightly better descriptors of sustained fatigue, than oxy-hemoglobin, since they showed a higher correlation with MF, while total-hemoglobin correlation with MF was lower.

15 June 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
PLPranav Lanka
Pranav Lanka
LYLin Yang
Lin Yang
DODavid Orive-Miguel
David Orive-Miguel
JVJoshua D. Veesa
Joshua D. Veesa
STSusanna Tagliabue
Susanna Tagliabue
APAntonio Pifferi
Antonio Pifferi
Diffuse optics (DO) encompasses a range of photonics tools based on the study of random photon migration in highly scattering media—biological tissues in particular. Due to its unique features, DO is emerging as a powerful means for clinical or homecare diagnostics.1 The basic physics of DO is related to the detection of temporal or spatial alteration in photon distribution re-emitted on the tissue surface.2 Due to the low power (typically few mW) of injected near-infrared light (600- to 1100-nm range), DO is inherently noninvasive. The photon temporal (or spatial) distribution carries information on the absorption—ultimately related to tissue chemical composition, such as water, lipid, collagen content, oxy- and deoxy-hemoglobin concentration, cytochrome c-oxidase3—and scattering properties—linked to tissue microstructure. Further, DO is one of the few noninvasive modalities capable of providing functional information, e.g., brain or muscle activation.4 It can be operated noncontact through remote light illumination and collection.5 It explores the tissue well below the skin at depths of up to 2 to 4 cm. It can provide quantitative operator-independent assessment of the tissue status, such as hemoglobin oxygenation level in the brain. Finally, it is highly scalable, sharing the same technology from large clinical tomographic systems down to wearable devices or homecare appliances.6 For all these aspects, DO is attracting more and more interest in many fields, such as monitoring vital signs like brain oxygenation in critical care or during interventions,7 tumor diagnostics as for breast cancer,8 investigating the impact of lifestyle and nutrition on our body,9 or other fields such as neuroscience and psychology,10 sports, and leisure.11 Even further, the operator independence, the depth sensitivity, and the scalability in addition to noninvasiveness make this option attractive for telemedicine and homecare of patients remotely.