Michael Vinther

Dr. Michael Vinther

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
MVMichael Vinther
Michael Vinther
NRNiels Risum
Niels Risum
JSJesper Hastrup Svendsen
Jesper Hastrup Svendsen
RMRasmus Møgelvang
Rasmus Møgelvang
BPBerit Thornvig Philbert
Berit Thornvig Philbert

15 April 2016 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
TBTor Biering-Sørensen
Tor Biering-Sørensen
FOFlemming Javier Olsen
Flemming Javier Olsen
KSKatrine Storm
Katrine Storm
TFThomas Fritz-Hansen
Thomas Fritz-Hansen
NONiels Thue Olsen
Niels Thue Olsen
NRNiels Risum
Niels Risum
Only 30% of patients receiving an implantable cardioverter defibrillator (ICD) for primary prevention receive appropriately therapy. We sought to investigate the value of tissue Doppler imaging (TDI) to predict ventricular tachycardia (VT), ventricular fibrillation (VF), and cardiovascular mortality (CVD) in patients with primary prevention ICD. In total, 151 ICD patients meeting primary prevention criteria and with no history of ventricular arrhythmias were included. All participants were examined by conventional 2D echocardiography and TDI echocardiography. Longitudinal systolic ( s ′), early diastolic ( e ′), and late diastolic ( a ′) myocardial velocities were measured using TDI at six mitral annular sites and averaged to provide global estimates. Forty patients experienced the combined endpoint of VT, VF, or CVD during a median follow-up of 2.3 years. Left ventricular ejection fraction, global longitudinal strain, E / e ′, global s ′, and global e ′ were not significantly different in patients who developed VT/VF/CVD compared with those who did not. In contrast, global a ′ was significantly lower in patients with an unfavourable outcome compared with those without (4.8 ± 2.0 vs. 5.7 ± 1.8 cm/s, P = 0.020). Global a ′ remained an independent predictor of VT/VF/CVD after multivariable adjustment for age, gender, β-blocker therapy, and deceleration time (HR = 1.25 [1.02, 1.54], P = 0.032). Regional analysis revealed that a depressed a ′ in the inferior wall drives the predictive capability of a ′. Late diastolic velocity by TDI seems to be a superior echocardiographic predictor of VT/VF/CVD in ischaemic cardiomyopathy. Additionally, impaired late diastolic velocity in the inferior myocardial wall seems to be a paramount marker of future VT/VF/CVD.

3 July 2018 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
SPSusanne S. Pedersen
Susanne S. Pedersen
SSSøren J. Skovbakke
Søren J. Skovbakke
UWUffe Kock Wiil
Uffe Kock Wiil
TSThomas Schmidt
Thomas Schmidt
RCRene Depont Christensen
Rene Depont Christensen
JNJens C. Nielsen
Jens C. Nielsen
In Denmark and other countries, there has been a shift in the management of patients with an implantable cardioverter defibrillator (ICD) with remote device monitoring largely replacing in-hospital visits. Less patient-nurse and patient-physician interaction may lead to gaps in patients’ quality of care and impede patients’ adaptation to living successfully with the ICD. A comprehensive eHealth intervention that include goal-setting, monitoring of symptoms of depression, anxiety, and quality of life, psychological treatment, information provision, supportive tools, online dialogues with nursing staff and access to an online community network, may help fill these gaps and be particularly beneficial to patients who suffer from anxiety and depression. This study will evaluate the effectiveness of the ACQUIRE-ICD care innovation, a comprehensive and interactive eHealth intervention, on patient-reported and clinical outcomes. The ACQUIRE-ICD study is a multicenter, prospective, two-arm, unblinded randomised controlled superiority trial that will enroll 478 patients implanted with a first-time ICD or ICD with cardiac synchronisation therapy (CRT-D) from the six implanting centers in Denmark. The trial will evaluate the clinical effectiveness and cost-effectiveness of the ACQUIRE-ICD care innovation, as add-on to usual care compared with usual care alone. The primary endpoint, device acceptance, assessed with the Florida Patient Acceptance Survey, is evaluated at 12 months’ post implant. Secondary endpoints, evaluated at 12 and 24 months’ post implant, include patient-reported outcomes, return to work, time to first ICD therapy and first hospitalisation, mortality and cost-effectiveness. The effectiveness of a comprehensive and interactive eHealth intervention that relies on patient-centred and personalised tools offered via a web-based platform targeted to patients with an ICD has not been assessed so far. The ACQUIRE-ICD care innovation promotes and facilitates that patients become active participants in the management of their disease, and as such addresses the need for a more patient-centered disease-management approach. If the care innovation proves to be beneficial to patients, it may not only increase patient empowerment and quality of life but also free up time for clinicians to care for more patients. The trial has been registered on https://clinicaltrials.gov/ct2/show/NCT02976961 on November 30, 2016 with registration number [ NCT02976961 ].

21 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ANAnna-Karin Numé
Anna-Karin Numé
NCNicolas Carlson
Nicolas Carlson
TGThomas A. Gerds
Thomas A. Gerds
EHEllen Holm
Ellen Holm
JPJannik Pallisgaard
Jannik Pallisgaard
MRMartin H. Ruwald
Martin H. Ruwald
Syncope could be related to high risk of falls and injury in adults, but documentation is sparse. We examined the association between syncope and subsequent fall-related injuries in a nationwide cohort. By cross-linkage of nationwide registers, all residents ≥18 years with a first-time diagnosis of syncope were identified between 1997–2012. Syncope patients were matched 1:1 with individuals from the general population. The absolute one-year risk of fall-related injuries, defined as fractures and traumatic head injuries requiring hospitalization, was calculated using Aalen-Johansen estimator. Ratios of the absolute one-year risk of fall-related injuries (ARR) were assessed by absolute risk regression analysis. We identified 125,763 patients with syncope: median age 65 years (interquartile range 46–78). At one year, follow-up was complete for 99.8% where a total of 8394 (6.7%) patients sustained a fall-related injury requiring hospitalization, of which 1606 (19.1%) suffered hip fracture. In the reference group, 4049 (3.2%) persons had a fall-related injury. The one-year ARR of a fall-related injury was 1.79 (95% confidence interval 1.72–1.87, P<0.001) in patients with syncope compared with the reference group; however, increased ARR was not exclusively in older patients. Factors independently associated with increased ARR of fall-related injuries in the syncope population were: injury in past 12 months, 2.39 (2.26–2.53, P<0.001), injury in relation to the syncope episode, 1.62 (1.49–1.77, P<0.001), and depression, 1.37 (1.30–1.45, P<0.001) Patients with syncope were at 80% increased risk of severe fall-related injuries within the year following discharge. Notably, increased risk was not exclusively in older patients.

21 August 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
OSOle Skov
Ole Skov
JJJens Brock Johansen
Jens Brock Johansen
JNJens Cosedis Nielsen
Jens Cosedis Nielsen
CLCharlotte E Larroudé
Charlotte E Larroudé
SRSam Riahi
Sam Riahi
SPSusanne S Pedersen
Susanne S Pedersen
Modern clinical management of patients with an implantable cardioverter defibrillator (ICD) largely consists of remote device monitoring, although a subset is at risk of mental health issues post-implantation. We compared a 12-month web-based intervention consisting of goal setting, monitoring of patients’ mental health—with a psychological intervention if needed—psychoeducational support from a nurse, and an online patient forum, with usual care on participants’ device acceptance 12 months after implantation. This national, multi-site, two-arm, non-blinded, randomized, controlled, superiority trial enrolled 478 first-time ICD recipients from all 6 implantation centres in Denmark. The primary endpoint was patient device acceptance measured by the Florida Patient Acceptance Survey (FPAS; general score range = 0–100, with higher scores indicating higher device acceptance) 12 months after implantation. Secondary endpoints included symptoms of depression and anxiety. The primary endpoint of device acceptance was not different between groups at 12 months [B = −2.67, 95% confidence interval (CI) (−5.62, 0.29), P = 0.08]. Furthermore, the secondary endpoint analyses showed no significant treatment effect on either depressive [B = −0.49, 95% CI (−1.19; 0.21), P = 0.17] or anxiety symptoms [B = −0.39, 95% CI (−0.96; 0.18), P = 0.18]. The web-based intervention as supplement to usual care did not improve patient device acceptance nor symptoms of anxiety and depression compared with usual care. This specific web-based intervention thus cannot be recommended as a standardized intervention in ICD patients.

25 July 2023 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
EHE V Højgaard
E V Højgaard
BPB T Philbert
B T Philbert
JLJ J Linde
J J Linde
UWU C Winsløw
U C Winsløw
JSJ H Svendsen
J H Svendsen
NRN Risum
N Risum
Aims: His-bundle pacing has emerged as a novel method to deliver cardiac resynchronization therapy (CRT). However, there are no data comparing conventional biventricular (BiV)-CRT with His-CRT with regard to effects on mechanical dyssynchrony and longitudinal contractile function. Methods and results: Patients with symptomatic heart failure, left ventricular ejection fraction ≤ 35%, and left bundle branch block (LBBB) by strict ECG criteria were randomized 1:1 to His-CRT or BiV-CRT. Two-dimensional strain echocardiography was performed prior to CRT implantation and at 6 months after implantation. Differences in changes in mechanical dyssynchrony (standard deviation of time-to-peak in 12 midventricular and basal segments) and regional longitudinal strain in the six left ventricular walls were compared between the BiV-CRT and His-CRT groups. In the on-treatment analysis, 31 received BiV-CRT and 19 His-CRT. In both groups, mechanical dyssynchrony was significantly reduced after 6 months [BiV group from 120 ms (±45) to 63 ms (±22), P < 0.001, and His group from 116 ms (±54) to 49 ms (±11), P < 0.001] but no significant differences in changes could be demonstrated between groups [−9.0 ms (−36; 18), P = 0.50]. Global longitudinal strain (GLS) improved in both groups [BiV group from −9.1% (±2.7) to −10.7% (±2.6), P = 0.02, and His group from −8.6% (±2.1) to −11.1% (±2.0), P < 0.001], but no significant differences in changes could be demonstrated from baseline to follow-up [−0.9% (−2.4; −0.6), P = 0.25] between groups. There were no regional differences between groups. Conclusion: In heart failure, patients with LBBB, BiV-CRT, and His-CRT have comparable effects with regard to improvements in mechanical dyssynchrony and longitudinal contractile function.