Pavel Elizarov

Pavel Elizarov

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
ALAlexey Lychagin
Alexey Lychagin
Andrey Anatolievich GritsyukAndrey Anatolievich Gritsyuk
Andrey Anatolievich Gritsyuk
MEMikhail Elizarov
Mikhail Elizarov
YRYaroslav Alekseevich Rukin
Yaroslav Alekseevich Rukin
AGAndrey Andreevich Gritsyuk
Andrey Andreevich Gritsyuk
RNRosenberg Nahum
Rosenberg Nahum
Background: Total Knee Arthroplasty (TKA) is a prevalent surgical procedure for treating severe knee arthritis, aiming to alleviate pain and restore function. Recent advancements have introduced computer-assisted (CAS) and robot-assisted (RA-TKA) surgical techniques as alternatives to conventional methods, promising improved accuracy and patient outcomes. However, comprehensive comparative studies evaluating the short-term outcomes and prostheses survivorship among these techniques are limited. We hypothesized that the outcome of RA-TKA and/or CAS- TKA is advantageous in function and prosthesis survivorship compared to manually implanted prostheses. Methods: This prospective controlled study compared the short-term outcomes and prostheses survivorship following TKA using conventional, CAS, and RA-TKA techniques. One hundred seventy-eight patients requiring TKA were randomly assigned to one of the three surgical groups. The primary outcomes were knee function (KSS knee score) and functional recovery (KSS function score), which were assessed before surgery three years postoperatively. Secondary outcomes included prosthesis alignment, knee range of movements, and complication rates. Survivorship analysis was conducted using Kaplan–Meier curves, with revision surgery as the endpoint. Results: While all three groups showed significant improvements in knee function postoperatively (p < 0.001), the CAS and RA-TKA groups demonstrated superior prosthetic alignment and higher survivorship rates than the conventional group (100%, 97%, and 96%, respectively). However, although the RA-TKA group had a maximal 100% survivorship rate, its knee score was significantly lower than following CAS and conventional techniques (mean 91 ± 3SD vs. mean 93 ± 3SD, p = 0.011). Conclusion: The RA-TKA technique offers advantages over conventional and CAS methods regarding alignment accuracy and short-term survivorship of TKA prostheses. Since short-term prosthesis survivorship indicates the foreseen rates of mid- and long-term survivorship, the current data have a promising indication of the improved TKA prosthesis’s long-term survivorship by implementing RA-TKA. According to the presented data, although the survival rates were 100%, 97%, and 96% in the three study groups, no clinical difference in the functional outcome was found despite the better mechanical alignment and higher survivorship in the group of patients treated by the RA-TKA.

15 September 2023 in Traumatology and Orthopedics of Russia
Verified
Journal Article
Open access
VMValeriy Y. Murylev
Valeriy Y. Murylev
GKGrigorii A. Kukovenko
Grigorii A. Kukovenko
PEPavel Elizarov
Pavel Elizarov
YRYaroslav A. Rukin
Yaroslav A. Rukin
AMAleksei Muzychenkov
Aleksei Muzychenkov
АРАрина
Арина
Background.The use of custom-made acetabular components is one of the promising methods for reconstruction of the acetabulum in cases of significant defects, including those associated with pelvic bone dissociation. It allows achieving stable fixation and restoring the biomechanics of the hip joint. Aimofthestudy to compare the results of using individually designed components, supportive antiprotrusion rings, augments, and hemispherical components in revision total hip arthroplasty for type IIIB bone defects according to Paprosky classification. Methods.The study analyzed the treatment outcomes of 90 patients with type IIIB bone defects who underwent revision total hip arthroplasty between 2017 and 2022. Patients were divided into three groups: the first group received individually designed acetabular components, the second group received augments with hemispheres, and the third group had antiprotrusion cages implanted. The analysis included the reasons for revision surgery, operation duration, blood loss volume, and type of revision procedure. Pain and functional outcomes were assessed with WOMAC, Harris Hip Score, and VAS scales. Results.3D-printed constructs were more frequently implanted in patients with pelvic bone dissociation. The first group showed a significantly positive dynamic in functional outcomes. Complications were diagnosed in 27 (30%) cases: joint instability (dislocation) in 10 (11.1%) patients, periprosthetic infection in 8 (8.8%), aseptic loosening in 4 (4.4%), and sciatic nerve neuropathy in 5 (5.5%) patients. The number of these complications was higher in the second and third groups of patients. Conclusion.Custom-made implants using 3D technologies are a preferable option for revision total hip arthroplasty in patients with type IIIB defects according to Paprosky classification, especially in cases of pelvic bone dissociation.

23 September 2022 in Traumatology and Orthopedics of Russia
Verified
Journal Article
Open access
PDF file
VMValery Yu. Murylev
Valery Yu. Murylev
ARAlexander I. Rudnev
Alexander I. Rudnev
GKGrigory A. Kukovenko
Grigory A. Kukovenko
PEPavel Elizarov
Pavel Elizarov
AMAleksei Muzychenkov
Aleksei Muzychenkov
SASemyon Sergeevich Alekseev
Semyon Sergeevich Alekseev
Periprosthetic infection (PJI) is one of the most frequent and devastating complications of total hip arthroplasty (THA). Early and accurate diagnosis of PJI allows timely initiation of treatment. Various diagnostic tools and algorithms for hip PJI diagnosis are described. The available serum (ESR, CRP, D-dimer, etc.) and synovial (alpha-defensin, leukocyte esterase, D-lactate) biomarkers are listed, as well as their combinations for the purpose of PJI verification. Combined serum and synovial tests can significantly improve the efficiency of PJI hip diagnosis.

30 December 2018 in Grekov's Bulletin of Surgery
Verified
Journal Article
Open access
PDF file
VMV. Yu. Murylev
V. Yu. Murylev
PEPavel Elizarov
Pavel Elizarov
AMA. V. Muzychenkov
A. V. Muzychenkov
YRYa. A. Rukin
Ya. A. Rukin
ADA. A. Dering
A. A. Dering
GRG. G. Rubin
G. G. Rubin
The objectiveof the study is to make the analysis of the results of total cement knee arthroplasty in the most difficult age group of 85–95 years old patients.Material and methods.40 patients with terminal knee arthrosis were selected based on their comorbidity.Results.Patients with the Charlson comorbidity index of 5–8 points need hospitalization for the treatment of aggravating somatic pathology, as preparation for a future knee arthroplasty. In the operated patients, the result on the KOOS was (76±7.19), and on the WOMAC was (151±4.83) a year after the arthroplasty.Сonclusion.Surgical intervention – total knee arthroplasty in patients of 85–95 years old is possible only if its risk is minimized.

15 June 2010 in N.N. Priorov Journal of Traumatology and Orthopedics
Verified
Journal Article
Open access
GKG M Kavalerskiy
G M Kavalerskiy
VMV Yu Murylev
V Yu Murylev
PEPavel Elizarov
Pavel Elizarov
AZA G Zhuchkov
A G Zhuchkov
LYL A Yakimov
L A Yakimov
ТИТерентьев Д И
Терентьев Д И
Experience in cement total knee arthroplasty using computer navigation is presented. There were 42 patients with severe deformities of knee, condyles as well as tibia and femur diaphyses. Five patients out of them had prior implanted hip endoprostheses on ipsilateral side in whom use of routine arthroplasty technique with guide was impossible. In such cases computer navigation allowed to achieve high-precise insertion of implant with provision of correct ligament balance and maintenance of all axes and angles. The terms of rehabilitation and functional results were similar to common cases of primary knee joint replacement using computer navigation.

4 July 2024 in Traumatology and Orthopedics of Russia
Verified
Journal Article
Open access
PDF file
VMValery Yu. Murylev
Valery Yu. Murylev
JPJavad Parvizi
Javad Parvizi
ARAlexander I. Rudnev
Alexander I. Rudnev
GKGrigory A. Kukovenko
Grigory A. Kukovenko
PEPavel Elizarov
Pavel Elizarov
ЕЕЕрохин Николай Евгеньевич
Ерохин Николай Евгеньевич
Background. Reinfection and recurrence of periprosthetic infection rates during the second stage of revision hip arthroplasty (RHA) remain quite high. Performing preoperative diagnostic aspiration in patients with the installed hip spacer is a controversial issue. Aims of the study: 1) to compare the diagnostic accuracy, specificity and sensitivity of the used infection markers as a part of preoperative diagnostic protocols in order to exclude reinfection in patients with installed hip spacer before the second stage of RHA; 2) to analyze and compare the microbiological spectrum obtained at the stages of RHA. Methods. Diagnostic accuracy parameters of the used infection markers were assessed in order to exclude reinfection/recurrence in 107 patients with installed hip spacer. All patients were divided into two groups. In Group 1 (prospective), blood tests as well as diagnostic aspiration of synovial fluid were performed within the extended diagnostic protocol. In Group 2 (retrospective), the examination was performed according to the screening preoperative diagnostic protocol including blood tests. The used reference range of inflammatory biomarkers was based on the “small criteria” of ICM 2018. According to the results of the intraoperative microbiological examination of peri-implant tissue samples at the first and second stages of RHA, the analysis of detected microflora was conducted in order to assess probable reinfection/recurrence. Results. According to the results of the intraoperative microbiologic examination during the second stage of RHA, reinfection was detected in 40% of cases: in Group 1 — 9 cases, in Group 2 — 31 case. Synovial fluid was obtained from 85% of cases when preoperative diagnostic aspiration was performed. Synovial fluid could not be obtained in 15% cases (dry joint). Conclusion. Performing preoperative diagnostic aspiration before the second stage of RHA in patients with the installed spacer allowed choosing correct treatment tactics in 9% of cases. The parameters of diagnostic accuracy accounted for 82,6%. In the structure of detected pathogens in case of recurrence and reinfection, the representatives of Gram-positive coagulase-negative flora were the most frequent.