Background.The use of custom-made acetabular components is one of the promising methods for reconstruction of the acetabulum in cases of significant defects, including those associated with pelvic bone dissociation. It allows achieving stable fixation and restoring the biomechanics of the hip joint. Aimofthestudy to compare the results of using individually designed components, supportive antiprotrusion rings, augments, and hemispherical components in revision total hip arthroplasty for type IIIB bone defects according to Paprosky classification. Methods.The study analyzed the treatment outcomes of 90 patients with type IIIB bone defects who underwent revision total hip arthroplasty between 2017 and 2022. Patients were divided into three groups: the first group received individually designed acetabular components, the second group received augments with hemispheres, and the third group had antiprotrusion cages implanted. The analysis included the reasons for revision surgery, operation duration, blood loss volume, and type of revision procedure. Pain and functional outcomes were assessed with WOMAC, Harris Hip Score, and VAS scales. Results.3D-printed constructs were more frequently implanted in patients with pelvic bone dissociation. The first group showed a significantly positive dynamic in functional outcomes. Complications were diagnosed in 27 (30%) cases: joint instability (dislocation) in 10 (11.1%) patients, periprosthetic infection in 8 (8.8%), aseptic loosening in 4 (4.4%), and sciatic nerve neuropathy in 5 (5.5%) patients. The number of these complications was higher in the second and third groups of patients. Conclusion.Custom-made implants using 3D technologies are a preferable option for revision total hip arthroplasty in patients with type IIIB defects according to Paprosky classification, especially in cases of pelvic bone dissociation.
23 September 2022 in Traumatology and Orthopedics of Russia
Periprosthetic infection (PJI) is one of the most frequent and devastating complications of total hip arthroplasty (THA). Early and accurate diagnosis of PJI allows timely initiation of treatment. Various diagnostic tools and algorithms for hip PJI diagnosis are described. The available serum (ESR, CRP, D-dimer, etc.) and synovial (alpha-defensin, leukocyte esterase, D-lactate) biomarkers are listed, as well as their combinations for the purpose of PJI verification. Combined serum and synovial tests can significantly improve the efficiency of PJI hip diagnosis.
26 December 2022 in Traumatology and Orthopedics of Russia
Background. Intra-articular injections of autologous platelet-rich plasma (PRP), which is a natural biological stimulant and affects various parts of the regenerative process, are often used in the treatment of adhesive capsulitis. Another line of using the reparative potential of biopolymers is the application of polynucleotides (PN), which, due to their effect on fibroblasts, are able to stimulate regeneration processes during adhesive capsulitis. Aim of study. To evaluate the clinical efficacy of intra-articular injections of autologous platelet-rich plasma and a polynucleotide-based drug in the complex therapy of shoulder adhesive capsulitis, depending on the stage of the disease. Methods. Performed prospective cohort study included 42 patients aged 47 to 60 years with the diagnosis of adhesive capsulitis. The duration of the disease varied from 3 months to 5 years. The patients were divided into 2 groups depending on the stage of the disease at the time of the treatment: 24 patients with the first stage of the disease (group AC1) and 18 patients with the second stage (AC2). Each group was divided into 2 subgroups of patients. In subgroups either PRP or PN were administered. The results were assessed 1 week, 1 month, 3 months after the start of the treatment. Evaluation of pain management efficacy was carried out using the visual-analog scale (VAS). The change in the quality of life of patients and the function of the shoulder joint were defined using the DASH questionnaire for assessing the function of the upper limb and the Simple Shoulder Test (SST). Results. The use of PRP made it possible to achieve pain relief regardless of the stage of the disease. Patients of the AC1 group had a progressive pain syndrome attenuation from 80 to 45 points according to the VAS scale during the first 7 days after the start of the treatment. On the contrary, patients of the AC2 group had a slight pain increase by the end of the 1st week, that was associated with growing physical activity of patients. In the group of patients treated with PN, all experienced pain regression after the first injection. 20% of patients had pain relief within 24-36 hours after the start of the treatment., Increased joint pain was registered in 2 (10%) patients, which passed spontaneously during the first day. Pain syndrome intensity decreased in patients with both stages of the disease. According to the VAS, it decreased from 90-80 to 65 points after the first injection within 4 days in the AC1 group. Patients of the AC2 group did not notice significant effect after the first injection. The second injection reduced the pain to 65-70 points. Conclusion. The effectiveness of PN-based drugs had no statistically significant difference from that of PRP, but their effect was achieved faster.
Background. Reinfection and recurrence of periprosthetic infection rates during the second stage of revision hip arthroplasty (RHA) remain quite high. Performing preoperative diagnostic aspiration in patients with the installed hip spacer is a controversial issue. Aims of the study: 1) to compare the diagnostic accuracy, specificity and sensitivity of the used infection markers as a part of preoperative diagnostic protocols in order to exclude reinfection in patients with installed hip spacer before the second stage of RHA; 2) to analyze and compare the microbiological spectrum obtained at the stages of RHA. Methods. Diagnostic accuracy parameters of the used infection markers were assessed in order to exclude reinfection/recurrence in 107 patients with installed hip spacer. All patients were divided into two groups. In Group 1 (prospective), blood tests as well as diagnostic aspiration of synovial fluid were performed within the extended diagnostic protocol. In Group 2 (retrospective), the examination was performed according to the screening preoperative diagnostic protocol including blood tests. The used reference range of inflammatory biomarkers was based on the “small criteria” of ICM 2018. According to the results of the intraoperative microbiological examination of peri-implant tissue samples at the first and second stages of RHA, the analysis of detected microflora was conducted in order to assess probable reinfection/recurrence. Results. According to the results of the intraoperative microbiologic examination during the second stage of RHA, reinfection was detected in 40% of cases: in Group 1 — 9 cases, in Group 2 — 31 case. Synovial fluid was obtained from 85% of cases when preoperative diagnostic aspiration was performed. Synovial fluid could not be obtained in 15% cases (dry joint). Conclusion. Performing preoperative diagnostic aspiration before the second stage of RHA in patients with the installed spacer allowed choosing correct treatment tactics in 9% of cases. The parameters of diagnostic accuracy accounted for 82,6%. In the structure of detected pathogens in case of recurrence and reinfection, the representatives of Gram-positive coagulase-negative flora were the most frequent.
Background Alpha defensin lateral flow (ADLF) test is a current accurate tool for detecting/excluding periprosthetic joint infection (PJI); however, its usage in patients with a hip joint spacer has not yet been fully studied.The purpose of the study was to determine the diagnostic parameters (accuracy, specificity, sensitivity, AUC) of the alpha-defensin lateral flow test as part of the reinfection verification in patients with a hip joint spacer in the second stage of revision hip arthroplasty (RHA).Material and methods In a prospective study the effectiveness of the intraoperative use of ADLF test was evaluated in 105 patients with hip joint spacers during the 2nd stage of revision hip arthroplasty (RHA). The standard microbiological examination of intraoperative samples of tissues and synovial fluid was accepted as the gold standard for re-infection diagnosis.Results The growth of microflora according to the results of intraoperative microbiological examination was detected in 24 (23 %) cases. The discrepancy in the results of intraoperative microbiological examination and the results of the ADLF test was found in 10 (11 %) cases. False positive and false negative cases were identified. ADLF test demonstrated 96.39 % specificity, 89.52 % accuracy and 63.64 % sensitivity. The AUC index was 0.8.Discussion ADLF test has good diagnostic indicators for the verification of PJI in patients after hip replacement. The use of ADLF test in patients with a hip joint spacer who continue antibacterial therapy allows the test to be performed in the 2nd stage of RHA. However, the results of ADLF test in patients during the 2nd stage of RHA show that additional studies are required.Conclusion The ADLF test, despite the divergent data from scientific publications, demonstrates high diagnostic value for intraoperative verification of reinfection in patients with a hip joint spacer, allowing timely correction of treatment tactics. "Dry tap", bloody synovial fluid, as well as weakly virulent coagulasenegative microflora, including in microbial associations, are limitations of the ADLF test application.