Objectives: To analyze Heart Team decisions and outcomes following failure of surgical aortic valve replacement (SAVR) prostheses. Methods: Patients undergoing re-operations following index SAVR (Redo-SAVR) and those undergoing valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) following SAVR were included in this study. Patients who underwent index SAVR and/or Redo-SAVR for endocarditis were excluded. Data are presented as medians and 25th–75th percentiles, or absolute numbers and percentages. Outcomes were analyzed in accordance to the VARC-3 criteria. Results: Between 01/2015 and 03/2021, 53 patients underwent Redo-SAVR, 103 patients ViV-TAVR. Mean EuroSCORE II was 5.7% (3.5–8.5) in the Redo-SAVR group and 9.2% (5.4–13.6) in the ViV group. In the Redo-SAVR group, 12 patients received aortic root enlargement (22.6%). Length of hospital and ICU stay was longer in the Redo-SAVR group (p < 0.001; p < 0.001), PGmax and PGmean were lower in the Redo-SAVR group as compared to the ViV-TAVR group (18 mmHg (10–30) vs. 26 mmHg (19–38), p < 0.001) (9 mmHg (6–15) vs. 15 mmHg (9–21), p < 0.001). A higher rate of paravalvular leakage was seen in the ViV-TAVR group (p = 0.013). VARC-3 Early Safety were comparable between the two populations (p = 0.343). Survival at 1 year and 5 years was 82% and 36% in the ViV-TAVR cohort and 84% and 77% in the Redo-SAVR cohort. The variables were patient age (OR 1.061; [95% CI 1.020–1.104], p = 0.004), coronary heart disease (OR 2.648; [95% CI 1.160–6.048], p = 0.021), and chronic renal insufficiency (OR 2.711; [95% CI 1.160–6.048], p = 0.021) showed a significant correlation to ViV-TAVR. Conclusions: Heart Team decisions are crucial in the treatment of patients with degenerated aortic bioprostheses and lead to a low mortality in both treatment paths thanks to patient-specific therapy planning. ViV-TAVR offers a treatment for elderly or intermediate-risk profile patients with comparable short-term mortality. However, this therapy is associated with increased pressure gradients and a high prevalence of paravalvular leakage. Redo-SAVR enables the surgical treatment of concomitant cardiac pathologies and allows anticipation for later VIV-TAVR by implanting the largest possible valve prostheses.
Background: Extracorporeal life support (ECLS) therapy for refractory postcardiotomy cardiogenic shock (rPCS) is associated with high early mortality rates. This study aimed to identify negative predictors of mid-term survival and to assess health-related quality of life (HRQoL) and recovery of the survivors. Methods: Between 2017 and 2020, 142 consecutive patients received ECLS therapy following cardiac surgery. The median age was 66.0 [57.0–73.0] years, 67.6% were male and the median EuroSCORE II was 10.5% [4.2–21.3]. In 48 patients, HRQoL was examined using the 36-Item Short Form Survey (SF-36) and the modified Rankin-Scale (mRS) at a median follow-up time of 2.2 [1.9–3.2] years. Results: Estimated survival rates at 3, 12, 24 and 36 months were 47%, 46%, 43% and 43% (SE: 4%). Multivariable Cox Proportional Hazard regression analysis revealed preoperative EuroSCORE II (p = 0.013), impaired renal function (p = 0.010), cardiopulmonary bypass duration (p = 0.015) and pre-ECLS lactate levels (p = 0.004) as independent predictors of mid-term mortality. At the time of follow-up, 83.3% of the survivors were free of moderate to severe disability (mRS < 3). SF-36 analysis showed a physical component summary of 45.5 ± 10.2 and a mental component summary of 50.6 ± 12.5. Conclusions: Considering the disease to be treated, ECLS for rPCS is associated with acceptable mid-term survival, health-related quality of life and functional status. Preoperative EuroSCORE II, impaired renal function, cardiopulmonary bypass duration and lactate levels prior to ECLS implantation were identified as negative predictors and should be included in the decision-making process.
Continuous-flow left ventricular assist devices have become an important treatment option for patients with advanced heart failure. However, adverse hemodynamic effects as consequence of an altered blood flow within the aorta and the aortic root remain a topic of concern. In this work, we investigated the influence of the outflow graft orientation on the hemodynamic profile and flow parameters within the thoracic aorta. Aortic models with different outflow graft orientations were designed and three-dimensional (3D) printed to mimic common implantation configurations and were integrated into a pulsatile mock circulatory flow loop. Assist device function was achieved using a rotary pump, replicating nonpulsatile, continuous support flows of 1–5 L/min. Flow velocity, wall shear stress, and pressure gradients were investigated for each configuration using sonography and four-dimensional (4D) flow magnetic resonance imaging. Mean wall shear stresses measured in 4D flow software were lowest for a graft inclination angle of 45°. Streamline visualization revealed areas of nonuniform, retrograde, and vortex flow in all models but most prominent for the aortic model with an outflow graft inclination of 60°. The insights gained from this research may aid in understanding clinical outcomes following assist device implantation and long-term mechanical circulatory support.