Linda Grefen

Dr. Linda Grefen

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2018 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
LGLinda Grefen
Linda Grefen
FKF. König
F. König
MGM. Grab
M. Grab
CHC. Hagl
C. Hagl
NTNikolaus Thierfelder
Nikolaus Thierfelder

17 March 2025 in Pediatric Research
Verified
Journal Article
Open access
PDF file
LGLinda Grefen
Linda Grefen
FRFelix Rudolf
Felix Rudolf
CHChristopher Herz
Christopher Herz
NHNikolaus A. Haas
Nikolaus A. Haas
AJAndré Jakob
André Jakob
MGMaximilian Grab
Maximilian Grab
Background: Evaluation of the impact of 3D-printed models on parental education and anxiety in parents of children with congenital heart disease (CHD) who are undergoing interventions or surgeries. Methods: A prospective randomized controlled trial was conducted at LMU University Hospital and the German Heart Center Munich. Parents ( n = 57) of pediatric CHD patients were randomized into two groups: a control group using standardized paper-based methods and an intervention group using additional 3D-printed models. Parental anxiety was assessed using the Visual Analog Scale (VAS) and the State-Trait Anxiety Inventory, while procedural understanding and satisfaction with the education were evaluated using custom-developed questionnaires. Results: Both educational methods significantly increased procedural understanding (control 77.5% to 92.3%; 3D model: 77% to 89.4%, p < 0.0001, respectively). Significant reduction of anxiety was observed in both groups, (VAS reduction control: −0.9, p = 0.0342; 3D model: −1.1, p = 0.0116). Parents with medical background or those informed by pediatricians had lower anxiety whereas those seeking information online exhibited higher anxiety levels. Conclusion: Both educational methods significantly reduced parental anxiety and improved procedural understanding. 3D-printed models were well-received and will be integrated into routine practice to enhance education on CHD procedures and optimize physician-parent communication. Impact Statement: Using additional 3D-printed models of congenital heart defects significantly reduces parental anxiety and increases procedural understanding of complex interventions or surgeries. Physicians are in desperate need of new visualization methods for an efficient patient education. This study underscores the need for tailored educational and psychological support for parents based on their previous experiences.

1 January 2025 in Journal of Applied Biomaterials & Functional Materials
Verified
Journal Article
Open access
JKJulia Krammer
Julia Krammer
MPMaximilian Pichlmaier
Maximilian Pichlmaier
JSJan Stana
Jan Stana
CHChristian Hagl
Christian Hagl
SPSven Peterss
Sven Peterss
LGLinda Grefen
Linda Grefen
Commercially available Dacron (woven polyester) grafts are used for routine open surgical repair of thoracic aortic aneurysms. Despite durable and biocompatible, these grafts do not reproduce the natural mechanical properties of the aorta. Therefore, the aim of this project was to develop an innovative graft that additionally exhibits physiological aortic compliance. To achieve this result, multi-layered tubular aortic grafts were created by electrospinning of a thermoplastic polyurethane. To reduce permeability, a gelatin-coating was added. Three groups (G1–3; n = 5) with varying layer designs were evaluated regarding the main mechanical properties of vascular grafts such as suture retention strength, permeability and static and dynamic compliance. G3, which combined electrospinning with a stable silicone-coated inlay was chosen for the fabrication of medical grade thermoplastic polyurethane grafts (Gm; n = 6). Dynamic compliance values of 19.68 ± 11.5%/100 mmHg (50–90 mmHg), 15.18 ± 8.7%/100 mmHg (80–120 mmHg) and 14.56 ± 7.4%/100 mmHg (110–150 mmHg) were achieved. The compliance was higher than for Dacron and ePTFE grafts and comparable to the normal sized ascending aorta of around 16%/100 mmHg in a healthy human and porcine aortic compliance of 14.3%/100 mmHg. Static compliance was successfully tested up to 350 mmHg. No significant changes in graft diameter or delaminations of the graft layers were detected after compliance testing. Therefore, by combining electrospinning with a durable inlay, both elasticity and recoverability are obtained, resulting in a promising alternative to the gold-standard in open-surgical treatment of thoracic aortic pathologies.

27 November 2024 in ASAIO Journal
Verified
Journal Article
Closed access
CHChristopher Herz
Christopher Herz
MGMaximilian Grab
Maximilian Grab
CMChristoph S Mueller
Christoph S Mueller
MHMaja Hanuna
Maja Hanuna
Christine KamlaChristine Kamla
Christine Kamla
LGLinda Grefen
Linda Grefen
Continuous-flow left ventricular assist devices have become an important treatment option for patients with advanced heart failure. However, adverse hemodynamic effects as consequence of an altered blood flow within the aorta and the aortic root remain a topic of concern. In this work, we investigated the influence of the outflow graft orientation on the hemodynamic profile and flow parameters within the thoracic aorta. Aortic models with different outflow graft orientations were designed and three-dimensional (3D) printed to mimic common implantation configurations and were integrated into a pulsatile mock circulatory flow loop. Assist device function was achieved using a rotary pump, replicating nonpulsatile, continuous support flows of 1–5 L/min. Flow velocity, wall shear stress, and pressure gradients were investigated for each configuration using sonography and four-dimensional (4D) flow magnetic resonance imaging. Mean wall shear stresses measured in 4D flow software were lowest for a graft inclination angle of 45°. Streamline visualization revealed areas of nonuniform, retrograde, and vortex flow in all models but most prominent for the aortic model with an outflow graft inclination of 60°. The insights gained from this research may aid in understanding clinical outcomes following assist device implantation and long-term mechanical circulatory support.

Verified
Journal Article
Open access
PDF file
CRCaroline Radner
Caroline Radner
SSSandra Schmid
Sandra Schmid
MSMoritz Alexander Sunderdiek
Moritz Alexander Sunderdiek
YSYelyzaveta Sitnikova
Yelyzaveta Sitnikova
CHClara Johanna Hellmich
Clara Johanna Hellmich
JBJoscha Buech
Joscha Buech
Ascending thoracic aortic aneurysm (ATAA) pathogenesis varies with aortic valve morphology, yet regional heterogeneity between inner curvature (IC) and outer curvature (OC) remains incompletely characterized. We hypothesized that regional differences between the outer and inner curvature of the ascending aorta are valve-morphology dependent and reflect distinct remodeling mechanisms in bicuspid versus tricuspid aortic valve-associated aortopathy. Ascending aortic tissue from 155 patients (69 tricuspid aortic valve [TAV], 68 bicuspid aortic valve [BAV], 18 non-aneurysmal heart transplantation [HTx] controls) underwent uniaxial tensile testing (n = 66), histological analysis, hydroxyproline assay, and reverse transcription quantitative PCR (RT-qPCR) for collagen (COL1A1, COL3A1, COL4A1, COL5A1, COL11A1) and elastin (ELN) genes. The OC was thinner than the IC in both TAV and BAV (p < 0.001), with no regional differences in HTx. TAV demonstrated increased OC stiffness (E-modulus 0.60 ± 0.31 vs. 0.43 ± 0.24 MPa, p = 0.004) with reduced failure strain (p = 0.013). BAV showed preserved stiffness but reduced OC extensibility (ε_max 56.5 ± 15.1% vs. 72.4 ± 21.7%, p < 0.001). BAV exhibited elevated OC collagen content (hydroxyproline OC/IC ratio 1.42, p = 0.048), whereas TAV showed reduced OC elastin area (p < 0.01). All collagen genes were upregulated at the OC in both TAV (all p < 0.001) and BAV (all p < 0.05), with COL11A1 showing the highest fold change (3.4-fold in TAV). ELN was reduced at the OC in TAV (p < 0.001) but unchanged in BAV. ATAAs exhibit distinct valve-dependent regional heterogeneities. The discordance between collagen gene expression and protein content suggests valve-specific differences in collagen regulation. These findings support distinct pathomechanisms and highlight the limitations of diameter-based risk stratification, motivating further investigation of regional wall assessment as a complement to current size criteria for surgical decision-making.