3 November 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
BFBishuang Fan
Bishuang Fan
QLQikai Li
Qikai Li
WWWen Wang
Wen Wang
GYGanzhou Yao
Ganzhou Yao
HMHaihang Ma
Haihang Ma
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Droop control strategy is widely used to control parallel inverters in a microgrid. However, due to the mismatched line impedance, the traditional droop control strategy is difficult to evenly share the reactive power and restrain the circulating current among multiple parallel inverters. In this article, an adaptive virtual impedance-based droop control strategy without communications is proposed to solve the reactive power sharing problem caused by the difference of line impedance. The reactive power output and voltage of each distribution generator are introduced into the adaptive virtual impedance controller to achieve a tradeoff between reactive power sharing accuracy and voltage drop. Small-signal stability analysis of the inverters equipped with the proposed controller is conducted to determine the optimal control parameters. Simulation and experimental results demonstrate the effectiveness of the proposed droop control strategy.

16 January 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WWWen Wang
Wen Wang
XZXiangjun Zeng
Xiangjun Zeng
LYLingjie Yan
Lingjie Yan
XXXianyong Xu
Xianyong Xu
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Traditional ground-fault arc suppression devices mainly deal with capacitive component of ground current and have weak effect on the active and harmonic ones, which limits the arc suppression performance. The capacitive-current detection needed in them suffers from low accuracy and robustness. The commonly used large-capacity reactive component may bring about overvoltage because of possible resonance with the distributed phase-to-ground capacitance. To solve these problems, an active ground-fault arc suppression device is presented. It employs a topology based on a single-phase inverter to inject current into the neutral without any large-capacity reactors, and, thus, avoids the aforementioned overvoltage. It compensates all the active, reactive, and harmonic components of the ground current to reliably extinguish the ground-fault arcs. A dual-loop voltage control method is proposed to realize arc suppression without capacitive-current detection. Its time-based feature also brings the benefit of fast response on ground-fault arc suppression. The principle of full current compensation is analyzed, together with the controller design method of the proposed device. Experiment on a prototype was carried out to validate the effectiveness of the device.

21 September 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WWWen Wang
Wen Wang
LYLingjie Yan
Lingjie Yan
XZXiangjun Zeng
Xiangjun Zeng
BFBishuang Fan
Bishuang Fan
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Neutral-to-ground overvoltage may occur in noneffectively grounded power systems because of the distributed parameters asymmetry and resonance between Petersen coil and distributed capacitances. Thus, the constraint of neutral-to-ground voltage is critical for the safety of distribution networks. In this paper, an active grounding system based on a single-phase inverter and its control parameter design method is proposed to achieve this objective. Relationship between its output current and neutral-to-ground voltage is derived to explain the principle of neutral-to-ground voltage compensation. Then, a practical current detection method is proposed to specify the reference of compensated current. A current control method consisting of proportional resonant and proportional integral (PI) with capacitive current feedback is then proposed to guarantee sufficient output current accuracy and stability margin subjecting to large range of load change. The PI method is taken as the comparative method and the performances of both control methods are presented in detail. Experimental results prove the effectiveness and novelty of the proposed grounding system and control method.

1 January 2013 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
WWWen Wang
Wen Wang
ALAn Luo
An Luo
XXXianyong Xu
Xianyong Xu
LFLu Fang
Lu Fang
TCThuyen Minh Chau
Thuyen Minh Chau
ZLZhou Li
Zhou Li
A space vector pulse‐width modulation (SVPWM) algorithm and a DC‐side voltage control strategy for three‐phase four‐switch shunt active power filters are proposed. The basic principle of three‐phase four‐switch inverters to output three‐phase balanced voltages is investigated in detail. Based on an advanced coordinate transformation, the proposed algorithm ensures basic voltage vectors to be right on the coordinate axes of αβ ‐coordinate system, which has the advantages of less computation and higher accuracy than the traditional. It synthesises zero vectors by equalising the duration time of two basic voltage vectors, which are equivalent in amplitude and opposite in phase, to simplify control logic and decrease harmonics of output voltages. To stabilise the DC bus voltage and balance the DC‐side capacitor voltages, a DC‐side voltage control strategy is presented. The former objective is obtained by controlling the active partition of the output currents, and the latter one by adapting the direct partition of phase C output current. An overall control method combining the proposed SVPWM algorithm with the DC‐side voltage control strategy is presented. Experimental results have shown the validity and feasibility of the proposed algorithm and strategy.

14 January 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
BFBishuang Fan
Bishuang Fan
GYGanzhou Yao
Ganzhou Yao
WWWen Wang
Wen Wang
XZXiangjun Zeng
Xiangjun Zeng
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
CZChao Zhuo
Chao Zhuo
A single line-to-ground (SLG) fault may lead to a more severe line-to-line fault and power supply interruption if the ground-fault current exceeds a certain value. Arc suppression device (ASD) is a good solution to eliminate the ground-fault current. A novel hybrid ASD is proposed in this article, which consists of a passive device and an active one. The passive device utilizes multiterminal breakers and an isolation transformer to couple a secondary voltage of a zig-zag grounding transformer to the neutral point to compensate the majority of the ground-fault current. The active device uses a single-phase voltage source inverter to eliminate the residual fault current due to the leakage inductance of the zig-zag grounding transformer in the passive device. A dual-loop voltage and current control method for the active device is designed for the accurate residual current compensation. Results of simulation and prototype experiment validate the effectiveness of the proposed hybrid ASD. The proposed hybrid ASD does not need to detect distributed line-to-ground parameters, and it has lower cost, less control complexity, higher reliability, and better performance, compared to other ASDs.

23 June 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
WWWen Wang
Wen Wang
XGXiong Gao
Xiong Gao
BFBishuang Fan
Bishuang Fan
XZXiangjun Zeng
Xiangjun Zeng
GYGanzhou Yao
Ganzhou Yao
Accurate faulty phase detection under single-line-to-ground (SLG) fault is the basis of the emerging voltage-based fault arc suppression technology. Most conventional faulty phase recognition criteria assume the distributed line-to-ground parameters are symmetrical, therefore suffering invalidity in actual distribution networks especially under high-resistance ground-fault conditions. This paper firstly analyzes the magnitude and phase angle variation models of the phase-to-ground voltages before and after the SLG fault. Considering the asymmetrical distributed parameters and the line impedance, the specific phase-to-ground voltage variation rules corresponding to SLG fault on each phase are then discussed. Based on the voltage variation rules, a robust and practical method for faulty phase identification is proposed, which does not need the distributed parameters. Finally, the correctness of the variation rules and the availability of the proposed method is verified by simulation. Comparative study shows the proposed method has better accuracy and applicability with the conventional methods when the asymmetry and ground-fault resistance are high.