Droop control strategy is widely used to control parallel inverters in a microgrid. However, due to the mismatched line impedance, the traditional droop control strategy is difficult to evenly share the reactive power and restrain the circulating current among multiple parallel inverters. In this article, an adaptive virtual impedance-based droop control strategy without communications is proposed to solve the reactive power sharing problem caused by the difference of line impedance. The reactive power output and voltage of each distribution generator are introduced into the adaptive virtual impedance controller to achieve a tradeoff between reactive power sharing accuracy and voltage drop. Small-signal stability analysis of the inverters equipped with the proposed controller is conducted to determine the optimal control parameters. Simulation and experimental results demonstrate the effectiveness of the proposed droop control strategy.
14 January 2021 in IEEE Transactions on Industrial Electronics
A single line-to-ground (SLG) fault may lead to a more severe line-to-line fault and power supply interruption if the ground-fault current exceeds a certain value. Arc suppression device (ASD) is a good solution to eliminate the ground-fault current. A novel hybrid ASD is proposed in this article, which consists of a passive device and an active one. The passive device utilizes multiterminal breakers and an isolation transformer to couple a secondary voltage of a zig-zag grounding transformer to the neutral point to compensate the majority of the ground-fault current. The active device uses a single-phase voltage source inverter to eliminate the residual fault current due to the leakage inductance of the zig-zag grounding transformer in the passive device. A dual-loop voltage and current control method for the active device is designed for the accurate residual current compensation. Results of simulation and prototype experiment validate the effectiveness of the proposed hybrid ASD. The proposed hybrid ASD does not need to detect distributed line-to-ground parameters, and it has lower cost, less control complexity, higher reliability, and better performance, compared to other ASDs.
23 June 2021 in IEEE Transactions on Power Delivery
Accurate faulty phase detection under single-line-to-ground (SLG) fault is the basis of the emerging voltage-based fault arc suppression technology. Most conventional faulty phase recognition criteria assume the distributed line-to-ground parameters are symmetrical, therefore suffering invalidity in actual distribution networks especially under high-resistance ground-fault conditions. This paper firstly analyzes the magnitude and phase angle variation models of the phase-to-ground voltages before and after the SLG fault. Considering the asymmetrical distributed parameters and the line impedance, the specific phase-to-ground voltage variation rules corresponding to SLG fault on each phase are then discussed. Based on the voltage variation rules, a robust and practical method for faulty phase identification is proposed, which does not need the distributed parameters. Finally, the correctness of the variation rules and the availability of the proposed method is verified by simulation. Comparative study shows the proposed method has better accuracy and applicability with the conventional methods when the asymmetry and ground-fault resistance are high.
Single-line-to-ground (SLG) fault arcs cause the intermittent over-voltages, leading to short circuits within large-scale area. In this paper, a flexible arc suppression device is proposed, which adopts a zigzag grounding transformer, multi-terminal breakers and an isolation transformer to regulate zero-sequence voltage. Principle of zero-sequence voltage regulation (ZVR) and arc suppression method is presented. By carefully choosing the secondary side voltages of grounding transformer as the input of isolation transformer, the zero-sequence voltage is nearly constrained to the opposite of faulty phase supply voltage, and the ground-fault current is limited to a very small value. This device has high adaptability for low-resistance ground fault as it doesn't adopt any electronic apparatus. A 10kV prototype was established and multiple fault conditions were experimented to verify the effectiveness of the proposed ZVR device and its arc suppression principle.
In the neutral ungrounded distribution network, the removal of permanent single-line-to-ground (SLG) fault easily leads to saturation of the electromagnetic voltage transformers (PT), which may cause ferroresonance overvoltage and PT failure. This paper analyzes the zero-sequence voltage after the removal of the SLG fault and reveals the mechanism of ferroresonance excited by the removal of the SLG fault. Then, the total power and transient energy of the zero-sequence circuit under the SLG fault are analyzed. It is deduced that the energy reaches the minimum value at the zero-cross point (ZCP) of the neutral voltage. Based on this, a permanent SLG fault removal method to avoid ferroresonance is proposed, which uses the ZCP point as the fault removal instant. Simulations in ATP-EMTP show that the proposed method can effectively avoid ferroresonance on subharmonic mode. It can also enhance the ferroresonance suppression performance of the ferroresonance suppression resistor in the fundamental-frequency and high-frequency conditions.
30 December 2025 in IEEE Transactions on Power Delivery
Due to tree growth and wind-induced disturbances, tree-contact arc grounding faults (TAGFs) occur frequently in distribution networks. In the initial stage of the fault, the fault signal is weak and can frequently be undetected by protective devices. Therefore, a multiphysics simulation model coupling arc plasma behavior with distribution system response is developed based on magnetohydrodynamic (MHD) theory. The influences of tree species, moisture content, and branch swing velocity on arc temperature, morphology, and fault current amplitude are analyzed. A time-domain energy balance analysis is conducted to reveal the mechanisms underlying current zero-crossing behavior. Experimental results validate the model’s ability to accurately reproduce key TAGF features, including high fault impedance, arc temperature fluctuations, and neutral-point voltage oscillations. The findings provide a physically interpretable foundation for early detection and suppression of TAGFs in ungrounded distribution systems.