The origin of agricultural products is crucial to their quality and safety. This study explored the differences in chemical composition and structure of rice from different origins using fluorescence detection technology. These differences are mainly affected by climate, environment, geology and other factors. By identifying the fluorescence characteristic absorption peaks of the same rice seed varieties from different origins, and comparing them with known or standard samples, this study aims to authenticate rice, protect brands, and achieve traceability. The study selected the same variety of rice seed planted in different regions of Jilin Province in the same year as samples. Fluorescence spectroscopy was used to collect spectral data, which was preprocessed by normalization, smoothing, and wavelet transformation to remove noise, scattering, and burrs. The processed spectral data was used as input for the long short-term memory (LSTM) model. The study focused on the processing and analysis of rice spectra based on NZ-WT-processed data. To simplify the model, uninformative variable elimination (UVE) and successive projections algorithm (SPA) were used to screen the best wavelengths. These wavelengths were used as input for the support vector machine (SVM) prediction model to achieve efficient and accurate predictions. Within the fluorescence spectral range of 475–525 nm and 665–690 nm, absorption peaks of nicotinamide adenine dinucleotide (NADPH), riboflavin (B2), starch, and protein were observed. The origin tracing prediction model established using SVM exhibited stable performance with a classification accuracy of up to 99.5%.The experiment demonstrated that fluorescence spectroscopy technology has high discrimination accuracy in tracing the origin of rice, providing a new method for rapid identification of rice origin.
Lignin is one of the building blocks of plant cell walls, and the study of the spectral characterization of its cleavage process can help to monitor the production and reuse of straw after decay. In this paper, four theoretical model structures of lignin formed by lignin G monomers and connected by β-O-4 bonding type were optimized and calculated based on the density functional theory using the B3LYP/3-21g and B3LYP/6-311g basis sets. The results showed that the theoretical infrared spectra of lignin increased sequentially in the absorption peaks of 1500 cm−1 blue shift and 2932 cm−1 and 1200 cm−1 red shift, while the latter three theoretical models showed new infrared absorption peaks of 716 cm−1 and 823 cm−1 due to the presence of the β-O-4 structure, which is of great value for the theoretical spectral study of organic macromolecules and also provides data support for the spectral change in lignin in the degradation of graminaceous plants.
The origin of agricultural products significantly influences their quality and safety. Fluorescence spectroscopy was used to analyse Japonica rice 830, grown in different areas of Jilin Province, by examining rice seed, brown rice, and rice flour from 12 origins. Fluorescence spectra were pre-processed through normalisation and smoothing to remove noise. These processed spectra were input into decision trees, support vector machines (SVMs), K-nearest neighbour (KNN), and neural network models for classification. The analysis revealed that the combined four models achieved an average classification accuracy of 98.05% with a computation time of 180 s, while the reduced-scale models improved accuracy to 98.36% and reduced computation time to 11.25 s. Additionally, prediction models using standard rice starch content values across different states achieved R² values over 0.8. This method provides a rapid, precise approach for assessing rice quality and origin, demonstrating significant potential for application in rice analysis.
To ensure consumers can purchase high-quality rice, accurate identification of rice varieties is particularly important. Methods: This article conducts research based on machine learning algorithms from the perspectives of image, spectrum, and spectrogram fusion. Six types of hyperspectral image data of rice were preprocessed using convolutional smoothing (SG) and multiple scatter correction (MSC). Texture information of the images was extracted using gray-level co-occurrence matrix. Spectra, texture, and spectrogram data were fused into a new matrix. Spectral, texture, and spectrogram fusion data were used as inputs for the model, and support vector machines (SVM), logistic regression (LR), and K-nearest neighbors (KNN) classification models were constructed and compared. Results: From the classification results, the spectrogram fusion classification performance was better than classification models using only spectra or texture. Conclusion: The research results showed that the accuracy of SVM and LR classification models exceeded 90%, and the LR model performed the best, effectively classifying rice varieties.
The storage time of rice determines its quality and nutritional value, and the longer the storage time, the greater the impact. In this study, different excitation wavelengths (405 nm, 365 nm, 310 nm) were used to detect the fluorescence spectrum of “Dongdao 12” brown rice. Support vector machine (SVM), K-nearest neighbor (KNN), and wide neural network (WNN) were used for modeling and analysis. Under the excitation of 310 nm, the accuracy of WNN classification is up to 99.2%. In order to reduce the scattering effect and other interference in the data, multiplicative scatter correction (MSC), standard normal variable (SNV), and Savitzky–Goray smoothing (SG) preprocessing methods were used. The results showed that SG + KNN classification achieved an accuracy of 99.3% under 310 nm excitation. In order to further improve the classification accuracy, the original spectrum and the preprocessed spectrum under different excitation light sources were fused. The classification accuracy of all methods was improved, and the original data fusion was combined with the WNN model to reach 100%. It shows that fluorescence spectroscopy has excellent potential in identifying rice storage years.
Accurate high-temperature field characterization is important for explosion diagnostics, laser–matter interaction, combustion monitoring, and related thermal processes. This work presents an integrated thermometry framework combining fiber-optic spectrometry with monochrome imaging. Its central contribution is not a new multispectral principle or optimization algorithm, but an integration-time-dependent radiometric calibration framework coupled with representative spectral-emissivity transfer under clearly stated applicability conditions. Its central element is a three-parameter radiometric calibration model in which camera integration time is explicitly included, so that radiance conversion can be performed across the experimentally calibrated integration-time range without repeating a separate fixed-exposure calibration for each setting. Multiwavelength spectral radiance is used to jointly retrieve temperature and a continuous, second-order polynomial emissivity function with a genetic algorithm serving as the global optimizer. The emissivity function obtained from a representative spectral sampling region is then transferred to the imaging model for pixelwise temperature inversion; this step assumes that the material and surface state are sufficiently uniform over the region to which the function is applied. The method is examined using steady-state tungsten–halogen-lamp measurements with nominal color temperatures of 2200–2800 K and a transient laser-heated 316L stainless-steel case. Agreement with a Wien-based estimate is used as an internal spectral-consistency check rather than as an independent traceable accuracy validation. In the transient case, the retrieved spectral-field-of-view temperature increased from 2311.9 to 2398.5 K over 50–60 s, and the reconstructed images reproduced the corresponding increase in the central high-temperature region. The present results demonstrate the feasibility of coupling integration-time-dependent calibration with measured spectral-emissivity transfer for two-dimensional temperature reconstruction, while the achievable absolute accuracy remains subject to detector linearity, emissivity-model validity, spatial emissivity uniformity, radiometric calibration, and independent reference validation.