Meng Zhao

Dr. Meng Zhao

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
MZMeng Zhao
Meng Zhao
MBMaoyong Bai
Maoyong Bai
ZWZhaojun Wu
Zhaojun Wu
SBShaodong Bai
Shaodong Bai
ZQZHENG QIU
ZHENG QIU
HCHongxing Cai
Hongxing Cai
Multispectral temperature measurement technology based on blackbody radiation theory has been widely applied in the field of non-contact temperature measurement. However, its applicability is limited by the single-point measurement mode. To address this limitation, this study developed a spectral fusion temperature measurement device and proposed a new method for reconstructing the two-dimensional temperature field of deflagration fireballs by fusing spectral and imaging data. The device adopts a CCD sensor and a fiber optic spectrometer placed in parallel with parallel optical axes. To ensure the accuracy of the CCD’s response characteristics at different distances, the photo-response non-uniformity (PRNU) calculation method was used for precision validation. In this study, spectral and imaging data of deflagration fireballs were obtained through experiments. Spectral data of consecutive frames at 189 ms, 192 ms, 195 ms, and 198 ms were extracted and analyzed, confirming that the temperature range at the four time points is 1050 K to 1800 K. The proposed method generates temperature elements with equal temperature intervals and their probabilities within the temperature range, and calculates the theoretical radiation spectrum of each element. Then, least squares optimization fitting is performed on the experimentally measured spectra to obtain the optimal probabilities of the temperature elements in the temperature field. By combining these optimal probabilities with CCD grayscale images, the 2D temperature distribution of the deflagration fireball was reconstructed. Results show that: the PRNU value of the device at a distance of 9 m is less than 2.2% through experimental verification; fused images of the temperature field spectra of four consecutive frames of the deflagration fireball were obtained using the proposed method. The average temperatures reconstructed by the proposed method at 189 ms, 192 ms, 195 ms, and 198 ms were 1382 K, 1373 K, 1366 K, and 1357 K, respectively, while the corresponding temperatures obtained by conventional spectral inversion were 1430 K, 1422 K, 1414 K, and 1406 K. The relative errors were 3.2%, 3.4%, 3.3%, and 3.4%, respectively, with an average relative error of approximately 3.3%.

20 July 2026 in Communications Chemistry
Verified
Journal Article
Open access
PDF file
KDKang Du
Kang Du
MZMeng Zhao
Meng Zhao
TWTingting Wang
Tingting Wang
GQGuannan Qu
Guannan Qu
HCHongxing Cai
Hongxing Cai
Diabetes mellitus affects approximately 589 million adults worldwide, underscoring the need for accurate and noninvasive glucose monitoring to reduce complications. Although Raman spectroscopy shows promise for noninvasive blood glucose detection due to its molecular specificity and minimal interference, its application has been limited by the oversimplification of glucose as an open-chain structure in solution and unresolved assignments of characteristic bands—particularly the widely used 1125 cm⁻¹ peak. In this study, we combine density functional theory simulations with experimental Raman spectroscopy to elucidate the vibrational origins of glucose bands across all physiologically relevant tautomers and derivatives, including α-D-Glucopyranose and β-D-Glucopyranose, α-D-Glucofuranose and β-D-Glucofuranose, the open-chain form, D-Glucose-monohydrate, and 1,5-Anhydroglucitol. We present the first comprehensive, assignment-validated Raman spectral atlas and vibrational assignment of accurate aqueous glucose structures, achieving unprecedented agreement between theory and experiment. Highly specific spectral markers are identified to distinguish pyranose and furanose rings, anomeric configurations, hydration states, and the bicyclic features of 1,5-Anhydroglucitol. These findings resolve decades-long controversies in glucose vibrational spectroscopy and provide essential reference standards to advance Raman-based noninvasive monitoring of short-term glycemic control and early glycation risk in diabetic patients.

28 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
MZMeng Zhao
Meng Zhao
CLChunyu Liu
Chunyu Liu
MBMaoyong Bai
Maoyong Bai
ZQZheng Qiu
Zheng Qiu
SBShaodong Bai
Shaodong Bai
HCHongxing Cai
Hongxing Cai
Accurate high-temperature field characterization is important for explosion diagnostics, laser–matter interaction, combustion monitoring, and related thermal processes. This work presents an integrated thermometry framework combining fiber-optic spectrometry with monochrome imaging. Its central contribution is not a new multispectral principle or optimization algorithm, but an integration-time-dependent radiometric calibration framework coupled with representative spectral-emissivity transfer under clearly stated applicability conditions. Its central element is a three-parameter radiometric calibration model in which camera integration time is explicitly included, so that radiance conversion can be performed across the experimentally calibrated integration-time range without repeating a separate fixed-exposure calibration for each setting. Multiwavelength spectral radiance is used to jointly retrieve temperature and a continuous, second-order polynomial emissivity function with a genetic algorithm serving as the global optimizer. The emissivity function obtained from a representative spectral sampling region is then transferred to the imaging model for pixelwise temperature inversion; this step assumes that the material and surface state are sufficiently uniform over the region to which the function is applied. The method is examined using steady-state tungsten–halogen-lamp measurements with nominal color temperatures of 2200–2800 K and a transient laser-heated 316L stainless-steel case. Agreement with a Wien-based estimate is used as an internal spectral-consistency check rather than as an independent traceable accuracy validation. In the transient case, the retrieved spectral-field-of-view temperature increased from 2311.9 to 2398.5 K over 50–60 s, and the reconstructed images reproduced the corresponding increase in the central high-temperature region. The present results demonstrate the feasibility of coupling integration-time-dependent calibration with measured spectral-emissivity transfer for two-dimensional temperature reconstruction, while the achievable absolute accuracy remains subject to detector linearity, emissivity-model validity, spatial emissivity uniformity, radiometric calibration, and independent reference validation.