Roland Zengerle

Dr. Roland Zengerle

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2010 in Chemical Society Reviews
Verified
Journal Article
Closed access
PDF file
DMDaniel Mark
Daniel Mark
SHStefan Haeberle
Stefan Haeberle
GRGünter Roth
Günter Roth
FSFelix von Stetten
Felix von Stetten
RZRoland Zengerle
Roland Zengerle
This critical review summarizes developments in microfluidic platforms that enable the miniaturization, integration, automation and parallelization of (bio-)chemical assays (see S. Haeberle and R. Zengerle, Lab Chip, 2007, 7, 1094–1110, for an earlier review). In contrast to isolated application-specific solutions, a microfluidic platform provides a set of fluidic unit operations, which are designed for easy combination within a well-defined fabrication technology. This allows the easy, fast, and cost-efficient implementation of different application-specific (bio-)chemical processes. In our review we focus on recent developments from the last decade (2000s). We start with a brief introduction into technical advances, major market segments and promising applications. We continue with a detailed characterization of different microfluidic platforms, comprising a short definition, the functional principle, microfluidic unit operations, application examples as well as strengths and limitations of every platform. The microfluidic platforms in focus are lateral flow tests, linear actuated devices, pressure driven laminar flow, microfluidic large scale integration, segmented flow microfluidics, centrifugal microfluidics, electrokinetics, electrowetting, surface acoustic waves, and dedicated systems for massively parallel analysis. This review concludes with the attempt to provide a selection scheme for microfluidic platforms which is based on their characteristics according to key requirements of different applications and market segments. Applied selection criteria comprise portability, costs of instrument and disposability, sample throughput, number of parameters per sample, reagent consumption, precision, diversity of microfluidic unit operations and the flexibility in programming different liquid handling protocols (295 references).

Verified
Journal Article
Open access
PDF file
AGAndre Gross
Andre Gross
JSJonas Schoendube
Jonas Schoendube
SZStefan Zimmermann
Stefan Zimmermann
MSMaximilian Steeb
Maximilian Steeb
RZRoland Zengerle
Roland Zengerle
PKPeter Koltay
Peter Koltay
The handling of single cells is of great importance in applications such as cell line development or single-cell analysis, e.g., for cancer research or for emerging diagnostic methods. This review provides an overview of technologies that are currently used or in development to isolate single cells for subsequent single-cell analysis. Data from a dedicated online market survey conducted to identify the most relevant technologies, presented here for the first time, shows that FACS (fluorescence activated cell sorting) respectively Flow cytometry (33% usage), laser microdissection (17%), manual cell picking (17%), random seeding/dilution (15%), and microfluidics/lab-on-a-chip devices (12%) are currently the most frequently used technologies. These most prominent technologies are described in detail and key performance factors are discussed. The survey data indicates a further increasing interest in single-cell isolation tools for the coming years. Additionally, a worldwide patent search was performed to screen for emerging technologies that might become relevant in the future. In total 179 patents were found, out of which 25 were evaluated by screening the title and abstract to be relevant to the field.

19 March 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MFMaximilian Focke
Maximilian Focke
DKDominique Kosse
Dominique Kosse
CMClaas Müller
Claas Müller
HRHolger Reinecke
Holger Reinecke
RZRoland Zengerle
Roland Zengerle
FSFelix von Stetten
Felix von Stetten
This critical review is motivated by an increasing interest of the microfluidics community in developing complete Lab-on-a-Chip solutions based on thin and flexible films (Lab-on-a-Foil). Those implementations benefit from a broad range of fabrication methods that are partly adopted from well-established macroscale processes or are completely new and promising. In addition, thin and flexible foils enable various features like low thermal resistance for efficient thermocycling or integration of easily deformable chambers paving the way for new means of on-chip reagent storage or fluid transport. From an economical perspective, Lab-on-a-Foil systems are characterised by low material consumption and often low-cost materials which are attractive for cost-effective high-volume fabrication of self-contained disposable chips. The first part of this review focuses on available materials, fabrication processes and approaches for integration of microfluidic functions including liquid control and transport as well as storage and release of reagents. In the second part, an analysis of the state of Lab-on-a-Foil applications is provided with a special focus on nucleic acid analysis, immunoassays, cell-based assays and home care testing. We conclude that the Lab-on-a-Foil approach is very versatile and significantly expands the toolbox for the development of Lab-on-a-Chip solutions.

7 July 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MFMaximilian Focke
Maximilian Focke
FSFabian Stumpf
Fabian Stumpf
BFBernd Faltin
Bernd Faltin
PRPatrick Reith
Patrick Reith
DBDylan Bamarni
Dylan Bamarni
FSFelix von Stetten
Felix von Stetten
We present a novel process flow enabling prototyping of microfluidic cartridges made out of polymer films. Its high performance is proven by implementation of a microfluidic genotyping assay testing 22 DNA samples including clinical isolates from patients infected by methicilin-resistant Staphylococcus aureus (MRSA). The microfluidic cartridges (disks) are fabricated by a novel process called microthermoforming by soft lithography (µTSL). Positive moulds are applied allowing for higher moulding precision and very easy demoulding when compared to conventional microthermoforming. High replication accuracies with geometric disk-to-disk variations of less than 1% are typical. We describe and characterise fabrication and application of microfluidic cartridges with wall thicknesses <188 µm thus enabling efficient thermocycling during real-time polymerase chain reaction (PCR). The microfluidic cartridges are designed for operation in a slightly modified commercial thermocycling instrument. This approach demonstrates new opportunities for both microfluidic developments and well-established laboratory instruments. The microfluidic protocol is controlled by centrifugal forces and divides the liquid sample parallely into independent aliquots of 9.8 µl (CV 3.4%, N = 32 wells). The genotyping assays are performed with pre-stored primers and probes for real-time PCR showing a limit of detection well below 10 copies of DNA per reaction well (N = 24 wells in 3 independent disks). The system was evaluated by 44 genotyping assays comprising 22 DNA samples plus duplicates in a total of 11 disks. The samples contained clinical samples of seven different genotypes of MRSA as well as positive and negative controls. The results are in excellent agreement with the reference in microtubes.

11 October 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MFMaximilian Focke
Maximilian Focke
FSFabian Stumpf
Fabian Stumpf
GRGünter Roth
Günter Roth
RZRoland Zengerle
Roland Zengerle
FSFelix von Stetten
Felix von Stetten
Pre-amplification is a basis for numerous polymerase chain reaction (PCR) protocols but bears severe contamination risks due to handling of high-copy DNA samples. Therefore we developed a self-contained centrifugal microfluidic system comprising pre-stored reagents; it enables pre-amplification of specific DNA sequences prior to automated aliquoting and real-time PCR in a modified commercial thermocycler.

1 January 2015 in Biomicrofluidics
Verified
Journal Article
Open access
PDF file
JSJ. Schoendube
J. Schoendube
DWD. Wright
D. Wright
RZRoland Zengerle
Roland Zengerle
PKP. Koltay
P. Koltay
Label-free isolation of single cells is essential for the growing field of single-cell analysis. Here, we present a device which prints single living cells encapsulated in free-flying picoliter droplets. It combines inkjet printing and impedance flow cytometry. Droplet volume can be controlled in the range of 500 pl–800 pl by piezo actuator displacement. Two sets of parallel facing electrodes in a 50 μm × 55 μm channel are applied to measure the presence and velocity of a single cell in real-time. Polystyrene beads with <5% variation in diameter generated signal variations of 12%–17% coefficients of variation. Single bead efficiency (i.e., printing events with single beads vs. total number of printing events) was 73% ± 11% at a throughput of approximately 9 events/min. Viability of printed HeLa cells and human primary fibroblasts was demonstrated by culturing cells for at least eight days.