Shanran Wang

Dr. Shanran Wang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
PLPin Li
Pin Li
MCMiaopeng Chen
Miaopeng Chen
TYTianle Yao
Tianle Yao
LWLong Wu
Long Wu
SWShanran Wang
Shanran Wang
JYJia Yin
Jia Yin
Tea, a worldwide prevalent beverage, is continually contaminated by pesticide residues and heavy metals, presenting considerable health concerns to consumers. Nonetheless, effective monitoring is limited by conventional detection techniques—such as gas chromatography (GC) and inductively coupled plasma mass spectrometry (ICP-MS)—which, despite their high precision, necessitate intricate pretreatment, incur substantial operational expenses, and are inadequate for swift on-site analysis. Biosensors have emerged as a viable option, addressing this gap with their exceptional sensitivity, rapid response, and ease of operation.This review rigorously evaluates recent advancements in biosensing technologies for the detection of pesticide residues and heavy metals in tea, emphasizing the mechanisms, analytical performance, and practical applicability of prominent platforms such as fluorescence, surface-enhanced Raman scattering (SERS), surface plasmon resonance (SPR), colorimetric, and electrochemical biosensors. Electrochemical and fluorescent biosensors provide the highest promise for portable, on-site use owing to their enhanced sensitivity, cost-effectiveness, and flexibility to intricate tea matrices. The paper further emphasizes upcoming techniques such multi-component detection, microfluidic integration, and AI-enhanced data processing. Biosensors provide significant potential to revolutionize tea safety monitoring, with future advancements dependent on the synergistic incorporation of sophisticated nanomaterials, intelligent microdevices, and real-time analytics across the whole “tea garden-to-cup” supply chain.

2 July 2024 in Buildings
Verified
Journal Article
Open access
PDF file
SWShanran Wang
Shanran Wang
XCXiaodong Cao
Xiaodong Cao
丹苗丹 苗
丹 苗
Liping PangLiping Pang
Liping Pang
Jiayu LiJiayu Li
Jiayu Li
The civil aircraft cabin is enclosed and highly occupied, making it susceptible to a decline in indoor environmental quality. The environmental quality of civil aircraft cabins not only depends on objective factors such as temperature, relative humidity, and the presence of air pollutants such as carbon dioxide (CO2), carbon monoxide (CO), ozone (O3), particle matter (PM), and volatile organic compounds (VOCs) but also the subjective factors pertaining to the perceptions and health symptoms of passengers and crew. However, few studies have thoroughly examined the air quality and thermal comfort parameters that are measured during in-flight testing in airplane cabins, as well as the passengers’ subjective perceptions. In order to evaluate the in-flight thermal comfort and air quality status, this study conducted a review of the recent literature to compile data on primary categories, standard limits, and distribution ranges of in-flight environmental factors within civil aircraft cabins. Following a search procedure outlined in this paper, 54 papers were selected for inclusion. Utilizing the Monte Carlo method, the Predicted Mean Vote (PMV) distributions under different exercise intensities and clothing thermal resistance were measured with the in-cabin temperature and humidity from in-flight tests. Recommendations based on first-hand data were made to maintain the relative humidity in the cabin below 40%, ensure wind speed remains within the range of 0–1 m/s, and regulate the temperature between 25–27 °C (for summer) and 22–27 °C (for winter). The current estimated cabin air supply rate generally complies with the requirements of international standards. Additionally, potential carcinogenic and non-carcinogenic risks associated with formaldehyde, benzene, tetrachloroethylene, and naphthalene were calculated. The sorted data of in-flight tests and the evaluation of the subjective perception of the occupants provide an evaluation of current cabin thermal comfort and air quality status, which can serve as a reference for optimizing indoor environmental quality in future generations of civil aircraft cabins.

29 September 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
SWShanran Wang
Shanran Wang
Liping PangLiping Pang
Liping Pang
PLPei Li
Pei Li
TJTingting Jiao
Tingting Jiao
XWXiyue Wang
Xiyue Wang
HYHao Yin
Hao Yin
In the context of team collaborative tasks, continuous operational capability represents a crucial indicator of operational efficiency and a pivotal area of current research. A reduction in the continuous operational capability of team members will inevitably result in an increase in the error rate, which will prevent the completion of the task. In certain circumstances, this may even result in more severe consequences. To guarantee that team members possess optimal operational capabilities, it is imperative to conduct research on continuous operational capability prediction. This paper presents a Bayesian network-based continuous operational capability prediction model for team collaborative tasks. The model is developed based on the causal relationship of the continuous operational capability evolution, and through the improvement on the Bayesian network so that it can be suitable for individual personnel. The experimental verification demonstrates that the model produces accurate results and can be employed to predict the continuous operational capability and its changing trend.

25 August 2025 in Processes
Verified
Journal Article
Open access
PDF file
PLPin Li
Pin Li
YCYongxing Chen
Yongxing Chen
SWShanran Wang
Shanran Wang
YMYuanjin Ma
Yuanjin Ma
The underwater lavatories aboard ships are compact and suffer from inadequate ventilation, thereby increasing the likelihood of infection and odor issues. The crew will endure discomfort from the poor air quality within the lavatories, especially following prolonged travel. This study establishes a three-dimensional numerical model of an underwater lavatory unit, employing computational fluid dynamics (CFD) to assess ventilation performance and contaminant distributions. The concentration of odor gas and the fate of particles within the lavatory were evaluated for a duration of 3 min subsequent to flushing, considering two scenarios: occupants using either the toilet or the urinal. Additionally, the exhaust air volume and the layouts of the lavatory vents were optimized. The results indicate that the individual using the toilet has a lower concentration of ammonia inhalation, and both scenarios remain unaffected by odors within 60 s after flushing. In contrast to the scenario of using the toilet, the case of using the urinal poses notably fewer risks of human contact, with 65.7% of the deposited particles residing on the urinal surfaces and a mere 8.9% adhering to the manikin surfaces. Enhancing the exhaust air volume can facilitate odor removal in the urinal scenario while slightly improving odor control in the case of using the toilet. An airflow rate of 250 m3/h resulted in a 40% increase in particle deposition within the urinal and a roughly 70% decrease on the manikin during the toileting scenario. The existing ship lavatory ventilation is insufficient to manage the risk of aerosol exposure and sense of smell in the breathing zone of standing crew. The air quality within a lavatory can be significantly improved by employing upper air-supply and lower air-exhaust ventilation.

28 September 2026 in Buildings
Verified
Journal Article
Open access
PDF file
HTHaijun Tan
Haijun Tan
SWShanran Wang
Shanran Wang
WLWenli Liu
Wenli Liu
PLPin Li
Pin Li
Maintaining a stable thermal environment is essential for ensuring data center thermal safety and reliable operation. However, existing studies lack a systematic synthesis of thermal environment measurement, modeling approaches, and their contributions to energy-efficient cooling. This review systematically analyzes 77 studies published since 2010 on experimental measurement, CFD simulation, and predictive modeling of data center thermal environments. The review identifies representative measurement strategies at rack and room scales, analyzes factors affecting CFD reliability, and evaluates the applicability of predictive models based on experimental and simulation data. Most experimental studies focus on temperature and airflow, while only about 30.7% of the 39 experimental studies include power measurements, limiting quantitative evidence linking thermal optimization with energy performance. Among the 58 CFD studies, Fluent was used in 41.4% of cases, while 70.6% of the 17 predictive-model studies relied on CFD data for model training. CFD reliability remained sensitive to boundary conditions, model simplifications, and validation strategies. Predictive modeling was dominated by machine learning and deep learning, while reduced-order and surrogate models were also applied, enabling rapid temperature-field and thermal-risk assessment but remaining constrained by training data quality and operating condition coverage. These findings establish an integrated framework in which measurements provide empirical benchmarks, CFD extends spatial and operational understanding, and predictive models enable rapid assessment for thermal environment management and cooling energy optimization.