Abdoelrahman Hassan A. B.

Abdoelrahman Hassan A. B.


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2025 in Tomography
Verified
Journal Article
Open access
PDF file
Zuhal Yassin HamdZuhal Yassin Hamd
Zuhal Yassin Hamd
HAHuda Ibrahim Al-Mohammed
Huda Ibrahim Al-Mohammed
EMElbagir Hamza Manssor
Elbagir Hamza Manssor
ABAbdoelrahman Hassan A. B.
Abdoelrahman Hassan A. B.
AGAwadia Gareeballah
Awadia Gareeballah
Background: As a diagnostic radiology procedure, computed tomography (CT) contributes to patient radiation exposure; hence, it deserves special consideration. The use of diagnostic reference levels (DRLs) is an efficient way to optimize patient radiation dosage. The computed tomography dose index volume (CTDIv) and the dose-length product (DLP) help to measure DRLs. Methods: A retrospective analysis was conducted on 106 patients (43.9% male, 56.1% female; mean age of 48.18 years) who underwent computed tomography chest, abdomen, and pelvis (CT CAP) scans using a Toshiba Aquilion Prime 160-slice CT scanner. Data included patient demographics, CT parameters (mA, tube rotation time, pitch, slice thickness, and slice count), and dose indices: dose length product (DLP), computed tomography dose index volume (CTDIvol), and effective dose. Cancer risks were calculated based on effective dose, patient demographics, and scan parameters. Results: This study demonstrated that the mean values for DLP, CTDIvol, and effective dose were 1719.64 ± 488.45 mGy·cm, 25.97 ± 6.96 mGy, and 27.5 ± 7.82 mSv, respectively. Cancer risk estimates ranged from 0.048% to 1.58%, with higher risks observed for females, younger patients. Significant correlations were found between dose indices and technical parameters, including pitch, kVp, tube rotation time, and slice thickness (p < 0.005). Conclusions: The mean values for DLP, CTDIvol, and effective dose for abdominopelvic scans were higher than those found in previous studies, with significant correlation of weight on these values. Optimizing CT protocols and establishing DRLs tailored to clinical indications are critical for minimizing radiation exposure and enhancing patient safety.

16 May 2021 in Eastern Journal of Medical Sciences
Verified
Journal Article
Open access
PDF file
GSGhada Abker Edam Sakin
Ghada Abker Edam Sakin
MOMohammed Ali Omer
Mohammed Ali Omer
MGMohamed Elfadil Mohamed Gar-Elnabi
Mohamed Elfadil Mohamed Gar-Elnabi
ABAbdoelrahman Hassan A. B.
Abdoelrahman Hassan A. B.
BEBadria Awad Elamin
Badria Awad Elamin
Background: Nuclear medicine (NM) technology is as indispensable field, is being widely used in research as well for diagnostic/staging purposes. However, it is also associated with potential hazards of radiation especially among radiation practitioners. Objective: The objective of the study was to determine the effects of NM exposure doses of bone scintigraphy in red blood cells and to propose a recent technology to be incorporated in NM and radiology technologies. Materials and Methods: A retrospective study was carried out among 75 patients who underwent bone scintigraphy between 2014 and 2018. A blood sample of these patients was characterized using transmitted light microscope and obtained data were analyzed using SPSS. Results: There was a decrease in the RBCs% and hemoglobin (HGb) count with the increment of interval time of bone scintigraphy (p=0.3). The average applied radioactive (Methylene Di-phosphate/Technetium-99m) dose of 15±2.9 mCi reduces RBCs and HGb count insignificantly by 3.56% and 3.1%, respectively. With an increased dose of 20±5.8 mCi and after interval time of bone scintigraphy, the histological changes in RBCs such as loss of biconcavity, increased diameter (10±0.4 ?m), developed spikes (anisocytosis and poikilocytosis) were observed. Conclusion: The proposed robotic intelligent system can be utilized partially while performing NM and other radiological examinations under supervision of specialists to prevent stochastic and non-stochastic effects among radiation practitioners.

18 April 2024 in Radiology Case Reports
Verified
Journal Article
Open access
ABAbdoelrahman Hassan A. B.
Abdoelrahman Hassan A. B.
Zuhal Yassin HamdZuhal Yassin Hamd
Zuhal Yassin Hamd
AAAmal I. Alorainy
Amal I. Alorainy
ABAuis Bashir
Auis Bashir
HEHassan Ahmed Elfaki
Hassan Ahmed Elfaki
ASAbdelmoneim Sulieman
Abdelmoneim Sulieman
Vein of Galen malformation (VGM) is a rare congenital, uncommon intracerebral vascular anomaly rarely complicated with the development of brain abscess as secondary to primary infection or after endovascular treatment. We report a very rare finding of a vein of Galen aneurysm associated with a large brain abscess at the time of diagnosis. A 12-year-old boy with a high-grade fever, severe headache, and recurrent episodes of convulsions came into the radiology department of Kassala Advanced Diagnostic Center. On a Siemens 16-slice scanner, brain non-contrast enhanced computed tomography (NECT) and contrast enhanced CT (CECT) was used to determine the source of the acute headache and convulsions which revealed a right frontal peripherally enhancing cystic lesion measuring 5.7 × 4.7 × 5.3 cm2 surrounded by massive vasogenic edema causing mass effect with midline shift to the left side by 1.5 cm suggestive of brain abscess. There is evidence of another avidly enhancing lesion seen within the third ventricle continuous with a straight sinus surrounded by extensive vascular loops consistent with an aneurysm of the vein of Galen, it was causing compression of the cerebral aqueduct with upstream mild hydrocephalus with dilated both lateral ventricles. Late presentation, diagnosis, and treatment also lead to an increase in the morbidities and mortalities of such case conditions. Urgent intervention should be considered for better outcomes.