Objectives: Diagnostic reference levels (DRLs) are crucial tools for optimizing radiation exposure during different radiological examinations. This study aimed to establish preliminary DRLs for commonly performed computed tomographic angiography (CTA) examinations in Saudi Arabia. Methods: Data for three types of CTA examinations (cerebral, pulmonary, and lower-extremity) were collected from six medical cities across Saudi Arabia. Data sets related to 723 CTAs with a mean patient weight of 75 kg were analysed in detail. The DRL values were determined based on the 75th, median, and 25th CT dose index volume (CTDIvol) and dose length product (DLP) values. Results: The established DRLs were 1221 mGy cm for cerebral CTAs, 475 mGy cm for pulmonary CTAs, and 1040 mGy cm for lower-extremity CTAs. These values were comparable to those reported in other studies. Conclusions: This study provides preliminary DRLs for three common CTA procedures in Saudi Arabia. The widespread implementation of a low kVp and a high level of image reconstruction (IR) presents an opportunity for further dose reduction. These findings can serve as a foundation for future nationwide DRL surveys and the optimization of CTA imaging protocols in Saudi Arabia.

3 June 2025 in Tomography
Verified
Journal Article
Open access
PDF file
Zuhal Yassin HamdZuhal Yassin Hamd
Zuhal Yassin Hamd
HAHuda Ibrahim Al-Mohammed
Huda Ibrahim Al-Mohammed
EMElbagir Hamza Manssor
Elbagir Hamza Manssor
ABAbdoelrahman Hassan A. B.
Abdoelrahman Hassan A. B.
AGAwadia Gareeballah
Awadia Gareeballah
Background: As a diagnostic radiology procedure, computed tomography (CT) contributes to patient radiation exposure; hence, it deserves special consideration. The use of diagnostic reference levels (DRLs) is an efficient way to optimize patient radiation dosage. The computed tomography dose index volume (CTDIv) and the dose-length product (DLP) help to measure DRLs. Methods: A retrospective analysis was conducted on 106 patients (43.9% male, 56.1% female; mean age of 48.18 years) who underwent computed tomography chest, abdomen, and pelvis (CT CAP) scans using a Toshiba Aquilion Prime 160-slice CT scanner. Data included patient demographics, CT parameters (mA, tube rotation time, pitch, slice thickness, and slice count), and dose indices: dose length product (DLP), computed tomography dose index volume (CTDIvol), and effective dose. Cancer risks were calculated based on effective dose, patient demographics, and scan parameters. Results: This study demonstrated that the mean values for DLP, CTDIvol, and effective dose were 1719.64 ± 488.45 mGy·cm, 25.97 ± 6.96 mGy, and 27.5 ± 7.82 mSv, respectively. Cancer risk estimates ranged from 0.048% to 1.58%, with higher risks observed for females, younger patients. Significant correlations were found between dose indices and technical parameters, including pitch, kVp, tube rotation time, and slice thickness (p < 0.005). Conclusions: The mean values for DLP, CTDIvol, and effective dose for abdominopelvic scans were higher than those found in previous studies, with significant correlation of weight on these values. Optimizing CT protocols and establishing DRLs tailored to clinical indications are critical for minimizing radiation exposure and enhancing patient safety.