The generally accepted model of the magnetic structure of an iron oxide core–shell nanoparticle includes a single-domain magnetically ordered core surrounded by a layer with a frozen spin disorder. Due to the exchange coupling between the shell and core, the spin disorder should lead to nonuniform magnetization in the core. Suppression of this inhomogeneity by an external magnetic field causes the nonlinear behavior of the magnetization as a function of the field in the region of the approach to magnetic saturation. The equation proposed to describe this effect is tested using a micromagnetic simulation. Analysis of the approach to magnetic saturation of iron oxide nanoparticles at different temperatures using this equation can be used to estimate the temperature evolution of the core–shell coupling energy and the size of the uniformly magnetized nanoparticle core and the temperature behavior of this size.
Magnetic microspheres with nonmagnetic acrylic glass core were fabricated using electroless deposition. There are favorable conditions for magnetic flux closure within each particle. As a result, the dipole-dipole interaction in the powder of such microspheres is reduced drastically. This is the key difference between powders of magnetic microspheres and powders of full magnetic spherical particles witch behavior is significantly affected by the dipole-dipole interaction. The magnetic hysteresis in the cobalt microspheres with nonmagnetic core is significantly large then in the full cobalt particles produced using the same technique. Keywords: Magnetic microspheres, magnetic dipole-dipole interaction.
Background: Glioblastoma remains a challenging brain tumor to treat due to its infiltrative nature. Accurately identifying tumor boundaries during surgery is crucial for successful tumor resection. This study introduces an innovative intraoperative visualization method utilizing a surgical fluorescence microscope to precisely locate tumor cells. The focus of the study is on IR-Glint, a novel preparation comprising Cy7.5-labeled aptamers Gli-233nt and Gli-55_3L specific to human glioblastoma. Methods: The aptamers were modified using molecular modeling and quantum chemical techniques. The effectiveness of the preparation was assessed using flow cytometry and microscopy on primary cultures of human glioblastoma. In vivo studies were conducted on mouse and rabbit models, employing orthotopic xenotransplantation of human brain glioblastoma with various imaging techniques, including PET/CT, in vivo fluorescence visualization, confocal laser scanning, and surgical microscopy. Results: The experiments validated the potential of IR-Glint for intraoperative visualization of glioblastoma using infrared imaging. Surface application of the aptamer-based formulation on the brain allowed clear visualization of the tumor, aiding surgeons in tumor resection. This approach also reduces the dosage required and mitigates potential toxic effects on the patient. Conclusions: This study demonstrates the promising potential of using in-frared dye-labeled aptamers for intraoperative visualization of glioblastoma. By improving surgical treatment outcomes in neurosurgery, this novel approach may pave the way for future advancements in the field.