Chun-Chun Hung

Dr. Chun-Chun Hung


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2023 in Energies
Verified
Journal Article
Open access
PDF file
MWMeng-Hui Wang
Meng-Hui Wang
CHChun-Chun Hung
Chun-Chun Hung
SLShiue-Der Lu
Shiue-Der Lu
LHLin Zong Han
Lin Zong Han
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
Faults in solar photovoltaic (PV) modules often result from component damage, leading to voltage fluctuations and decreased stability in the power system. In this study, the original voltage signals of different PV modules show little variation. Therefore, a solution that combines symmetrized dot pattern (SDP) and AlexNet for fault detection in PV modules was proposed. This solution investigates three common faults: poor welding, cracking, and bypass diode failure, which can be applied to fault-free modules. First, a high-frequency signal was input into the PV module, and the raw signal was captured using an NI PXI-5105 high-speed data acquisition card. Next, we used SDP to process the signal and create images with specific snowflake-like features. These images were used as a basis for fault diagnosis. Finally, deep-learning algorithms were used to perform status detection on the PV module. This research also used 3200 training samples and 800 test samples (200 for each type) to evaluate a new method for diagnosing faults in PV modules. The results show that the accuracy of the new method reached 99.8%, surpassing traditional convolutional neural networks (CNN) and extension neural networks (ENN), whose accuracies were 99.5% and 91.75%, respectively. Furthermore, this study compares the proposed method with more traditional numerical fault diagnosis methods. SDP effectively extracts fault signals and presents them as images. With AlexNet used for fault identification, the method excels in accuracy, training time, and testing time, thereby enhancing the stability and reliability of future energy systems.

12 May 2024 in Processes
Verified
Journal Article
Open access
PDF file
MWMeng-Hui Wang
Meng-Hui Wang
CHChun-Chun Hung
Chun-Chun Hung
SLShiue-Der Lu
Shiue-Der Lu
FCFu-Hao Chen
Fu-Hao Chen
YSYu-Xian Su
Yu-Xian Su
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
This study aims to develop a fault detection system designed specifically for wind turbine gearboxes. It proposes a hybrid fault diagnosis algorithm that combines scatter plot analysis with the visual geometric group (VGG) technique to identify various fault types, including gear rust, chipping, wear, and aging. To capture vibration signals, a three-axis vibration sensor was integrated with a NI-9234 DAQ card. Digital signal processing techniques were employed to actively filter out noise from the captured signals. Gaussian white noise was incorporated into the training data to enhance the noise resistance of the network model, which was then utilized for scatter plot generation. The VGG technique was subsequently applied to identify faults. The testing data were collected at two different speeds, with 1500 samples taken at each speed, totaling 3000 samples. For both training and testing, 400 samples of each fault type were employed for training, while 200 samples were allocated for testing. The test results demonstrated an overall identification accuracy of 97.7% for both the no-fault gearbox and the four-fault states, underscoring the effectiveness of the proposed methodology.

23 January 2026 in Processes
Verified
Journal Article
Open access
PDF file
CHChun-Chun Hung
Chun-Chun Hung
MWMeng-Hui Wang
Meng-Hui Wang
SLShiue-Der Lu
Shiue-Der Lu
Cheng-Chien KuoCheng-Chien Kuo
Cheng-Chien Kuo
This study aims to propose a fault diagnosis method for partial discharge (PD) in high-voltage (HV) potential transformers (PTs) by combining discrete wavelet transform (DWT), scatter plot (SP), and a residual neural network (ResNet) deep learning model for feature extraction and classification. First, models of HV PTs under normal conditions and three internal fault types were established, including coil eccentricity, voids between the primary winding and the core, and voids between the primary and secondary windings. After measuring the PD signals, DWT filtering was applied to process the signals, and the filtered PD signals, together with the fundamental voltage signals, were transformed into an image-based feature SP to represent the characteristics of each fault. Finally, the SPs were trained using the ResNet model to identify four different defect types in HV PTs. Experimental results showed that the proposed method achieves a fault identification accuracy of 98%. Additionally, compared to other deep learning models, the proposed method significantly improves diagnostic efficiency and accuracy. This study also developed an intelligent online fault monitoring and predictive maintenance system for HV PTs to enhance the stability of power grids and equipment.

23 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
MWMeng-Hui Wang
Meng-Hui Wang
YCYi cheng Chen
Yi cheng Chen
CHChun-Chun Hung
Chun-Chun Hung
With the increasing penetration of renewable energy, power system frequency stability faces multiple challenges. In addition to the decline of system inertia traditionally provided by synchronous machines, uncertainties such as wind power forecast errors, converter control characteristics, and stochastic load fluctuations further exacerbate the system’s sensitivity to power disturbances, increasing the risks of frequency deviation and instability. Among these factors, insufficient inertia is widely recognized as one of the most direct and critical drivers of the initial frequency response. This study focuses on this issue and explores the use of battery energy storage system (BESS) parameter optimization to enhance system stability. To this end, a simulation platform was developed in PSS®E V34 based on the IEEE New England 39-bus system, incorporating three wind turbines and two BESS units. The WECC generic models were adopted, and three wind disturbance scenarios were designed, including (i) disconnection of a single wind turbine, (ii) derating of two turbines to 50% output, and (iii) derating of three turbines to 50% output. In this study, a one-at-a-time (OAT) sensitivity analysis was first performed to identify the key parameters affecting frequency response, followed by optimization using an improved particle swarm optimization (IPSO) algorithm. The simulation results show that the minimum system frequency was 59.888 Hz without BESS control, increased to 59.969 Hz with non-optimized BESS control, and further improved to 59.976 Hz after IPSO. Compared with the case without BESS, the overall improvement was 0.088 Hz, of which IPSO contributed an additional 0.007 Hz. These results clearly demonstrate that IPSO can significantly strengthen the frequency support capability of BESS and effectively improve system stability under different wind disturbance scenarios.

29 June 2026 in Processes
Verified
Journal Article
Open access
PDF file
MWMeng-Hui Wang
Meng-Hui Wang
HCHsiang-Yun Cheng
Hsiang-Yun Cheng
HSHong-Wei Sian
Hong-Wei Sian
CHChun-Chun Hung
Chun-Chun Hung
As the offshore wind industry expands, improving operation and maintenance (O & M) efficiency while reducing the levelized cost of electricity (LCOE) has become increasingly important. This study develops an intelligent inspection route optimization framework for 21 offshore wind turbines located in the Changhua offshore wind farm of Taiwan. The framework integrates Geographic Information System (GIS) spatial information, dynamic sea-state conditions, labor costs based on Taiwan’s Labor Standards Act, and vessel fuel consumption into a comprehensive cost evaluation model. Particle Swarm Optimization (PSO) and Genetic Algorithm (GA) were applied to two practical scenarios: full-field routine inspections and targeted maintenance missions. Experimental results show that PSO achieved the shortest route for full-field inspections, reducing the travel distance to 20.125 km compared with 23.976 km obtained by GA. In contrast, for targeted maintenance involving eight turbines, GA generated a shorter route of 5.719 km, outperforming PSO’s 6.456 km. For the scenarios investigated in this study, PSO showed superior performance in the 21-turbine inspection task, whereas GA achieved better results in the 8-turbine maintenance task. The proposed framework provides an effective decision-support tool for offshore wind farm O & M planning, improving maintenance efficiency while reducing operational costs.

4 February 2026 in Energies
Verified
Journal Article
Open access
PDF file
MWMeng-Hui Wang
Meng-Hui Wang
YCYi cheng Chen
Yi cheng Chen
CHChun-Chun Hung
Chun-Chun Hung
HSHong-Wei Sian
Hong-Wei Sian
As wind penetration rises, the share of synchronous generation declines, reducing system inertia and increasing uncertainty in frequency stability; wind-output disturbances, power-electronic control characteristics, and stochastic load variations can further amplify frequency deviations caused by power imbalance. To improve frequency security under high wind penetration, this study optimizes BESS control parameters and evaluates their impact on system dynamic stability using a PSS®E V34 dynamic model of the IEEE New England 39-bus system that includes three wind turbines and two BESS units under four disturbance scenarios: (i) derating one turbine to 50%, (ii) tripping one turbine, (iii) derating all three turbines to 50%, and (iv) an N-1 contingency corresponding to the tripping of the largest conventional generator in the system. Morris sensitivity analysis is first applied to identify key parameters affecting frequency response and reduce the optimization dimension, and the selected parameters are then tuned using an improved genetic algorithm (IGA) and grey wolf optimization (GWO). Simulation results show the minimum frequency improves from 59.957 Hz (baseline) to 59.961 Hz with IGA and to 59.966 Hz with GWO, while the maximum equivalent power-angle difference in the BESS unit relative to the center of inertia decreases from 266.3° to 250.1° (IGA) and 251.2° (GWO), indicating that the proposed approach strengthens BESS frequency support and enhances dynamic stability under various wind-power and N-1 contingency disturbance conditions.