Yi cheng Chen

Mr. Yi cheng Chen


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
MWMeng-Hui Wang
Meng-Hui Wang
YCYi cheng Chen
Yi cheng Chen
CHChun-Chun Hung
Chun-Chun Hung
With the increasing penetration of renewable energy, power system frequency stability faces multiple challenges. In addition to the decline of system inertia traditionally provided by synchronous machines, uncertainties such as wind power forecast errors, converter control characteristics, and stochastic load fluctuations further exacerbate the system’s sensitivity to power disturbances, increasing the risks of frequency deviation and instability. Among these factors, insufficient inertia is widely recognized as one of the most direct and critical drivers of the initial frequency response. This study focuses on this issue and explores the use of battery energy storage system (BESS) parameter optimization to enhance system stability. To this end, a simulation platform was developed in PSS®E V34 based on the IEEE New England 39-bus system, incorporating three wind turbines and two BESS units. The WECC generic models were adopted, and three wind disturbance scenarios were designed, including (i) disconnection of a single wind turbine, (ii) derating of two turbines to 50% output, and (iii) derating of three turbines to 50% output. In this study, a one-at-a-time (OAT) sensitivity analysis was first performed to identify the key parameters affecting frequency response, followed by optimization using an improved particle swarm optimization (IPSO) algorithm. The simulation results show that the minimum system frequency was 59.888 Hz without BESS control, increased to 59.969 Hz with non-optimized BESS control, and further improved to 59.976 Hz after IPSO. Compared with the case without BESS, the overall improvement was 0.088 Hz, of which IPSO contributed an additional 0.007 Hz. These results clearly demonstrate that IPSO can significantly strengthen the frequency support capability of BESS and effectively improve system stability under different wind disturbance scenarios.

4 February 2026 in Energies
Verified
Journal Article
Open access
PDF file
MWMeng-Hui Wang
Meng-Hui Wang
YCYi cheng Chen
Yi cheng Chen
CHChun-Chun Hung
Chun-Chun Hung
HSHong-Wei Sian
Hong-Wei Sian
As wind penetration rises, the share of synchronous generation declines, reducing system inertia and increasing uncertainty in frequency stability; wind-output disturbances, power-electronic control characteristics, and stochastic load variations can further amplify frequency deviations caused by power imbalance. To improve frequency security under high wind penetration, this study optimizes BESS control parameters and evaluates their impact on system dynamic stability using a PSS®E V34 dynamic model of the IEEE New England 39-bus system that includes three wind turbines and two BESS units under four disturbance scenarios: (i) derating one turbine to 50%, (ii) tripping one turbine, (iii) derating all three turbines to 50%, and (iv) an N-1 contingency corresponding to the tripping of the largest conventional generator in the system. Morris sensitivity analysis is first applied to identify key parameters affecting frequency response and reduce the optimization dimension, and the selected parameters are then tuned using an improved genetic algorithm (IGA) and grey wolf optimization (GWO). Simulation results show the minimum frequency improves from 59.957 Hz (baseline) to 59.961 Hz with IGA and to 59.966 Hz with GWO, while the maximum equivalent power-angle difference in the BESS unit relative to the center of inertia decreases from 266.3° to 250.1° (IGA) and 251.2° (GWO), indicating that the proposed approach strengthens BESS frequency support and enhances dynamic stability under various wind-power and N-1 contingency disturbance conditions.