Frank Verhaegen

Prof. Frank Verhaegen


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2009 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
GPG Poludniowski
G Poludniowski
GLG Landry
G Landry
FDF DeBlois
F DeBlois
PEPhilip M evans
Philip M evans
FVFrank Verhaegen
Frank Verhaegen
A software program, SpekCalc, is presented for the calculation of x-ray spectra from tungsten anode x-ray tubes. SpekCalc was designed primarily for use in a medical physics context, for both research and education purposes, but may also be of interest to those working with x-ray tubes in industry. Noteworthy is the particularly wide range of tube potentials (40-300 kVp) and anode angles (recommended: 6-30 degrees) that can be modelled: the program is therefore potentially of use to those working in superficial/orthovoltage radiotherapy, as well as diagnostic radiology. The utility is free to download and is based on a deterministic model of x-ray spectrum generation (Poludniowski 2007 Med. Phys. 34 2175). Filtration can be applied for seven materials (air, water, Be, Al, Cu, Sn and W). In this note SpekCalc is described and illustrative examples are shown. Predictions are compared to those of a state-of-the-art Monte Carlo code (BEAMnrc) and, where possible, to an alternative, widely-used, spectrum calculation program (IPEM78).

25 September 2012 in Medical Physics
Verified
Journal Article
Open access
PDF file
LBLuc Beaulieu
Luc Beaulieu
ÅTÅsa Carlsson Tedgren
Åsa Carlsson Tedgren
JCJean‐François Carrier
Jean‐François Carrier
SDStephen D. Davis
Stephen D. Davis
FMFiras Mourtada
Firas Mourtada
JWJeffrey F. Williamson
Jeffrey F. Williamson
The charge of Task Group 186 (TG‐186) is to provide guidance for early adopters of model‐based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to ensure practice uniformity. Contrary to external beam radiotherapy, heterogeneity correction algorithms have only recently been made available to the BT community. Yet, BT dose calculation accuracy is highly dependent on scatter conditions and photoelectric effect cross‐sections relative to water. In specific situations, differences between the current water‐based BT dose calculation formalism (TG‐43) and MBDCAs can lead to differences in calculated doses exceeding a factor of 10. MBDCAs raise three major issues that are not addressed by current guidance documents: (1) MBDCA calculated doses are sensitive to the dose specification medium, resulting in energy‐dependent differences between dose calculated to water in a homogeneous water geometry (TG‐43), dose calculated to the local medium in the heterogeneous medium, and the intermediate scenario of dose calculated to a small volume of water in the heterogeneous medium. (2) MBDCA doses are sensitive to voxel‐by‐voxel interaction cross sections. Neither conventional single‐energy CT nor ICRU/ICRP tissue composition compilations provide useful guidance for the task of assigning interaction cross sections to each voxel. (3) Since each patient‐source‐applicator combination is unique, having reference data for each possible combination to benchmark MBDCAs is an impractical strategy. Hence, a new commissioning process is required. TG‐186 addresses in detail the above issues through the literature review and provides explicit recommendations based on the current state of knowledge. TG‐43‐based dose prescription and dose calculation remain in effect, with MBDCA dose reporting performed in parallel when available. In using MBDCAs, it is recommended that the radiation transport should be performed in the heterogeneous medium and, at minimum, the dose to the local medium be reported along with the TG‐43 calculated doses. Assignments of voxel‐by‐voxel cross sections represent a particular challenge. Electron density information is readily extracted from CT imaging, but cannot be used to distinguish between different materials having the same density. Therefore, a recommendation is made to use a number of standardized materials to maintain uniformity across institutions. Sensitivity analysis shows that this recommendation offers increased accuracy over TG‐43. MBDCA commissioning will share commonalities with current TG‐43‐based systems, but in addition there will be algorithm‐specific tasks. Two levels of commissioning are recommended: reproducing TG‐43 dose parameters and testing the advanced capabilities of MBDCAs. For validation of heterogeneity and scatter conditions, MBDCAs should mimic the 3D dose distributions from reference virtual geometries. Potential changes in BT dose prescriptions and MBDCA limitations are discussed. When data required for full MBDCA implementation are insufficient, interim recommendations are made and potential areas of research are identified. Application of TG‐186 guidance should retain practice uniformity in transitioning from the TG‐43 to the MBDCA approach.

17 October 2003 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
FVFrank Verhaegen
Frank Verhaegen
JSJan Seuntjens
Jan Seuntjens
An essential requirement for successful radiation therapy is that the discrepancies between dose distributions calculated at the treatment planning stage and those delivered to the patient are minimized. An important component in the treatment planning process is the accurate calculation of dose distributions. The most accurate way to do this is by Monte Carlo calculation of particle transport, first in the geometry of the external or internal source followed by tracking the transport and energy deposition in the tissues of interest. Additionally, Monte Carlo simulations allow one to investigate the influence of source components on beams of a particular type and their contaminant particles. Since the mid 1990s, there has been an enormous increase in Monte Carlo studies dealing specifically with the subject of the present review, i.e., external photon beam Monte Carlo calculations, aided by the advent of new codes and fast computers. The foundations for this work were laid from the late 1970s until the early 1990s. In this paper we will review the progress made in this field over the last 25 years. The review will be focused mainly on Monte Carlo modelling of linear accelerator treatment heads but sections will also be devoted to kilovoltage x-ray units and 60Co teletherapy sources.

1 August 2008 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
JWJohn Wong
John Wong
EAElwood Armour
Elwood Armour
PKPeter Kazanzides
Peter Kazanzides
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
ETErik Tryggestad
Erik Tryggestad
TDTheodore L. DeWeese
Theodore L. DeWeese

26 May 2011 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FVFrank Verhaegen
Frank Verhaegen
PGPatrick Granton
Patrick Granton
ETErik Tryggestad
Erik Tryggestad
Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research.

1 April 2016 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
WEWouter van Elmpt
Wouter van Elmpt
GLGuillaume Landry
Guillaume Landry
MDMarco Das
Marco Das
FVFrank Verhaegen
Frank Verhaegen