Walter Duarte de Araujo Filho

Dr. Walter Duarte de Araujo Filho


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
CMCarlos Toshiyuki Matsumi
Carlos Toshiyuki Matsumi
WSWilson José da Silva
Wilson José da Silva
FFábio Schneider
Fábio Schneider
JMJoaquim Miguel Maia
Joaquim Miguel Maia
RMRigoberto E.M. Morales
Rigoberto E.M. Morales
WFWalter Duarte de Araujo Filho
Walter Duarte de Araujo Filho
Microbubbles have various applications including their use as carrier agents for localized delivery of genes and drugs and in medical diagnostic imagery. Various techniques are used for the production of monodisperse microbubbles including the Gyratory, the coaxial electro-hydrodynamic atomization (CEHDA), the sonication methods, and the use of microfluidic devices. Some of these techniques require safety procedures during the application of intense electric fields (e.g., CEHDA) or soft lithography equipment for the production of microfluidic devices. This study presents a hybrid manufacturing process using micropipettes and 3D printing for the construction of a T-Junction microfluidic device resulting in simple and low cost generation of monodisperse microbubbles. In this work, microbubbles with an average size of 16.6 to 57.7 μm and a polydispersity index (PDI) between 0.47% and 1.06% were generated. When the device is used at higher bubble production rate, the average diameter was 42.8 μm with increased PDI of 3.13%. In addition, a second-order polynomial characteristic curve useful to estimate micropipette internal diameter necessary to generate a desired microbubble size is presented and a linear relationship between the ratio of gaseous and liquid phases flows and the ratio of microbubble and micropipette diameters (i.e., Qg/Ql and Db/Dp) was found.

20 September 2012 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
WFWalter Duarte de Araujo Filho
Walter Duarte de Araujo Filho
FFábio Schneider
Fábio Schneider
RMRigoberto E.M. Morales
Rigoberto E.M. Morales
Background: Micro bubbles were initially introduced as contrast agents for ultrasound examinations as they are able to modify the signal-to-noise ratio in imaging, thus improving the assessment of clinical information on human tissue. Recent developments have demonstrated the feasibility of using these bubbles as drug carriers in localized delivery. In micro fluidics devices for generation of micro bubbles, the bubbles are formed at interface of liquid gas through a strangulation process. A device that uses these features can produce micro bubbles with small size dispersion in a single step. Methods: A T-junction micro fluidic device constructed using 3D prototyping was made for the production of mono dispersed micro bubbles. These micro bubbles use sunflower oil as a lipid layer. Stability studies for micro bubbles with diameters different generated from a liquid phase of the same viscosity were conducted to evaluate whether micro bubbles can be used as drug carriers. The biocompatibility of coating layer, the ability to withstand environmental pressure variations combined with echogenicity, are key factors that they can safely play the role of drug transporters. Results: The normal distribution curve with small dispersion of the diameter of bubbles validates the process of generating micro bubbles with low value of variation coefficient, i.e., 0.381 at 1.90%. The results also showed the feasibility of using sunflower oil as the lipid matrix with stable population of bubbles over 217 minutes for micro bubbles with an average diameter of 313.04 μm and 121 minutes for micro bubbles with an average diameter of 73.74 μm, considering bubbles with air as gaseous phase. Conclusion: The results indicate that the micro fluidic device designed can be used for producing micro bubbles with low variation coefficient using sunflower oil as a coating of micro bubbles. These carriers were stable for periods of time that are long enough for clinical applications even when regular air is used as the gas phase. Improved stability can be achieved when biocompatible gas with lower permeability is used.

20 September 2017 in International Journal of Biosensors & Bioelectronics
Verified
Journal Article
Open access
PDF file
WFWalter Duarte de Araujo Filho
Walter Duarte de Araujo Filho

12 April 2026 in Revista Tópicos
Verified
Journal Article
Open access
PDF file
HDHerlon Dionatan da Purificação Dias
Herlon Dionatan da Purificação Dias
WFWalter Duarte de Araujo Filho
Walter Duarte de Araujo Filho
ANAna Paula Santos Nascimento
Ana Paula Santos Nascimento
EPEdson Silva Pinho
Edson Silva Pinho
JAJulio José de Oliveira Aquino
Julio José de Oliveira Aquino
JSJosé Vicente Cardoso Santos
José Vicente Cardoso Santos
No mundo contemporâneo verifica-se uma forte tendência de ocorrências de ambientes com forte densidade sonora gerando demandas de ordem orgânica, social e até mesmo psicológicas, gerando aspectos negativos ao ser humano e forte reatividade a esse cenário. Com isso o objetivo geral dessa pesquisa é investigar o nível de intensidade sonora na praça de alimentação do Shopping da Bahia ao longo do dia, comparando os resultados com parâmetros de risco e conforto auditivo para os seres humanos; e, como o objetivos específicos: a) Medir o nível sonoro em cinco horários distintos (10h, 13h, 16h, 19h e 21h) com duração de 10 minutos por horário; b) Identificar horários de maior risco de exposição sonora e discutir potenciais fontes do ruído observadas no local; e c) Relacionar os resultados obtidos com os limites de exposição e recomendações sobre os efeitos no sistema auditivo. Para consolidar esses objetivos adota-se uma um estudo que caracteriza-se como uma pesquisa aplicada, de abordagem predominantemente quantitativa, com suporte qualitativo interpretativo, de natureza descritiva e exploratória. Quanto aos procedimentos técnicos, configura-se como um estudo de campo, de caráter observacional e não experimental, com coleta de dados por meio de levantamento instrumental. Do ponto de vista temporal, trata-se de um estudo transversal, realizado em um único dia, sem controle de variáveis externas, típico de investigações em ambiente natural. No aspecto experimental foi necessária a instalação, no smartphone de cada membro do grupo, o aplicativo "Decibelímetro: Aplicativo Medidor de Som", o qual é capaz de gerar um gráfico instantâneo do NIS em função do tempo. Foram analisadas também condições ambientais, como a temperatura e a pressão do ambiente. A análise confronta os valores obtidos com conceitos e limites de referência presentes na literatura de acústica. Foram abordados, ainda, os efeitos sobre a audição humana e as recomendações normativas estabelecidas pela ABNT NBR 10152. Conclui-se que, em diversos horários, os níveis medidos ultrapassam valores que representam risco de dano auditivo aos seres humanos quando submetidos à exposição prolongada.