Joaquim Miguel Maia

Prof. Dr. Joaquim Miguel Maia

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2009 in Brazilian Journal of Medical and Biological Research
Verified
Journal Article
Open access
PDF file
RRR.J. Riella
R.J. Riella
PNP. Nohama
P. Nohama
JMJoaquim Miguel Maia
Joaquim Miguel Maia
The present report describes the development of a technique for automatic wheezing recognition in digitally recorded lung sounds. This method is based on the extraction and processing of spectral information from the respiratory cycle and the use of these data for user feedback and automatic recognition. The respiratory cycle is first pre-processed, in order to normalize its spectral information, and its spectrogram is then computed. After this procedure, the spectrogram image is processed by a two-dimensional convolution filter and a half-threshold in order to increase the contrast and isolate its highest amplitude components, respectively. Thus, in order to generate more compressed data to automatic recognition, the spectral projection from the processed spectrogram is computed and stored as an array. The higher magnitude values of the array and its respective spectral values are then located and used as inputs to a multi-layer perceptron artificial neural network, which results an automatic indication about the presence of wheezes. For validation of the methodology, lung sounds recorded from three different repositories were used. The results show that the proposed technique achieves 84.82% accuracy in the detection of wheezing for an isolated respiratory cycle and 92.86% accuracy for the detection of wheezes when detection is carried out using groups of respiratory cycles obtained from the same person. Also, the system presents the original recorded sound and the post-processed spectrogram image for the user to draw his own conclusions from the data.

1 January 2013 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
JMJoaquim Miguel Maia
Joaquim Miguel Maia
FFábio Schneider
Fábio Schneider
VBVera Lsn Button
Vera Lsn Button
ECEduardo T Costa
Eduardo T Costa
In ultrasound imaging systems, the digital transmit beamformer is a critical module that generates accurate control over several transmission parameters. However, such transmit front-end module is not typically accessible to ultrasound researchers. To overcome this difficulty, we have been developing a compact and fully programmable digital transmit system using the pulse-width modulation (PWM) technique for generating simultaneous arbitrary waveforms, specifically designed for research purposes. In this paper we present a reconfigurable arbitrary waveform generator (RAWG) for ultrasound research applications that exploits a high frequency PWM scheme implemented in a low-cost FPGA, taking advantage of its flexibility and parallel processing capability for independent controlling of multiple transmission parameters. The 8-channel platform consists of a FPGA-based development board including an USB 2.0 interface and an arbitrary waveform generator board with eight MD2130 beamformer source drivers for individual control of waveform, amplitude apodization, phase angle and time delay trigger. To evaluate the efficiency of our system, we used equivalent RC loads (1 kΩ and 220 pF) to produce arbitrary excitation waveforms with the Gaussian and Tukey profiles. The PWM carrier frequency was set at 160 MHz featuring high resolution while keeping a minimum time delay of 3.125 ns between pulses to enable the acoustic beam to be focused and/or steered electronically. Preliminary experimental results show that the RAWG can produce complex arbitrary pulses with amplitude over 100 Vpp and central frequency up to 20 MHz with satisfactory linearity of the amplitude apodization, as well as focusing phase adjustment capability with angular resolution of 7.5°. The initial results of this study showed that the proposed research system is suitable for generating simultaneous arbitrary waveforms, providing extensive user control with direct digital access to the various transmission parameters needed to explore alternative ultrasound transmission techniques.

13 August 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
AZAcácio José Zimbico
Acácio José Zimbico
DGDiogo Watchel Granado
Diogo Watchel Granado
FSFabio Kurt Schneider
Fabio Kurt Schneider
JMJoaquim Miguel Maia
Joaquim Miguel Maia
AAAmauri Amorin Assef
Amauri Amorin Assef
ECEduardo Tavares Costa
Eduardo Tavares Costa
The eigenspace generalized sidelobe canceller (EGSC) beamformer combined with a signal-to-noise ratio (SNR) dependent coherence factor (CF) is suggested for coherent plane wave compounding (PW) imaging. Conventional CF based methods such as generalized CF and subarray CF can improve the image quality, however, they are not suitable for low SNR. On the other hand, the EGSC CF based approach can introduce improvements in image quality, however, in PW imaging is susceptible to suffer from degradation due to low SNR which leads to a poor image quality. To overcome this limitation, the SNR dependent CF method is suggested for application in such situations due to its ability to control the SNR levels. The Field II and the Verasonics ultrasound imaging system with a L11-4v array transducer with a contrast resolution phantom were used to capture the plane wave sequences of simulation and experimental data, respectively. The performance evaluation using full width at half maximum (FWHM), contrast (CR and CNR) and the speckle statistics by using the signal to noise ratio (SNR) complemented by the Rayleigh distribution analysis was performed. In order to evaluate the performance of the $$\text {EGSC}_{3}$$ (the SNR CF) beamformer, the comparison is done with particular importance to other CF-based approaches such as $$\text {EGSC}_{1}$$ (the generalized CF) and, $$\text {EGSC}_{2}$$ (the subarray CF) respectively. Taking DAS as reference, $$\text {EGSC}_3$$ showed 30.3 and 39.5% of improvement for $$\text {CR(dB)}$$ and $$\text {CNR}$$ , respectively, when using experimental data. The proposed method also slightly outperforms the $$\text {EGSC}_1$$ and $$\text {EGSC}_2$$ methods for $$\text {CR(dB)}$$ , $$\text {CNR}$$ , and speckle statistics assessment. The $$\text {EGSC}_3$$ is, therefore, suitable for CPWC by improving the spatial resolution and contrast while preserving the speckle pattern.

23 May 2003
Verified
Conference Paper
Closed access
PDF file
VNValeria Monteiro Do Nascimento
Valeria Monteiro Do Nascimento
VBVera Lúcia da Silveira Nantes Button
Vera Lúcia da Silveira Nantes Button
JMJoaquim Miguel Maia
Joaquim Miguel Maia
ECEduardo Tavares Costa
Eduardo Tavares Costa
EOEduardo Jorge Valadares Oliveira
Eduardo Jorge Valadares Oliveira
In this work we have investigated the influence of the backing layer composition and the matching layer thickness in the performance of ultrasound transducers constructed with piezoelectric ceramic disks. We have constructed transducers with backing layers of different compositions, using mixtures of epoxy with alumina powder and/or Tungsten powder and with λ/4 or 3λ/4 thickness epoxy matching layers. The evaluation tests were performed in pulse-echo mode, with a flat target, and in transmission/reception mode, with a calibrated PVDF hydrophone. The acoustical field emitted by each transducer was mapped in order to measure the on-axis and transverse field profiles, the aperture size and the beam spreading. The bandwidths of the transducers were determined in pulse-echo mode. Comparing the evaluation tests results of two transducers constructed with the same backing layer, the one constructed with λ/4 thickness epoxy matching layer showed better performance. The results showed that the transducers constructed with epoxy, alumina and Tungsten powders backing layers have larger bandwidth. The larger depth of field was measured for transducers constructed with epoxy and Tungsten powder backing layers. These transducers and those constructed with epoxy, Tungsten and alumina powders backing layers showed the larger field intensities in the measured transverse profiles.

28 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
NJNivaldo Theodoro Schiefler Jr.
Nivaldo Theodoro Schiefler Jr.
JMJoaquim Miguel Maia
Joaquim Miguel Maia
FFábio Schneider
Fábio Schneider
AZAcácio José Zimbico
Acácio José Zimbico
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
ECEduardo T. Costa
Eduardo T. Costa
Ultrasonic imaging is one of the most important techniques to help medical diagnosis. However, obtaining high quality images requires the acquisition, processing, and storage of a large amount of data. In this work, we evaluated a new ultrasound imaging technique based on plane wave and sparse arrays to increase the scan rate and reduce the amount of data amount to be stored. The performance of the proposed method was tested using simulated echo data (from Field II) and phantom data acquired using a Verasonics system equipped with a L11-4v linear array transducer. The tests were done using 128 elements for transmission and 128, 65, 44, and 23 elements sparsely distributed for reception. The simulated data were compared with images obtained with the Delay and Sum (DAS) method and the experimental data were compared with those acquired from Verasonics. The obtained results using the Full Width at Half Maximum (FWHM) criteria at −6 dB showed that the images generated by the proposed method were similar in terms of resolutions (axial and lateral) and contrast to the simulated and the Verasonics commercial ones, indicating that the sparse reception proposed method is suitable for ultrasound imaging.

1 September 2015 in Research on Biomedical Engineering
Verified
Journal Article
Open access
PDF file
Amauri Amorin AssefAmauri Amorin Assef
Amauri Amorin Assef
JMJoaquim Miguel Maia
Joaquim Miguel Maia
ECEduardo Tavares Costa
Eduardo Tavares Costa
IntroductionIn this paper, we present the initial results of a fully programmable 128-channel FPGA and PC-based system that has been developed for medical ultrasound (US) imaging research in our University laboratory (Federal University of Technology - Paraná, Brazil).MethodsIn order to demonstrate the feasibility of the US research system, two applications involving unfocused plane wave transmission and conventional B-mode beamforming were evaluated using a commercial tissue-mimicking phantom and a 3.2 MHz 128-element convex array transducer.ResultsTesting results show that the hardware platform is able to synthesize arbitrary pulses up to 100 Vpp with second order harmonic distortion below 80 dB. For the first application, a 41-tap digital FIR bandpass filter was applied to the acquired RF echoes, sampled at 40 MHz with 12-bit resolution, to improve the noise suppression. In the second application, after offline apodization weighting, filtering, delay-and-sum processing, envelope detection, log compression and scan conversion, the reconstructed B-mode image is displayed over a 50 dB range.DiscussionThe presented results indicate that the open US imaging system can be used to support different ultrasonic transmission and reception strategies, which typically cannot be implemented in conventional data flow architectures that are mainly based on hardware