Downwind turbines have favorable characteristics such as effective energy capture in up-flow wind conditions over complex terrains. They also have reduced risk of severe accidents in the event of disruptions to electrical networks during strong storms due to the free-yaw effect of downwind turbines. These favorable characteristics have been confirmed by wind-towing tank experiments and computational fluid dynamics (CFD) simulations. However, these advantages have not been fully demonstrated in field experiments on actual wind farms. In this study—although the final objective was to demonstrate the potential advantages of downwind turbines through field experiments—field measurements were performed using a vertical-profiling light detection and ranging (LiDAR) system on a wind farm with downwind turbines installed in complex terrains. To deduce the horizontal wind speed, vertical-profiling LiDARs assume that the flow of air is uniform in space and time. However, in complex terrains and/or in wind farms where terrain and/or wind turbines cause flow distortion or disturbances in time and space, this assumption is not valid, resulting in erroneous wind speed estimates. The magnitude of this error was evaluated by comparing LiDAR measurements with those obtained using a cup anemometer mounted on a meteorological mast and detailed analysis of line-of-sight wind speeds. A factor that expresses the nonuniformity of wind speed in the horizontal measurement plane of vertical-profiling LiDAR is proposed to estimate the errors in wind speed. The possibility of measuring and evaluating various wind characteristics such as flow inclination angles, turbulence intensities, wind shear and wind veer, which are important for wind turbine design and for wind farm operation is demonstrated. However, additional evidence of actual field measurements on wind farms in areas with complex terrains is required in order to obtain more universal and objective evaluations.
24 December 2022 in Experimental Thermal and Fluid Science
This study deals with the studies of the effect of double flow-control devices (DFCDs) on turbine vane film cooling. Aiming for improving film effectiveness, two semispheroid DFCDs per pitch were attached to the vane surface upstream of the cooling hole. Although the DFCDs were successfully applied to the flat-plate film cooling in the previous study, the applicability to the turbine vane was to be investigated. In order to observe the flow field in detail, Reynolds-averaged Navier–Stokes (RANS) simulation was conducted first. The DFCDs were installed upstream of each cooling hole of the pressure and suction sides of the vane to investigate the effect of the device position. In this paper, the effects of blowing ratio and cooling hole pitch were also investigated. The results obtained by CFD showed that the vortex generated from DFCD suppressed lift-off of the secondary air. As a result, the film effectiveness became significantly higher than that without DFCD condition. Moreover, the improvement in the film effectiveness by DFCD was observed by both of the pressure and suction sides of the turbine vane. Based on the findings through RANS simulation, adiabatic effectiveness and total pressure loss coefficient measurement were performed in a linear cascade test facility. The experiment confirmed that the film effectiveness was improved when DFCDs existed.
The leading-edge erosion of a wind turbine blade was tested using a whirling arm rain erosion tester, whose rotation rate is considerably higher than that of a full-scale wind turbine owing to the scale effect. In this study, we assessed the impact pressure of droplets on a wet surface of wind turbine blades using numerical simulation of liquid droplet impact by solving the Navier–Stokes equations combined with the volume-of-fluid method. This was conducted in combination with an estimation of liquid film thickness on the rotating blade using an approximate solution of Navier–Stokes equations considering the centrifugal and Coriolis forces. Our study revealed that the impact pressure on the rain erosion tester exceeded that on the wind turbine blade, attributed to the thinner liquid film on the rain erosion tester than on the wind turbine blade caused by the influence of centrifugal and Coriolis forces. This indicates the importance of correcting the influence of liquid-film thickness in estimating the impact velocity of droplets on the wind turbine blade. Furthermore, we demonstrated the correction procedure when estimating the impact velocity of droplets on the wind turbine blade.
Dielectric barrier discharge plasma actuators (DBD-PAs) have the potential to improve the performance of fluid machineries such as aircrafts and wind turbines by preventing flow separation. In this study, to identify the multiple flow control mechanisms in high Reynolds number flow, parametric experiments for an actuation parameter with a wide range of Re values (105–106) for NACA0015 airfoil was conducted. We conducted wind tunnel tests by applying a DBD-PA to the flow field around a wing model at the leading edge. Lift characteristics, turbulent kinetic energy in the flow field, shear layer height, and the separation point of the boundary layer were evaluated based on pressure distributions on the wing surface and velocity of the flow field, with the effect of DBD-PA on the post-stall flow around the wing and the mechanism behind the increase in the lift coefficient analyzed based on these evaluation results. The following phenomena contributed to the increase in : (1) increase in turbulent kinetic energy; (2) increase in circulation; and (3) acceleration of the flow near the leading edge. Thus, this study effectively investigated the dependence of the increase in lift on and the lift-increasing mechanism for a wide range of Re values.
1 January 2019 in The Proceedings of Mechanical Engineering Congress, Japan