Derek Goderis

Mr. Derek Goderis

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2024 in Aerosol Science and Technology
Verified
Journal Article
Closed access
DGDerek Goderis
Derek Goderis
YXYao Xiao
Yao Xiao
AAAli Alotbi
Ali Alotbi
AAArsh Ahtsham
Arsh Ahtsham
JDJ. Timothy Dvonch
J. Timothy Dvonch
AAAndrew Ault
Andrew Ault
The impact of suspended particles on health, climate, and industrial applications is highly size-dependent. Thus, regulations are typically based on particles with diameters below a specific size, such as particulate matter less than 2.5 μm (PM2.5). For over a century, cyclones have been employed to isolate particles below a certain diameter by removing large particles from a gas stream, but cyclones are typically relatively large, heavy, and expensive to fabricate compared to objects made with low-cost 3-dimensional (3D) printers. Herein, we present one-piece 3D-printed micro-cyclones (PM2.5 and PM1) to isolate particles smaller than a specific diameter. The collection efficiencies and 50% cut-off diameters (d50) of multiple cyclones were evaluated with both monodisperse and polydisperse standards ranging from 0.1 to 3 μm, as well as ambient aerosol. By altering the inlet orientation relative to the micro-cyclone centerline (orthogonal, 50% offset, and fully offset), we show that shifting the inlet radially outward increased the steepness of the transmission curve resulting in a sharper cut-point. The d50 also decreased below the designed for diameter, (PM1 = 1.4, 1.0, and 0.9 μm; PM2.5 = 3.2, 2.0, 1.9 μm), which was attributed to imperfect models, internal surface roughness, and print errors versus machining. These single piece, 3D-printed cyclones provide a cheaper (< $1), faster, and more accessible approach to manufacture micro-cyclones for use in a range of aerosol applications.

1 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
EAEhsan Ashoori
Ehsan Ashoori
DGDerek Goderis
Derek Goderis
AIAnna Inohara
Anna Inohara
AMAndrew J. Mason
Andrew J. Mason
Electrochemical measurements are vital to a wide range of applications such as air quality monitoring, biological testing, food industry, and more. Integrated circuits have been used to implement miniaturized and low-power electrochemical potentiostats that are suitable for wearable devices. However, employing modern integrated circuit technologies with low supply voltage precludes the utilization of electrochemical reactions that require a higher potential window. In this paper, we present a novel circuit architecture that utilizes dynamic voltage at the working electrode of an electrochemical cell to effectively enhance the supported voltage range compared to traditional designs, increasing the cell voltage range by 46% and 88% for positive and negative cell voltages, respectively. In return, this facilitates a wider range of bias voltages in an electrochemical cell, and, therefore, opens integrated microsystems to a broader class of electrochemical reactions. The circuit was implemented in 180 nm technology and consumes 2.047 mW of power. It supports a bias potential range of 1.1 V to −2.12 V and cell potential range of 2.41 V to −3.11 V that is nearly double the range in conventional designs.

23 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
SLSamuel Lobert
Samuel Lobert
Zahid Rashid SheikhZahid Rashid Sheikh
Zahid Rashid Sheikh
NYNavid Yazdi
Navid Yazdi
DGDerek Goderis
Derek Goderis
AMAndrew J. Mason
Andrew J. Mason
Electrochemical sensor arrays that perform simultaneous multi-technique (SMT) measurements within a shared electrolyte are essential for continuous, multi-analyte detection in microfluidic platforms for environmental and healthcare monitoring. This review examines the potentiostat architectures and electrode geometries relevant to SMT operation. Traditional single channel and multi-electrode potentiostat topologies are surveyed, and their suitability for multi-cell shared-electrolyte environments is evaluated. Additionally, crosstalk mechanisms in shared electrolytes are classified into chemical, electrical, and a newly identified category termed stability-based interference, which arises from conflicting feedback loops in conventional grounded working electrode instrumentation. A survey of existing multi-cell platforms reveals that most reported systems either avoid true SMT operation or address crosstalk primarily through electrode geometry without systematic evaluation of instrumentation effects. Based on this analysis, we introduce an instrumentation and electrode geometry co-design framework that provides a unified design pathway toward continuous multi-analyte microfluidic sensors for wearable and point-of-care applications.