Ehsan Ashoori

Mr. Ehsan Ashoori

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
HLHaitao Li
Haitao Li
SPSina Parsnejad
Sina Parsnejad
EAEhsan Ashoori
Ehsan Ashoori
CTCort Thompson
Cort Thompson
EPErin Purcell
Erin Purcell
AMAndrew J. Mason
Andrew J. Mason
High-density on-chip electrochemical biosensor arrays are advancing toward a crucial role in health monitoring and development of new medicines and medical treatments. Nanopore and ion channel based sensors especially have great potential but present demanding resolution/speed/power/area requirements on instrumentation circuits. This paper presents a pixel-level current readout circuit and new group-cluster architecture to address the circuit challenges in high-performance biosensor arrays. Fabricated in 0.5 μm CMOS, this electrochemical voltammetry circuit achieves 7.2 pArms noise in an 11.5-kHz bandwidth and only consumes 21-μ W power and 0.06 mm 2 area per readout channel. Cyclic voltammetry experiments in a potassium ferricyanide solution and patch-clamp whole-cell experiments were performed to validate the circuit's feasibility for electrochemical biosensor applications.

1 October 2016
Verified
Conference Paper
Closed access
SPSina Parsnejad
Sina Parsnejad
YHYaoxing Hu
Yaoxing Hu
HWHao Wan
Hao Wan
EAEhsan Ashoori
Ehsan Ashoori
AMAndrew J. Mason
Andrew J. Mason
This paper presents a multi-channel, multi-technique electrochemical instrument with the size, power and performance for portable applications such as point-of-care diagnosis, wearable sensing, and toxic chemical detection. Composed of a custom analog interface and a commercial low-power microcontroller, the portable instrument is capable of dynamically adapting to a wide input current range exhibited by many electrode/sensor types and observed in the transient response of many electrochemical techniques. The instrument can generate several standard electrochemical stimulus waveforms or an arbitrary waveform, independently and in parallel on multiple channels, while streaming measurement results to a USB host. The portable instrument was tested across multiple conditions against a commercial benchtop electrochemical instrument in a potassium ferricyanide solution. The maximum normalized root mean square difference between test results and the commercial instrument is less than 2%, cementing system robustness.

1 August 2011
Verified
Conference Paper
Closed access
EAEhsan Ashoori
Ehsan Ashoori
FAFarzad Asgarian
Farzad Asgarian
ASAmir M. Sodagar
Amir M. Sodagar
EYEuisik Yoon
Euisik Yoon
In this paper employing double layer printed spiral coils (PSCs) is proposed for wireless power transmission in implantable biomedical applications. Detailed modeling of this type of PSCs is presented. Both calculations and measurements of fabricated double layer PSCs indicate that this structure can decrease the size of typical single layer PSCs without any change in the most important parameters of the coils, such as quality factor. Also, it is shown that with equal PSC dimensions and design parameters, double layer PSCs achieve significantly higher inductances and quality factors. Ultimately, a pair of double layer PSCs with a distance of 5 mm in air is used in an inductive link. The power transfer efficiency of this link is about 79.8% with a carrier frequency of 5 MHz and coupling coefficient of 0.189.

1 May 2018
Verified
Conference Paper
Closed access
EAEhsan Ashoori
Ehsan Ashoori
SDSylmarie Davila-Montero
Sylmarie Davila-Montero
AMAndrew J. Mason
Andrew J. Mason
High channel count neural implants that can record brain activities across diverse cortical regions represent the next step toward whole brain interfaces that will enable new understanding of brain operation and treatment of many neural disorders. To overcome the size and power constraints limiting the channel count of existing neural implants, this paper presents a new neural amplifier array design that utilizes hardware sharing to achieve low power and compact size. Moreover, to ease the burden of large volume data handling, in-situ data decimation is performed to enable off body evaluation of synchrony between signal pairs. A 32-channel analog front end array was designed and post-layout simulations show that the entire front end occupies only 0.031 mm 2 per channel while consuming only 3.34 μW per channel at 3.3 V in 0.5 μm CMOS. This front end decimates data by an order of magnitude while keeping the synchrony information with more than 89.1% accuracy.

1 October 2018
Verified
Conference Paper
Closed access
EAEhsan Ashoori
Ehsan Ashoori
HYHeyu Yin
Heyu Yin
SPSina Parsnejad
Sina Parsnejad
JSJoseph Salatino
Joseph Salatino
EPErin Purcell
Erin Purcell
AMAndrew J. Mason
Andrew J. Mason
ECoG electrode arrays offer great potential for high-channel-count monitoring of large scale brain activity. However, scaling ECoG recording systems to high channel count is challenging due to the large silicon area demanded by the coupling capacitors necessary for DC offset voltage rejection. This paper presents a new approach to reduce the per-channel area of recording circuits by introducing a capacitor-embedded ECoG electrode structure that implements coupling capacitors within the existing electrode area. For proof of concept, a 4×4 array of 8 pF capacitor-embedded electrodes was fabricated in a 2mm × 2mm area using a three-mask process to form a capacitor stack of Cu, Ta 2 O 5 , and Ti/Cu/ Au. In vivo experiments performed on an adult rat show that physiologically-evoked activity was accurately detected according to the placement of the electrodes for manual whisker deflection, shoulder tapping and hindlimb tapping. The capacitor-embedded ECoG electrode structure provides a new method for achieving high channel count neural recording.

1 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
EAEhsan Ashoori
Ehsan Ashoori
DGDerek Goderis
Derek Goderis
AIAnna Inohara
Anna Inohara
AMAndrew J. Mason
Andrew J. Mason
Electrochemical measurements are vital to a wide range of applications such as air quality monitoring, biological testing, food industry, and more. Integrated circuits have been used to implement miniaturized and low-power electrochemical potentiostats that are suitable for wearable devices. However, employing modern integrated circuit technologies with low supply voltage precludes the utilization of electrochemical reactions that require a higher potential window. In this paper, we present a novel circuit architecture that utilizes dynamic voltage at the working electrode of an electrochemical cell to effectively enhance the supported voltage range compared to traditional designs, increasing the cell voltage range by 46% and 88% for positive and negative cell voltages, respectively. In return, this facilitates a wider range of bias voltages in an electrochemical cell, and, therefore, opens integrated microsystems to a broader class of electrochemical reactions. The circuit was implemented in 180 nm technology and consumes 2.047 mW of power. It supports a bias potential range of 1.1 V to −2.12 V and cell potential range of 2.41 V to −3.11 V that is nearly double the range in conventional designs.