Damber Thapa

Dr. Damber Thapa

orcid

Research Focus & Metrics

Representative Publications

View All Publications
22 December 2023 in Science Advances
Verified
Journal Article
Open access
DTDamber Thapa
Damber Thapa
PTPantea Tavakolian
Pantea Tavakolian
GZGeorge Zhou
George Zhou
AZAlan Zhang
Alan Zhang
AAAsser Abdelgawad
Asser Abdelgawad
AMAndreas Mandelis
Andreas Mandelis
Spatial super-resolution in thermophotonic imaging was achieved using a combination of spatial second-derivative forming, spatial gradient adaptive filtering, and Richardson-Lucy deconvolution in conjunction with the construction of an experimental point spread function. When implemented through enhanced truncation-correlation photothermal coherence tomography (eTC-PCT), it was possible to restore blurred infrared thermophotonic images to their prediffusion optical resolution state. This modality was tested in various biological applications and proved to be capable of imaging fine axial cracks in human teeth, well-patterned anatomical subsurface structures of a mouse brain, and neovascularization in a mouse thigh due to the rapid proliferation of cancer cells. This modality was found to be immune to optical scattering and could reveal the true spatial extent of biological features at subsurface depths that conventional thermal imaging cannot reach because of limitations imposed by the physics of spreading diffusion.

23 June 2016 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
XZXiaohui Zhao
Xiaohui Zhao
DTDamber Thapa
Damber Thapa
BWBenquan Wang
Benquan Wang
YLYiming Lu
Yiming Lu
SGShaoyan Gai
Shaoyan Gai
Xincheng YaoXincheng Yao
Xincheng Yao
Rod-dominated transient retinal phototropism (TRP) has been recently observed in freshly isolated mouse and frog retinas. Comparative confocal microscopy and optical coherence tomography revealed that the TRP was predominantly elicited from the rod outer segment (OS). However, the biophysical mechanism of rod OS dynamics is still unknown. Mouse and frog retinal slices, which displayed a cross-section of retinal photoreceptors and other functional layers, were used to test the effect of light stimulation on rod OSs. Time-lapse microscopy revealed stimulus-evoked conformational changes of rod OSs. In the center of the stimulated region, the length of the rod OS shrunk, while in the peripheral region, the rod OS swung toward the center region. Our experimental observation and theoretical analysis suggest that the TRP may reflect unbalanced rod disc-shape changes due to localized visible light stimulation.

1 May 2014 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
DTDamber Thapa
Damber Thapa
Kaamran RaahemifarKaamran Raahemifar
Kaamran Raahemifar
WBWilliam R. Bobier
William R. Bobier
Vasudevan LakshminarayananVasudevan Lakshminarayanan
Vasudevan Lakshminarayanan
A critical challenge in biomedical imaging is to optimally balance the trade-off among image resolution, signal-to-noise ratio, and acquisition time. Acquiring a high-resolution image is possible; however, it is either expensive or time consuming or both. Resolution is also limited by the physical properties of the imaging device, such as the nature and size of the input source radiation and the optics of the device. Super-resolution (SR), which is an off-line approach for improving the resolution of an image, is free of these trade-offs. Several methodologies, such as interpolation, frequency domain, regularization, and learning-based approaches, have been developed over the past several years for SR of natural images. We review some of these methods and demonstrate the positive impact expected from SR of retinal images and investigate the performance of various SR techniques. We use a fundus image as an example for simulations.

14 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DTDamber Thapa
Damber Thapa
NSNakisa Samadi
Nakisa Samadi
NTNima Tabatabaei
Nima Tabatabaei
With the emergence of vaccines and antibody therapeutics, rapid and scalable platforms are needed to quantify the antibody response of individuals. Lateral flow immunoassay (LFA) based test strips provide a rapid, low-cost, and point-of-care approach to antibody testing against the SARS-CoV-2 virus. These convenient and scalable tests, however, are qualitative in nature and cannot quantify the immune response of the infected and/or vaccinated individuals. This study reports on the development of a rapid, low cost and portable thermo-photonic device that enables sensitive detection and quantification of antibody levels using commercially available COVID-19 Antibody LFAs. Unlike conventional LFA readers, the developed technology is based on sensing the infrared thermal radiation of tag gold nanoparticles following laser excitation (aka photothermal response). Our proof-of-concept results with humanized monoclonal anti-SARS-CoV-2 Spike receptor-binding domain (RBD) IgG demonstrate that the thermo-photonic technology can detect and quantify antibody concentrations within the clinically relevant range and with a limit of detection of $0.1~\mu \text{g}$ /ml. The reader in conjunction with antibody LFAs offers a low-cost, portable, and scalable solution for assessment of the degree of immunity in populations, quality control of convalescent plasma donations for antibody therapeutics, and monitoring the immune response of infected individuals and vaccine recipients.

24 March 2011 in Journal of Modern Optics
Verified
Journal Article
Closed access
DTDamber Thapa
Damber Thapa
AFAndre Fleck
Andre Fleck
Vasudevan LakshminarayananVasudevan Lakshminarayanan
Vasudevan Lakshminarayanan
WBWilliam R. Bobier
William R. Bobier
Hartmann–Shack images taken from an archived collection of SureSight refractive measurements of pre-school children in Oxford County, Ontario, Canada were retrieved and re-analyzed. Higher-order aberrations were calculated over the age range of 3 to 6 years. These higher-order aberrations were compared with respect to magnitudes of ametropia. Subjects were classified as emmetropic (range −0.5 to + 0.5D), low hyperopic (+ 0.5 to +2D) and high hyperopic (+2D or more) based upon the resulting spherical equivalent. Higher-order aberrations were found to increase with higher levels of hyperopia (p < 0.01). The strongest effect was for children showing more than +2.00D of hyperopia. The correlation coefficients were small in all of the higher-order aberrations; however, they were significant (p < 0.01). These analyses indicate a weak association between refractive error and higher-order aberrations in pre-school children.

23 February 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
DTDamber Thapa
Damber Thapa
RWRobert Welch
Robert Welch
RDRimple Poonia Dabas
Rimple Poonia Dabas
MSMohammahhossein Salimi
Mohammahhossein Salimi
PTPantea Tavakolian
Pantea Tavakolian
NTNima Tabatabaei
Nima Tabatabaei
The ability to detect dental caries at early stages lies at the heart of minimal intervention dentistry, enabling the curing or arresting of carious lesions before they advance to the cavity stage. Enhanced truncated-correlation photothermal coherence tomography (eTC-PCT) using mid-wave infrared (MWIR) cameras has recently been shown to offer tomographic visualization of early caries. The tomographic slicing ability of such systems, however, is believed to be limited by direct radiative thermal emission through the translucent dental enamel in the 3-5 µm MWIR spectral range. Such radiative emissions can dominate the delayed conductive thermal contributions needed for tomographic reconstruction of internal dental defects. It has been hypothesized that long-wave infrared (LWIR) eTC-PCT systems may offer better tomographic performance by taking advantage of the intrinsic attenuation of direct radiative emission by dental enamel in the LWIR spectral range, enabling more effective delayed conductive thermal contributions from subsurface caries. More than an order of magnitude lower cost of the system is another key attribute of LWIR eTC-PCT which can open the door for downstream translation of the technology to clinics. In this report, we offer a systematic comparison of the performance/effectiveness of caries detection with LWIR and MWIR eTC-PCT systems for detecting natural caries, bacterial caries, and artificially demineralized enamel surfaces. Our results suggest that the low-cost LWIR based eTC-PCT system provides 3D visualization and 2D slice-by-slice images of early caries and internal micro-cracks similar to those obtained from the more expensive MWIR-based eTC-PCT system, albeit with ∼1.3dB lower signal-to-noise ratio.