Patrice Tankam

Prof. Patrice Tankam


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Optics & Laser Technology
Verified
Journal Article
Closed access
RPRaju Poddar
Raju Poddar
PTPatrice Tankam
Patrice Tankam

1 February 2017 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
PTPatrice Tankam
Patrice Tankam
ATAyano Tanabe
Ayano Tanabe
NHNobuyuki Hashimoto
Nobuyuki Hashimoto
BCBarry Cense
Barry Cense
Optical coherence tomography (OCT) is a noninvasive, high-resolution optical imaging technique that is based on low coherence interferometry, and it is highly useful for generating cross-sectional images of turbid media. The first generation of OCT was in the time domain,1 with depth scan rates up to about 1 kHz, making it difficult to perform in vivo imaging of biological samples such as the human retina without motion artifacts. The introduction of Fourier-domain optical coherence tomography (FD-OCT) has improved the imaging speed and sensitivity over time-domain optical coherence tomography (TD-OCT).2,3 While the first spectral-domain OCT systems operated at depth scan rates of around 25 kHz, current systems can operate at speeds of 70 kHz or higher. High acquisition rates come with one penalty: the shorter acquisition time per depth scan causes a drop in sensitivity. To maintain image quality, one option is to increase the power that is incident on the sample. The ANSI safety rules for safe use of lasers limit the amount of light that can be sent into the eye.4 Another option to improve image quality is to increase the photon collection efficiency of the sample arm. This can be achieved by using a larger beam size than the ∼1.2-mm beam diameter that is used in the sample arm of standard OCT instruments. Merits of a larger beam size are a decreased speckle size and improved lateral resolution, which is limited by the diffraction limit set by the beam size, the focal length of the eye, and the wavelength of the light. While OCT permits independent control of its lateral and axial resolutions, an increased numerical aperture limits the confocal depth of the system, which affects the image quality at depths above and below the beam waist. Furthermore, with increasing beam diameter, the aberrations induced by the eye increase as well.5 To obtain these advantages and minimize the disadvantages caused by a large beam diameter, aberration correction is essential.

7 October 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
NJNomdo M. Jansonius
Nomdo M. Jansonius
JCJoel Cervantes
Joel Cervantes
PTPatrice Tankam
Patrice Tankam
BCBarry Cense
Barry Cense
Optical coherence tomography (OCT) images of the retina are inevitably affected by the finite width of the coherence function and noise. To make low-reflective layers visible, the raw OCT signal is log transformed; to reduce the effect of noise the images can be low-pass filtered. We determined the effects of these operations on layer thickness assessment, as a function of signal-to-noise ratio (SNR), by performing measurements in a phantom eye and modeling. The log transform appeared to be the key factor in a SNR-dependent overestimation of peak widths and a less predictive bias in the widths of low-reflective layers.

25 August 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
HPHadiya F. Pattan
Hadiya F. Pattan
XLXiao Liu
Xiao Liu
PTPatrice Tankam
Patrice Tankam
Non-invasive imaging systems with cellular-level resolution offer the opportunity to identify biomarkers of the early stage of corneal diseases, enabling early intervention, monitoring of disease progression, and evaluating treatment efficacy. In this study, a non-contact polarization-dependent optical coherence microscope (POCM) was developed to enable non-invasive in vivo imaging of human corneal microstructures. The system integrated quarter-wave plates into the sample and reference arms of the interferometer to enable deeper penetration of light in tissues as well as mitigate the strong specular reflection from the corneal surface. A common-path approach was adopted to enable control over the polarization in a free space configuration, thus alleviating the need for a broadband polarization-maintained fiber. The POCM achieved volumetric imaging of corneal microstructures, including endothelial cells over a field of view 0.5 × 0.5 mm2 with an almost isotropic resolution of ∼2.2 µm and a volume (500 × 500 × 2048 voxels) rate of 1 Hz. A self-interference approach between the corneal surface and underlying layers was also developed to lessen the corneal curvature and axial motion artifacts, thus enabling high-resolution imaging of microstructures in the anterior cornea, including squamous epithelial cells, wing epithelial cells, basal epithelial cells, sub-basal nerve plexus, and stromal keratocytes.

24 April 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
PTPatrice Tankam
Patrice Tankam
ZHZhiguo He
Zhiguo He
GTGilles Thuret
Gilles Thuret
HHHolly B. Hindman
Holly B. Hindman
CCCristina Canavesi
Cristina Canavesi
Jannick P. RollandJannick P. Rolland
Jannick P. Rolland
The cornea, the outermost window of our visual system, is made of five layers (from the anterior to the posterior cornea: the epithelium, the Bowman’s membrane, the stroma, the Descemet’s membrane (DM), and the endothelium). As a result, the cornea is easily accessible for imaging, although highly vulnerable to various types of infections and diseases—keratoconus (KC), Fuchs endothelial corneal dystrophy (FECD), pseudophakic bullous keratopathy (PBK), and lattice corneal dystrophy (LCD) to cite a few. The extremely large number of corneal diseases with unclear etiology and the almost impossibility of performing biopsies (except for the scraping of the epithelium) explain the need for high-performance imaging in order to optimize the clinical diagnosis. In addition, the cornea is the most commonly transplanted tissue worldwide with >40,000 transplants each year in the United States alone,1 and objective quality control of corneal grafts in eye banks mainly relies on corneal imaging. For instance, endothelial cell density (ECD) is a commonly used metric for evaluating the endothelial reserve, related to the capacity to maintain corneal transparency with time.