Recently, high strength steel and cold-formed steel are used on structural members, which have poor capacity for plastic strain. So there is a possibility that deformation capacity at the beam end is limited by not local buckling but brittle fracture. Because brittle fracture is brought on ductile crack, saving the occurrence of it lead to preventing brittle fracture. Purposes of this paper are to understand the initiation of ductile crack at the-notch tip by experiment, and to clarify the distribution of stress and strain at the notch section by FEM analysis. As a result, the criterion for ductile crack initiation is proposed.
In 2007, the American Iron and Steel Institute (AISI) established a standard for cold-formed steel–special bolted moment frames (CFS-SBMFs). This structural system is designed to resist seismic forces. The CFS-SBMF system employs double-channel beams and square hollow structural section (HSS) columns that are bolted together to create a sturdy and robust structural frame. However, the CFS-SBMF system is only suitable for constructing one-storey buildings, and ASCE 7 prohibits its use in buildings with a height of over one storey. This study was conducted to expand the use of CFS-SBMFs to the construction of multi-storey low-rise buildings. Firstly, a new moment connection detail is proposed, and a design procedure is proposed to ensure that bolted connections, instead of beams or columns, have the ductility to withstand seismic forces. Secondly, the proposed design procedure for bolted connections was verified through full-scale cyclic testing. Finally, a comprehensive evaluation was undertaken to evaluate the proposed structural system’s performance under seismic excitation. The evaluation included nonlinear dynamic analysis and incremental dynamic analysis (IDA) according to FEMA P695, which provided a detailed understanding of the seismic design factors (SDFs) in multi-storey low-rise CFS-SBMF buildings.
1 January 2017 in Journal of Structural and Construction Engineering (Transactions of AIJ)
Recommendation for Limit State Design of Steel Structure (LSD) specifies the requirements for columns to guarantee sufficient strength and ductility. However, the requirements stipulated in LSD are based on the monotonic test results that were conducted by H-shaped steel columns. It is necessary to confirm the elasto-plastic behavior of square steel tubular column under compressive axial force with cyclic bending moment. Also, it is important to compare the monotonic test results and the cyclic test results. In this study, testing where axial force with one end cyclic bending moment are applied to the column simultaneously are conducted. Moment capacity, deformation capacity and the second-order effects that will be caused by Pδ moment were evaluated from test results. Comparison with LSD requirements and comparison with monotonic test results were also shown.
1 January 2017 in Journal of Structural and Construction Engineering (Transactions of AIJ)
In Japan, square steel tubular columns are widely used. When the building is subject to a seismic load, columns will subject axial force with antisymmetric bending moment simultaneously. Therefore, it is important to design the column under these combined loading in the ultimate limit state to guarantee the safety. Recommendation for Limit State Design of Steel Structure (LSD) specifies the requirements for columns to guarantee sufficient strength and ductility. The plastic deformation capacity of the columns that are subjected to compressive axial force with one end monotonic bending moment are ensured more than 3 by LSD. However, specific deformation capacity of the column that are subjected to compressive axial force with monotonic antisymmetric bending moment is not shown. Test results that can confirm the appropriateness of LSD requirements for square steel tubular column are limited. It is necessary to gather more data of maximum strength, deformation capacity, and elasto-plastic behavior of square steel tubular columns by testing. Moreover, column that is subjected to compressive axial force is important to take into account second-order effects. In this study, testing where axial force with monotonic antisymmetric bending moment are applied to the columns simultaneously are conducted. Maximum bending moment, deformation capacity, and second-order effect that will be caused by Pδ moment were evaluated from the test results. Comparison between LSD requirements and test results were also shown. From the test results, followings are found. 1) Three types of collapse mechanism are confirmed. i) Local buckling occurred at one end of the column determined the ultimate state and deformation capacity. ii) Pδ moment determined the moment capacity at the loading point. After the maximum bending moment, local buckling occured at the maximum deflection point and it determined the ultimate state and deformation capacity. iii) Pδ moment determined the moment capacity at the loading point; increment of the bending deflection determined the ultimate state. Local buckling was not observed during the testing. 2) When the value of ny·λc02 is larger than 0.25, second-order effects determined the plastic deformation capacity. Plastic deformation capacity R of the columns that were determined by Pδ moment had a linear relation between ny·λc02. When the value of ny·λc02 is smaller than 0.25, plastic hinge was formed at the end of the column and determined the collapse mechanism. Width-to-Thickness ratio equals to 21.7 that was used in the testing and collapsed by local buckling had a plastic deformation capacity around 3.5. 3) Plastic deformation capacity of the square steel tubular column will be determined by either local buckling or Pδ moment. It was found that deformation capacity of the columns that were determined by Pδ effects have a linear relationship between ny·λc02; therefore, it is also important to evaluate quantitatively the plastic deformation capacity which is determined by local buckling. 4) Plastic deformation capacity greater than 3 were observed even if the current LSD limitation was not satisfied. However, from the point of view of collapse mechanism, LSD limitation can form a plastic hinge at the end of the column which is expected in design.
1 January 2018 in Journal of Structural and Construction Engineering (Transactions of AIJ)
In Japan, square steel tubular columns are widely used. When the building is under a seismic action, columns will be subjected to axial force with double curvature bending moment. Therefore, it is important to design the column under these combined loading in the ultimate limit state to guarantee the safety. Recommendation for Limit State Design of Steel Structure (LSD) and Recommendation for the Plastic Design of Steel Structures specify the requirements for column to guarantee sufficient strength and ductility. The plastic deformation capacity of the column that is subjected to compressive axial force with one end monotonic bending moment is ensured more than 3 by LSD. However, deformation capacity of the column that are subjected to compressive axial force with monotonic double curvature bending moment is not shown clearly. Test results that can confirm the appropriateness of LSD requirements for square steel tubular column are limited. It is necessary to gather more data of maximum strength, deformation capacity, and elasto-plastic behavior of square steel tubular columns by testing. Moreover, column that is subjected to compressive axial force is important to take into account second-order effects. In this study, testing where axial force with monotonic double curvature bending moment (end bending moment ratio equal to 0.5) are applied to the columns simultaneously are conducted. Maximum bending moment, plastic deformation capacity, and second-order effect that will be caused by Pδ moment were evaluated from the test results. Comparison between LSD requirements and test results were also shown. From the test results, followings are found. 1) Two types of collapse mechanism are confirmed. i) Local buckling occurred at one end of the column determined the ultimate state and deformation capacity. ii) Pδ moment determined the moment capacity at the loading point; increment of the bending deflection determined the ultimate state. Local buckling was not observed during the testing. 2) When the value of ny·λc02 is greater than 0.20, second-order effects determined the plastic deformation capacity. Plastic deformation capacity R of the columns that were determined by Pδ moment had a linear relation between ny·λc02. When the value of ny·λc02 is smaller than 0.17, plastic hinge was formed at the end of the column and determined the collapse mechanism. Nominal width-to-thickness ratio equals to 20.8 that was used in the testing had a plastic deformation capacity around 4.0 when it was determined by local buckling collapse. 3) Plastic deformation capacity greater than 3 were observed even if the current LSD limitation was not satisfied. However, from the point of view of collapse mechanism, LSD limitation can form a plastic hinge at the end of the column which is expected in design. 4) Even if moment amplification factor calculated by LSD is 1.0, the location of the maximum moment may appear in the middle of the column. i) ii)