Intraluminal aortic clamping has been achieved until now by means of a sophisticated device consisting of a three-lumen catheter named Endoclamp, which allows at the same time occlusion of the aorta, antegrade delivering of cardioplegia, and venting through the aortic root. This tool has shown important advantages allowing aortic occlusion and perfusate delivering without a direct contact with ascending aorta reducing meanwhile the risk of traumatic and/or iatrogenic injuries. Recently, a new device (Intraclude catheter) with the same characteristics and properties has been proposed and introduced in clinical practice. The aim of this paper is to investigate the differences between Endoclamp and Intraclude catheters and to analyze the advantages advocated by this new device for intraluminal aortic occlusion since it is noticeable as these new technological tools are gaining more and more attractiveness due to their appraised clinical efficacy.
29 December 2022 in European Journal of Cardio-Thoracic Surgery
OBJECTIVES: Over the past 20 years, valve-sparing aortic root replacement has aroused increasing interest because of a progressive attitude towards the preservation of natural tissue. Aortic reimplantation is the most used technique to spare the valve, allowing simultaneously aortic root replacement and aortic annular stabilization. The reimplantation into a graft with sinuses guarantees an optimal anatomic and functional reconstruction with established good results at 15 years. The aim of this study is to report the world longest follow-up (up to 20 years) of aortic valve reimplantation using the Valsalva graft.METHODS: From February 2000 to December 2021, 265 consecutive patients with aortic root aneurysm received aortic valve reimplantation using the Valsalva graft. From 2018, leaflet plication with the routine use of calliper was performed. For each patient, we performed both intraoperative and post-procedural transoesophageal echocardiography. All patients were followed with clinical assessment and echocardiography. The mean duration of follow-up was 85 ± 63 months.RESULTS: The study cohort had a median age of 55 ± 18 and 87.2% were male. The aortic root aneurysm was associated to bicuspid aortic valve in 18.9% of patients and to Marfan syndrome in 10.6% of cases. 55.9% had an aortic regurgitation ≥ 2+. Overall survival at 15 was 87.6 ± 3.4. Freedom from cardiac death was stable at 99.6 ± 0.4 at 5, 10 and 15 years. Freedom from recurrent AR ≥3+ and freedom from reoperation remained stable at 10 and 15 years at 92.2 ± 2.1 and 95.9 ± 1.6, respectively. There was a minimal incidence of infective endocarditis (0.8%), thromboembolism (2.2%) and haemorrhage (2.0%). Six out of 7 patients requiring reoperation had surgery in the first period of our experience (last in 2004). Early suboptimal results had a negative effect on residual aortic regurgitation. Moreover, we hypothesized that the routine use of calliper may have contributed to a further improvement of the outcome, even if these data need to be confirmed by a longer follow-up.CONCLUSIONS: The first long-term follow-up after aortic valve reimplantation using the Valsalva graft demonstrated excellent results. These long-term results gradually improved with learning curve, remaining stable during the second decade of observation. The systematic use of calliper may have contributed to a further improvement of the outcome.
11 March 2019 in European Journal of Cardio-Thoracic Surgery
OBJECTIVES: Aortic valve-sparing operations have been shown to produce fewer valve-related complications than valve replacement. The aortic root is a morphological and functional unit in which the annulus plays an important role on dynamism, shape and geometry of the valve with different results in bicuspid aortic valves (BAVs) or tricuspid aortic valves (TAVs). The aim is to evaluate the differences in the size and shape of the aortic annulus between native BAVs and TAVs using ECG-gated computed tomography (CT) after a reimplantation procedure. METHODS: We selected 35 patients scheduled for aortic valve reimplantation who underwent good-quality preoperative and postoperative ECG-gated contrast-enhanced CT scan of the aortic root. Twenty-three patients had TAV, 8 patients type 1 BAV and 4 patients type 0 BAV. Major diameter and minor diameter, perimeter (P) and area (A) were measured. The shape of the aortic annulus was considered ‘circular’ or ‘elliptic’ according to the Ellipticity Index. We also selected a subgroup of 18 patients (9 TAVs and 9 BAVs) to evaluate annular shape and size variations through the cardiac cycle and to study the expansibility both in the preoperative and in the postoperative phases. RESULTS: Preoperative CT scans showed an elliptic shape of TAVs (Ellipticity Index 1.3 ± 0.1), a circular shape of type 0 BAVs (1.1 ± 0.1) and an intermediate behaviour of type 1 BAVs, suggesting a possible gradual spectrum of circularity from TAVs to type 1 BAVs to type 0 BAVs. Postoperative CT scans did not show any significant difference in annular shape among the 3 groups, which demonstated a similar roundness, obviating the preoperative differences. Analysing the expansibility of the aortic annulus during the cardiac cycle, we observed that it was completely absent in the preoperative phase in BAVs, while in the postoperative phase, both TAVs and BAVs showed a small but similar expansibility after the annular reduction. CONCLUSIONS: There is a possible gradual spectrum in terms of shape, from native TAVs, to type 1 BAVS to type 0 BAVs. These differences are eliminated in the postoperative phase, suggesting an active role of the annuloplasty on the geometry of the aortic annulus. The preoperative analysis showed a complete inelasticity of BAVs, which was partly restored in the postoperative phase.
Epigenetic modifications play a fundamental role in the progression of coronary artery disease (CAD). This panoramic review aims to provide an overview of the current understanding of the epigenetic mechanisms involved in CAD pathogenesis and highlights the potential implications for personalized medicine approaches. Epigenetics is the study of heritable changes that do not influence alterations in the DNA sequence of the genome. It has been shown that epigenetic processes, including DNA/histone methylation, acetylation, and phosphorylation, play an important role. Additionally, miRNAs, lncRNAs, and circRNAs are also involved in epigenetics, regulating gene expression patterns in response to various environmental factors and lifestyle choices. In the context of CAD, epigenetic alterations contribute to the dysregulation of genes involved in inflammation, oxidative stress, lipid metabolism, and vascular function. These epigenetic changes can occur during early developmental stages and persist throughout life, predisposing individuals to an increased risk of CAD. Furthermore, in recent years, the concept of personalized medicine has gained significant attention. Personalized medicine aims to tailor medical interventions based on an individual’s unique genetic, epigenetic, environmental, and lifestyle factors. In the context of CAD, understanding the interplay between genetic variants and epigenetic modifications holds promise for the development of more precise diagnostic tools, risk stratification models, and targeted therapies. This review summarizes the current knowledge of epigenetic mechanisms in CAD and discusses the fundamental principles of personalized medicine.
Study Aim. Evaluation of results in blunt injury of the thoracic aorta (BAI) endovascular treatment.Materials and Methods. Sixteen patients were treated for BAI. Thirteen patients had associated polytrauma, 4 of these had a serious hypotensive status and 4 had an hemothorax. In the remaining 3, two had a post-traumatic false aneurysm of the isthmus and 1 had a segmental dissection. In those 13 patients a periaortic hematoma was associated to hemothorax in 4. All patients were submitted to an endovascular treatment, in two cases the subclavian artery ostium was intentionally covered.Results. One patient died for disseminated intravascular coagulation. No paraplegia was recorded. No ischemic complications were observed. A type I endoleak was treated by an adjunctive cuff. During the followup (1–9 years) 3 patients were lost. A good patency and no endoleaks were observed in all cases. One infolding and 1 migration of the endografts were corrected by an adjunctive cuff.Conclusion. The medium and long term results of the endovascular treatment of BAI are encouraging with a low incidence rate of mortality and complications. More suitable endo-suite and endografts could be a crucial point for the further improvement of these results.